CoChat

Ultrasonic measurement of human fetal blood flow

Eik-Nes, Sturla H., Marsal, Karel, Brubakk, Alf O., Kristofferson, Kjell, Ulstein, Magnar · 1982 · Journal of Biomedical Engineering
Cited by 157

The DOI matches its Crossref record.

Abstract

Pulsed Doppler technique was combined with real-time B-mode ultrasonography for non-invasive measurement of human fetal blood flow in utero. The fetal vessel, e.g. aorta or umbilical vein, was identified in the real-time image and the real-time transducer put parallel to the vessel. The 2 MHz pulsed Doppler transducer insonated the vessel at a known angle, as the transducers were firmly attached to each other at an angle of 52 degrees. The Doppler instrument processed the Doppler shift signals and estimated the mean and maximum blood velocity. For calculation of blood flow, fetal vessel diameter must be measured. Three ultrasonic techniques (real-time B-mode, TM-mode, Time-distance recording) were applied for diameter measurements. The accuracy of the real-time B-mode technique was tested in vitro on 8 glass tubes with various diameters; the ultrasonically measured diameter was within +/- 0.4 mm of the diameter measured with vernier calipers. The reproducibility of diameter measurement was tested in vivo; the standard deviation of the difference between measurement was 0.15 mm for the fetal aorta and 0.20 mm for the umbilical vein. Fetal blood flow was measured in 38 normal late pregnancies. Blood flow in the thoracic part of the descending fetal aorta ws 185 ml min-1 kg-1 when based on mean blood velocity, and 261 ml min-1 kg-1 when based on maximum blood velocity. In the intra-abdominal part of the umbilical vein the mean blood flow was 115 ml min-1 kg-1.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0141-5425(82)90023-1

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 157

Metadata

Authors
Eik-Nes, S. H., Marsal, K., Brubakk, A. O., Kristofferson, K., & Ulstein, M.
Venue
Journal of Biomedical Engineering
Published
1982-01-01
Volume
4
Issue
1
Pages
28-36
ISSN
0141-5425 (ISSN-L)
OpenAlex
W2016333043
Cited by
157
References
0
FWCI
14.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasonic measurement of human fetal blood flow. https://app.cochat.ai/papers/10.1016/0141-5425(82)90023-1
The paper
Eik-Nes, S. H., Marsal, K., Brubakk, A. O., Kristofferson, K., & Ulstein, M. (1982). Ultrasonic measurement of human fetal blood flow. Journal of Biomedical Engineering. https://doi.org/10.1016/0141-5425(82)90023-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.