Cited by 26Barrier Structure and Function StudiesCerebrospinal fluid and hydrocephalusClinical Laboratory Practices and Quality Control

Laser nephelometric evaluation of albumin, IgG and α2-macroglobulin: applications to the study of alterations of the blood-brain barrier

Meucci, Giuseppe, Rossi, Giulia, Bettini, Renato, Montanaro, Domenico, Gironelli, Luca, Voci, Loredana, Bianchi, Fabrizio·1993·Journal of the Neurological Sciences

Abstract

Cerebrospinal fluid and serum levels of albumin, immunoglobulin G and alpha 2-macroglobulin were determined by laser nephelometer in various pathological conditions: Guillain-Barré syndrome amyotrophic lateral sclerosis, lumbar disc herniation. These proteins are different due to their molecular weight, spacial conformation, CSF and serum concentrations and their CSF/serum quotient reflects the status of the blood-brain barrier. In the subjects group comparisons, albumin quotient and IgG quotient show a significant differentiations. The linear regression of albumin quotient compared to alpha 2-macroglobulin quotient behaves differently in the individual groups. The protein CSF/serum quotients are helpful in distinguishing the causes of alterations in the blood-brain barrier.

Integrity signals

Registry

Crossref · 10.1016/0022-510x(93)90248-w

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Increased Qalb values were found in 40% of all studied amyotrophic lateral sclerosis cases (55/138 from 4 independent studies).

    “increased Qalb values were found in 40% of all studied ALS cases (i.e., 55/138 from 4 independent studies) (23, 79, 407, 525)”

    From Blood-Brain Barrier: From Physiology to Disease and Back (2019) · cites this paper as [407]

Cited by

Sorted by citations

Authors
Meucci, G., Rossi, G., Bettini, R., Montanaro, D., Gironelli, L., Voci, L., & Bianchi, F.
Affiliations
  • University of Pisa (IT)
  • Istituto di Fisiologia Clinica (IT)
Corresponding author
Meucci, Giuseppe
Venue
Journal of the Neurological Sciences
Publisher
Elsevier BV
Published
1993-08
Volume
118
Issue
1
Pages
73-78
ISSN
0022-510X (ISSN-L)
OpenAlex
W2020550032
Cited by
26
References
0
Citations by year
2024: 2 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 1 · 2019: 1 · 2018: 1 · 2013: 1 · 2012: 5
FWCI
0.24
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of the Neurological Sciences (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Cerebrospinal fluid and hydrocephalus
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
Keywords
blood-brain barrier, cerebrospinal fluid, serum albumin, IgG, alpha2-macroglobulin, Guillain-Barré syndrome, amyotrophic lateral sclerosis, lumbar disc herniation, laser nephelometry
MeSH terms
Adolescent, Adult, Aged, Albumins, alpha-Macroglobulins, Amyotrophic Lateral Sclerosis, Blood-Brain Barrier, Brain Chemistry, Cerebrospinal Fluid Proteins, Female, Humans, Immunoglobulin G, Intervertebral Disc Displacement, Lasers, Male, Middle Aged, Nephelometry and Turbidimetry, Polyradiculoneuropathy, Regression Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review