Pulsatile non-newtonian blood flow in three-dimensional carotid bifurcation models: a numerical study of flow phenomena under different bifurcation angles
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Flow and stress patterns in human carotid artery bifurcation models, which differ in the bifurcation angle, are analysed numerically under physiologically relevant flow conditions. The governing Navier-Stokes equations describing pulsatile, three-dimensional flow of an incompressible non-Newtonian fluid are approximated using a pressure correction finite element method, which has been developed recently. The non-Newtonian behaviour of blood is modelled using Casson's relation, based on measured dynamic viscosity. The study concentrates on flow and stress characteristics in the carotid sinus. The results show that the complex flow in the sinus is affected by the angle variation. The magnitude of reversed flow, the extension of the recirculation zone in the outer sinus region and the duration of flow separation during the pulse cycle as well as the resulting wall shear stress are clearly different in the small angle and in the large angle bifurcation. The haemodynamic phenomena, which are important in atherogenesis, are more pronounced in the large angle bifurcation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707
Zarins, C. K., Giddens, D. P., Bharadvaj, B. K., Sottiurai, V. S., Mabon, R. F., & Glagov, S. (1983) · Circulation Research · doi:10.1161/01.res.53.4.502 · Cited by 1,485
Caro, C. G., Fitz-Gerald, J. M., & Schroter, R. C. (1971) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1971.0019 · Cited by 1,357
Steady flow in a model of the human carotid bifurcation. Part I—Flow visualization
Bharadvaj, B. K., Mabon, R. F., & Giddens, D. P. (1982) · Journal of Biomechanics · doi:10.1016/0021-9290(82)90057-4 · Cited by 315
Flow patterns in the human carotid artery bifurcation.
Motomiya, M., & Karino, T. (1984) · Stroke · doi:10.1161/01.str.15.1.50 · Cited by 254
Pulsatile flow in a model carotid bifurcation.
Ku, D. N., & Giddens, D. P. (1983) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.3.1.31 · Cited by 236
Perktold, K., Resch, M., & Peter, R. O. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90029-m · Cited by 220
Self-citationLaser Doppler anemometer measurements of pulsatile flow in a model carotid bifurcation
Ku, D. N., & Giddens, D. P. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90048-0 · Cited by 130
Laser Doppler anemometer measurements of pulsatile flow in a model carotid bifurcation
Blackshear, W. M. (1988) · Journal of Vascular Surgery · doi:10.1016/0741-5214(88)90029-8 · Cited by 94
Cited by
Finite element modeling of blood flow in arteries
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1998) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(98)80008-x · Cited by 726
Perktold, K., & Rappitsch, G. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)95273-8 · Cited by 493
Self-citationHemodynamics of Cerebral Aneurysms
Sforza, D. M., Putman, C. M., & Cebral, J. R. (2009) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102126 · Cited by 466
Peiffer, V., Sherwin, S. J., & Weinberg, P. D. (2013) · Cardiovascular Research · doi:10.1093/cvr/cvt044 · Cited by 379
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1998) · Annals of Biomedical Engineering · doi:10.1114/1.140 · Cited by 373
A Framework for Geometric Analysis of Vascular Structures: Application to Cerebral Aneurysms
Piccinelli, M., Veneziani, A., Steinman, D. A., Remuzzi, A., & Antiga, L. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2021652 · Cited by 346
Les, A. S., Shadden, S. C., Figueroa, C. A., Park, J. M., Tedesco, M. M., Herfkens, R. J., Dalman, R. L., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9949-x · Cited by 314
E XPERIMENTAL AND C OMPUTATIONAL M ETHODS IN C ARDIOVASCULAR F LUID M ECHANICS
Taylor, C. A., & Draney, M. T. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121944 · Cited by 285
Atherosclerosis at arterial bifurcations: evidence for the role of haemodynamics and geometry
Morbiducci, U., Kok, A. M., Kwak, B. R., Stone, P. H., Steinman, D. A., & Wentzel, J. J. (2016) · Thrombosis and Haemostasis · doi:10.1160/th15-07-0597 · Cited by 258
Pathological Findings at Bifurcation Lesions
Nakazawa, G., Yazdani, S. K., Finn, A. V., Vorpahl, M., Kolodgie, F. D., & Virmani, R. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.01.021 · Cited by 257
Predictive medicine: Computational techniques in therapeutic decision-making
Taylor, C. A., Draney, M. T., Ku, J. P., Parker, D., Steele, B. N., Wang, K., & Zarins, C. K. (1999) · Computer Aided Surgery · doi:10.1002/(sici)1097-0150(1999)4:5<231::aid-igs1>3.0.co;2-z · Cited by 257
Introductory biomechanics: from cells to organisms
(2007) · Choice Reviews Online · doi:10.5860/choice.45-1476 · Cited by 241
Elevated heart rate and atherosclerosis: An overview of the pathogenetic mechanisms
Giannoglou, G. D., Chatzizisis, Y. S., Zamboulis, C., Parcharidis, G. E., Mikhailidis, D. P., & Louridas, G. E. (2008) · International Journal of Cardiology · doi:10.1016/j.ijcard.2007.08.077 · Cited by 235
“Human in vivo data revealed that the average curvature of the left anterior descending artery exhibits its highest values in systole, whereas relatively low and constant curvature occurs in diastole [89] (Fig.”
BackgroundMarkl, M., Wegent, F., Zech, T., Bauer, S., Strecker, C., Schumacher, M., Weiller, C., Hennig, J., & Harloff, A. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.110.958504 · Cited by 232
Predictive Medicine: Computational Techniques in Therapeutic Decision-Making
Taylor, C. A., Draney, M. T., Ku, J. P., Parker, D., Steele, B. N., Wang, K., & Zarins, C. K. (1999) · Computer Aided Surgery · doi:10.3109/10929089909148176 · Cited by 221
Shape optimization in steady blood flow: A numerical study of non-Newtonian effects
Abraham, F., Behr, M., & Heinkenschloss, M. (2005) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840500180799 · Cited by 182
“Gijsen et al. (1999) show higher differences in the axial velocity profile compared to results obtained by Perktold et al. (1991) for a 3D carotid bifurcation study when using Computer Methods in Biomechanics and Biomedical Engineering ISSN 1025-5842 print/ISSN 1476-8259 online q 2005 Taylor &…”
ResultValidated computation of physiologic flow in a realistic coronary artery branch
Perktold, K., Hofer, M., Rappitsch, G., Loew, M., Kuban, B. D., & Friedman, M. H. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00118-8 · Cited by 182
“In our earlier e⁄ort to examine the hemodynamic consequences of variations in arterial geometry, the flow fields in four three-dimensional idealized carotid artery bifurcations were computed, and significant influence was found (Perktold and Resch, 1990; Perktold et al., 1991a ).”
MethodSelf-citationEffect of exercise on hemodynamic conditions in the abdominal aorta
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1999) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(99)70249-1 · Cited by 177
Metadata
- Authors
- Perktold, K., Peter, R. O., Resch, M., & Langs, G.
- Venue
- Journal of Biomedical Engineering
- Publisher
- IOP Publishing
- Published
- 1991-11-01
- Volume
- 13
- Issue
- 6
- Pages
- 507-515
- ISSN
- 0141-5425 (ISSN-L)
- OpenAlex
- W1982825509
- Cited by
- 211
- References
- 9
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.