Ultrasonic measurement of human fetal blood flow
The DOI matches its Crossref record.
Abstract
Pulsed Doppler technique was combined with real-time B-mode ultrasonography for non-invasive measurement of human fetal blood flow in utero. The fetal vessel, e.g. aorta or umbilical vein, was identified in the real-time image and the real-time transducer put parallel to the vessel. The 2 MHz pulsed Doppler transducer insonated the vessel at a known angle, as the transducers were firmly attached to each other at an angle of 52 degrees. The Doppler instrument processed the Doppler shift signals and estimated the mean and maximum blood velocity. For calculation of blood flow, fetal vessel diameter must be measured. Three ultrasonic techniques (real-time B-mode, TM-mode, Time-distance recording) were applied for diameter measurements. The accuracy of the real-time B-mode technique was tested in vitro on 8 glass tubes with various diameters; the ultrasonically measured diameter was within +/- 0.4 mm of the diameter measured with vernier calipers. The reproducibility of diameter measurement was tested in vivo; the standard deviation of the difference between measurement was 0.15 mm for the fetal aorta and 0.20 mm for the umbilical vein. Fetal blood flow was measured in 38 normal late pregnancies. Blood flow in the thoracic part of the descending fetal aorta ws 185 ml min-1 kg-1 when based on mean blood velocity, and 261 ml min-1 kg-1 when based on maximum blood velocity. In the intra-abdominal part of the umbilical vein the mean blood flow was 115 ml min-1 kg-1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
“forthee....towhom% nosoundisdissonantwhichtellsoflife”% —coleridge
McNay, M., & Fleming, J. E. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00129-x · Cited by 425
Umbilical artery velocity waveforms and intrauterine growth retardation
Fleischer, A., Schulman, H., Farmakides, G., Bracero, L., Blattner, P., & Randolph, G. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90278-9 · Cited by 270
Methodology and basic problems related to blood flow studies in the human fetus
Eik-Nes, S. H., Maršál, K., & Kristoffersen, K. (1984) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(84)90167-4 · Cited by 194
Self-citationFetal cardiac output estimated by Doppler echocardiography during mid- and late gestation
De Smedt, M. C. H., Visser, G. H. A., & Meijboom, E. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90238-4 · Cited by 181
Measurement of arterial blood flow by Doppler ultrasound
Hoskins, P. R. (1990) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/11/1/001 · Cited by 109
Metadata
- Authors
- Eik-Nes, S. H., Marsal, K., Brubakk, A. O., Kristofferson, K., & Ulstein, M.
- Venue
- Journal of Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 1982-01-01
- Volume
- 4
- Issue
- 1
- Pages
- 28-36
- ISSN
- 0141-5425 (ISSN-L)
- OpenAlex
- W2016333043
- Cited by
- 157
- References
- 0
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasonic measurement of human fetal blood flow. https://app.cochat.ai/papers/10.1016/0141-5425(82)90023-1
- The paper
- Eik-Nes, S. H., Marsal, K., Brubakk, A. O., Kristofferson, K., & Ulstein, M. (1982). Ultrasonic measurement of human fetal blood flow. Journal of Biomedical Engineering. https://doi.org/10.1016/0141-5425(82)90023-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.