Geometric factor and directional response of single and multi-element particle telescopes
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Precise Measurement of Cosmic‐Ray Proton and Helium Spectra with the BESS Spectrometer
Sanuki, T., Motoki, M., Matsumoto, H., Seo, E. S., Wang, J. Z., Abe, K., Anraku, K., Asaoka, Y., Fujikawa, M., Imori, M., et al. (2000) · The Astrophysical Journal · doi:10.1086/317873 · Cited by 314
Cosmic-ray positron fraction measurement from 1 to 30 GeV with AMS-01
Aguilar, M., Alcaraz, J., Allaby, J., Alpat, B., Ambrosi, G., Anderhub, H., Ao, L., Arefiev, A., Azzarello, P., Baldini, L., et al. (2007) · Physics Letters B · doi:10.1016/j.physletb.2007.01.024 · Cited by 310
Ginet, G. P., O’Brien, T. P., Huston, S. L., Johnston, W. R., Guild, T. B., Friedel, R., Lindstrom, C. D., Roth, C. J., Whelan, P., Quinn, R. A., et al. (2013) · Space Science Reviews · doi:10.1007/s11214-013-9964-y · Cited by 300
Measurements of primary and atmospheric cosmic-ray spectra with the BESS-TeV spectrometer
Haino, S., Sanuki, T., Abe, K., Anraku, K., Asaoka, Y., Fuke, H., Imori, M., Itasaki, A., Maeno, T., Makida, Y., et al. (2004) · Physics Letters B · doi:10.1016/j.physletb.2004.05.019 · Cited by 268
Neutron Monitor Response Functions
Clem, J. M., & Dorman, L. I. (2000) · Space Science Reviews · doi:10.1023/a:1026508915269 · Cited by 253
The Cosmic‐Ray Electron and Positron Spectra Measured at 1 AU during Solar Minimum Activity
Boezio, M., Carlson, P., Francke, T., Weber, N., Suffert, M., Hof, M., Menn, W., Simon, M., Stephens, S. A., Bellotti, R., et al. (2000) · The Astrophysical Journal · doi:10.1086/308545 · Cited by 252
The Energetic Particle Detector: Energetic particle instrument suite for the Solar Orbiter mission
Rodríguez-Pacheco, J., Wimmer-Schweingruber, R. F., Mason, G. M., Ho, G. C., Sánchez-Prieto, S., Prieto, M., Martín, C., Seifert, H., Andrews, G. B., Kulkarni, S. R., et al. (2020) · Astronomy & Astrophysics · doi:10.1051/0004-6361/201935287 · Cited by 219
“Geometric factors of HET are calculated analytically using the method given in Sullivan (1971) for two circular detectors.”
MethodNeutron Monitor Response Functions
Clem, J. M., & Dorman, L. I. (2000) · Space Sciences Series of ISSI · doi:10.1007/978-94-017-1187-6_16 · Cited by 217
The Cosmic‐Ray Proton and Helium Spectra between 0.4 and 200 GV
Boezio, M., Carlson, P., Francke, T., Weber, N., Suffert, M., Hof, M., Menn, W., Simon, M., Stephens, S. A., Bellotti, R., et al. (1999) · The Astrophysical Journal · doi:10.1086/307251 · Cited by 213
“Furthermore, the detector efficiencies, the geometrical factor (G), obtained with simulation techniques (Sullivan 1971), and the total live time have to be taken into account.”
MethodYando, K., Millan, R. M., Green, J. C., & Evans, D. S. (2011) · Journal of Geophysical Research: Space Physics · doi:10.1029/2011ja016671 · Cited by 205
Shikaze, Y., Haino, S., Abe, K., Fuke, H., Hams, T., Kim, K. C., Makida, Y., Matsuda, S., Mitchell, J. W., Moiseev, A. A., et al. (2007) · Astroparticle Physics · doi:10.1016/j.astropartphys.2007.05.001 · Cited by 202
The Cosmic‐Ray Antiproton Flux between 3 and 49 GeV
Boezio, M., Bonvicini, V., Schiavon, P., Vacchi, A., Zampa, N., Bergstrom, D., Carlson, P., Francke, T., Grinstein, S., Suffert, M., et al. (2001) · The Astrophysical Journal · doi:10.1086/323366 · Cited by 190
“The geometrical factor was obtained with Monte Carlo techniques (Sullivan 1971) and the same track-fitting algorithm used in this analysis to trace the particles through the spectrometer.”
MethodThe PAMELA Mission: Heralding a new era in precision cosmic ray physics
Adriani, O., Barbarino, G. C., Bazilevskaya, G. A., Bellotti, R., Boezio, M., Bogomolov, E. A., Bongi, M., Bonvicini, V., Bottai, S., Bruno, A., et al. (2014) · Physics Reports · doi:10.1016/j.physrep.2014.06.003 · Cited by 186
Semkova, J., Koleva, R., Benghin, V., Dachev, T., Matviichuk, Y., Tomov, B., Krastev, K., Maltchev, S., Dimitrov, P., Mitrofanov, I., et al. (2018) · Icarus · doi:10.1016/j.icarus.2017.12.034 · Cited by 64
Ginet, G. P., O’Brien, T. P., Huston, S. L., Johnston, W. R., Guild, T. B., Friedel, R., Lindstrom, C. D., Roth, C. J., Whelan, P., Quinn, R. A., et al. (2013) · The Van Allen Probes Mission · doi:10.1007/978-1-4899-7433-4_18 · Cited by 56
Wimmer‐Schweingruber, R. F., Köhler, J., Hassler, D. M., Guo, J., Appel, J., Zeitlin, C., Böhm, E., Ehresmann, B., Lohf, H., Böttcher, S. I., et al. (2015) · Geophysical Research Letters · doi:10.1002/2015gl066664 · Cited by 28
“Including the projection onto a zenith-pointing plane detector of unit area, the thus normalized counts are given by dn = dΩ cos(𝜃) dA = cos(𝜃) sin(𝜃) d𝜃 d𝜙 dA, (1) where dA is the differential area of the detector and cos(𝜃) accounts for the projection effect [Sullivan, 1971].”
BackgroundMethodNarici, L., Berger, T., Burmeister, S., Di Fino, L., Rizzo, A., Matthiä, D., & Reitz, G. (2017) · Journal of Space Weather and Space Climate · doi:10.1051/swsc/2017016 · Cited by 13
“The double-directional Geometrical Factor (GF) is 230 cm2 sr (calculated from our Monte Carlo – PHITS (Particle and Heavy Ion Transport code System) ALTEA model, and consistent with Sullivan 1971).”
Method
Metadata
- Authors
- Sullivan, J. D.
- Venue
- Nuclear Instruments and Methods
- Publisher
- Elsevier BV
- Published
- 1971-08
- Volume
- 95
- Issue
- 1
- Pages
- 5-11
- ISSN
- 0029-554X (ISSN-L)
- OpenAlex
- W2013178394
- Cited by
- 223
- References
- 0
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.