The DOI matches its Crossref record.
The initial lymphatics as sensors of interstitial fluid volume
Abstract
Lymphatic luminal pressure and interstitial fluid pressure (IFP) were measured simultaneously in the bat's wing with two servo-null micropressure systems during interstitial fluid volume expansion induced by direct interstitial infusion. Lymphatic baseline pressure, pulsatile pressure, and IFP were elevated by the interstitial infusion. Transmural pressure gradients occurred only transiently. The increased lymphatic pulsatile pressure was not dependent upon the transmural pressure gradient but remained elevated as long as the increased interstitial fluid volume (IFV) was maintained. The results suggest that lymphatic pumping capacity during edema is modulated by IFV rather than IFP and that this mechanism may play an important role in the regulation of interstitial hydration. A mechanism whereby the initial lymphatics may directly sense and control IFV is proposed based upon physiological and anatomical data.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subsequent studies employing simultaneous measurements of pressures in the lymphatic capillary lumen and the interstitium showed that a favorable hydrostatic pressure gradient for reabsorption occurs transiently during the lymphatic contraction cycle when intraluminal pressure falls below interstitial pressure (30); this gradient provides the predominant driving force for reabsorption.”
From Transport and Immune Functions of the Lymphatic System. (2025) · cites this paper as [30]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 8
- Aukland, 1981, Interstitial fluid volume local regulatory mechanisms, Physiol. Rev., 61, 556, 10.1152/physrev.1981.61.3.556 · DOI
- Chen, 1976, Interaction of capillary, interstitial, and lymphatic forces in the canine hindpaw, Circ. Res., 39, 245, 10.1161/01.RES.39.2.245 · DOI
- Guyton, 1965, Interstitial fluid pressure. 11. Pressure-volume curves of interstitial space, Circ. Res., 16, 452, 10.1161/01.RES.16.5.452 · DOI
- Hargens, 1977, Contractile stimuli in collecting lymph vessels, Amer. J. Physiol., 233, H57
- Leak, 1970, Electron microscopic observations on lymphatic capillaries and the structural components of the connective tissue-lymph interface, Microvasc. Res., 2, 361, 10.1016/0026-2862(70)90031-2 · DOI
- Skalak, 1984, New morphological evidence for a mechanism of lymph formation in skeletal muscle, Microvasc. Res., 28, 95, 10.1016/0026-2862(84)90032-3 · DOI
- Wiedeman, 1973, Preparation of the bat wing for in vivo microscopy, Microvasc. Res., 5, 417, 10.1016/0026-2862(73)90058-7 · DOI
- Zweifach, 1979, The interstitial-lymphatic flow system, Vol. 18, 215
Cited by
Sorted by citations
Transport and Immune Functions of the Lymphatic System.
Davis, M. J., Zawieja, S. D., & King, P. D. (2025) · Annual Review of Physiology · doi:10.1146/annurev-physiol-022724-104908 · Cited by 42
Metadata
- Authors
- Hogan, R. D., & Unthank, J. L.
- Affiliations
- Indiana University Indianapolis (US)
- Venue
- Microvascular Research
- Publisher
- Elsevier BV
- Published
- 1986-05
- Volume
- 31
- Issue
- 3
- Pages
- 317-324
- ISSN
- 0026-2862 (ISSN-L)
- OpenAlex
- W2063305546
- Cited by
- 40
- References
- 0
- Citations by year
- 2025: 1 · 2024: 3 · 2023: 1 · 2022: 1 · 2021: 1 · 2017: 2 · 2012: 2
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Microvascular Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Oncology › Lymphatic System and Diseases
- Health Sciences › Medicine › Surgery › Lymphatic Disorders and Treatments
- Health Sciences › Medicine › Infectious Diseases › Parasitic Diseases Research and Treatment
- Keywords
- initial lymphatics, interstitial fluid volume, interstitial fluid pressure, lymphatic pressure, edema, bat wings
- MeSH terms
- Animals, Chiroptera, Extracellular Space, Lymph, Pressure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review