The DOI matches its Crossref record.
Pendulum testing of spasticity
Abstract
Simple and inexpensive instrumentation required for pendulum testing of spasticity is described. It is based on the use of an electrogoniometer and tachometer. Eight parameters are extracted from the goniogram and the tachogram to evaluate the degree of spasticity. The correlation coefficients are calculated to determine the parameters relevant for the estimation of spasticity. Spasticity was assessed in the knee extensors of ten spinal cord injury patients and in five hemiplegics. The described instrumentation and evaluation of the pendulum test provide an effective spasticity testing in the clinical environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Understanding and measurement of muscle tone as related to clinical muscle pain
Simons, G. D., & Mense, S. (1998) · Pain · doi:10.1016/s0304-3959(97)00102-4 · Cited by 353
Objective quantification of spastic hypertonia: Correlation with clinical findings
Katz, R. T., Rovai, G. P., Brait, C., & Rymer, W. Z. (1992) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(92)90007-j · Cited by 314
Kim, Y.-W. (2013) · Journal of Physical Therapy Science · doi:10.1589/jpts.25.1279 · Cited by 9
Metadata
- Authors
- Bajd, T., & Vodovnik, L.
- Venue
- Journal of Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 1984-01-01
- Volume
- 6
- Issue
- 1
- Pages
- 9-16
- ISSN
- 0141-5425 (ISSN-L)
- OpenAlex
- W2040017350
- Cited by
- 219
- References
- 0
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pendulum testing of spasticity. https://app.cochat.ai/papers/10.1016/0141-5425(84)90003-7
- The paper
- Bajd, T., & Vodovnik, L. (1984). Pendulum testing of spasticity. Journal of Biomedical Engineering. https://doi.org/10.1016/0141-5425(84)90003-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.