Initial splanchnic extraction of ingested glucose in normal man
Abstract
Estimates of initial splanchnic uptake of ingested glucose and the concomitant suppression of endogenous glucose production were obtained in man by validated tracer techniques for non--steady-state turnover measurement. Nine normal volunteers (18--44 yr old) fasted overnight received intravenous infusions of tracer (3-3H-glucose or 1-14C-glucose) and a low (45 +/- 1 g) or high (96 +/- 5 g) oral load of glucose labeled with an alternative tracer (1-14C-glucose or 2-2H-glucose). A two-compartment model was used to derive rates of peripheral appearance (Ra) of glucose from all sources (total) and the Ra of ingested glucose. Ra (total glucose) and Ra (ingested glucose) were integrated from the first appearance of ingested glucose until the basal Ra (total glucose) or 116 +/- 6 (SEM) mg/min was reattained. The total amount of glucose reaching the systemic pool in this time was 95 +/- 4 g and 46 +/- 3 g with high and low doses, respectively. Of these quantities 86 +/- 4 g and 40 +/- 3 g originated in the oral glucose, representing 90% +/- 4% of the administered glucose. The remainder (11% +/- 2% of the total) represented endogenous production, suppressed by 66% +/- 6% relative to basal. Sequestration of ingested glucose and subsequent release did not take place during the study since identical results were obtained with ingested 1-14C-glucose or 2-3H-glucose. The latter label would have been lost if the glucose had entered the hexose--phosphate pool. Thus, in normal man approximate…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Isotopic measurements of glucose absorption of Radziuk et al. indicate that, for a 75-g glucose dose, glucose absorption is complete before 225 min.
“The isotopic measurements of glucose absorption of Radziuk et al. (23) indicate that, for a 75-g glucose dose, glucose absorption is complete before that time.”
The citation lists haven’t been fetched yet
References 37 · Cited by 207
- Authors
- Radziuk, J., McDonald, T. J., Rubenstein, D., & Dupre, J.
- Affiliations
- Royal Victoria Hospital (CA)
- Corresponding author
- Radziuk, J.
- ORCID
- McDonald, T.J.
- Venue
- Metabolism
- Publisher
- Elsevier BV
- Published
- 1978-06
- Volume
- 27
- Issue
- 6
- Pages
- 657-669
- ISSN
- 0026-0495 (ISSN-L)
- OpenAlex
- W1991454604
- Cited by
- 207
- References
- 37
- Citations by year
- 2023: 2 · 2021: 1 · 2020: 1 · 2017: 2 · 2016: 2 · 2015: 2 · 2014: 2 · 2013: 2 · 2012: 4
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Metabolism (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes, Cardiovascular Risks, and Lipoproteins
- Keywords
- glucose absorption, endogenous glucose production, glucose appearance rate, oral glucose tolerance, hepatic glucose metabolism
- MeSH terms
- Absorption, Adolescent, Adult, Digestive System, Dose-Response Relationship, Drug, Female, Glucose, Glucose Tolerance Test, Humans, Liver, Male, Mathematics, Middle Aged, Portal Vein
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review