Performance of direct contact latent heat storage units with two hydrated salts
The DOI matches its Crossref record.
Abstract
The performance of a direct contact latent heat storage unit, that consists of two columns with differnet hydrated salts, has been investigated. Na2CO3·10H2O (sodium carbonate decahydrate) and Na2S2O3·5H2O (sodium thiosulphate pentahydrate) were contained in separate columns both having an inside diameter and total length of 0.184 m and 1.0 m, respectively. During heat charge, the hot kerosene as a heat transfer fluid was bubbled through the sodium thiosulfate solution first. The partially cooled kerosene was then pumped to the second column containing the sodium carbonate solution, discharging most of its heat content. Flow direction was reversed during heat discharge. The continuous phase temperature in the two columns, as well as kerosene inlet and outlet temperatures, were measured continuously. Results showed significant improvement in heat transfer rates by using two separate columns containing similar or different salts. The use of a combination of two different salts, having different crystallization temperatures, and contained in different columns connected in series, may provide better means of heat storage by allowing the system to operate as a phase change storage for longer periods of operation. This is particularly suitable for solar energy applications in which the collector temperature may vary significantly during the day.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review on phase change energy storage: materials and applications
Farid, M. M., Khudhair, A. M., Razack, S. A. K., & Al-Hallaj, S. (2004) · Energy Conversion and Management · doi:10.1016/j.enconman.2003.09.015 · Cited by 3,097
Self-citationReview on phase change materials (PCMs) for cold thermal energy storage applications
Oró, E., de Gracia, A., Castell, A., Farid, M. M., & Cabeza, L. F. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.03.058 · Cited by 1,144
Self-citationA review of potential materials for thermal energy storage in building applications
Tatsidjodoung, P., Le Pierrès, N., & Luo, L. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.10.025 · Cited by 643
Cárdenas, B., & León, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.07.028 · Cited by 496
Thermal energy storage in district heating and cooling systems: A review
Guelpa, E., & Verda, V. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113474 · Cited by 471
Metadata
- Authors
- Farid, M. M., & Khalaf, A. N.
- Venue
- Solar Energy
- Publisher
- Elsevier BV
- Published
- 1994-02
- Volume
- 52
- Issue
- 2
- Pages
- 179-189
- ISSN
- 0038-092X (ISSN-L)
- OpenAlex
- W1975240629
- Cited by
- 44
- References
- 0
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of direct contact latent heat storage units with two hydrated salts. https://app.cochat.ai/papers/10.1016/0038-092x(94)90067-1
- The paper
- Farid, M. M., & Khalaf, A. N. (1994). Performance of direct contact latent heat storage units with two hydrated salts. Solar Energy. https://doi.org/10.1016/0038-092x(94)90067-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.