The DOI matches its Crossref record.
Evaluation of biomaterials: Ed. G.D. Winter, J. Leray and K. de Groot John Wiley and Sons, Chichester, 1980 xxi + 553, £45
Abstract
Hydroxyapatite (HAp)–carbon nanotube (CNT) composites are being fabricated, where CNT acts as a reinforcement in the ceramic matrix. CNT improves the mechanical property of HAp and offers a potential implant material used for orthopaedic applications. In the present work, a comparative study is presented to analyse the effect of functionalisation on the properties of HAp–CNT nanocomposites, prepared by a simple shear mixing technique. The MWCNT chains were functionalised with carboxyl groups, confirmed through FTIR spectra. FESEM and TEM results of the composites showed that for non-functionalised chains, CNT molecules were present in sporadic clusters while the functionalised chains were found to be dispersed in the HAp matrix. Fractographs exhibited the presence of CNT chains acting as bridges across the cracks. Nanocomposites with functionalised CNT molecules exhibited better mechanical properties compared to non-functionalised ones as revealed through HV, K1c, nano-indentation H and E estimation, flexural and compressive strength and impact resistance. This superiority of composite specimens may be attributed to the crack bridging action of the CNT. Both composites exhibited excellent haemocompatibility and incorporation of CNT molecules and functionalisation did not affect this.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
Biomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Biodegradation and bioresorption of calcium phosphate ceramics
LeGeros, R. Z. (1993) · Clinical Materials · doi:10.1016/0267-6605(93)90049-d · Cited by 647
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Metadata
- Authors
- Hostings, G. W.
- Venue
- Journal of Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 1981-01-01
- Volume
- 3
- Issue
- 1
- Pages
- 76a-76
- ISSN
- 0141-5425 (ISSN-L)
- OpenAlex
- W310150040
- Cited by
- 253
- References
- 0
- FWCI
- 10.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of biomaterials: Ed. G.D. Winter, J. Leray and K. de Groot John Wiley and Sons, Chichester, 1980 xxi + 553, £45. https://app.cochat.ai/papers/10.1016/0141-5425(81)90116-3
- The paper
- Hostings, G. W. (1981). Evaluation of biomaterials: Ed. G.D. Winter, J. Leray and K. de Groot John Wiley and Sons, Chichester, 1980 xxi + 553, £45. Journal of Biomedical Engineering. https://doi.org/10.1016/0141-5425(81)90116-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.