The indoor air quality in Finnish homes with mold problems
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While the health problems in moldy buildings are associated with exposure to high concentrations of airborne fungal spores in a few studies (42, 58), several field studies show that the fungal spore concentration in problem buildings is not necessarily higher than that in nonproblem ones (14, 25, 36, 53).”
From Fungal Fragments as Indoor Air Biocontaminants (2002) · cites this paper as [36]
Citations
Cites
Damp housing, mould growth, and symptomatic health state.
Platt, S. D., Martin, C. J., Hunt, S. M., & Lewis, C. W. (1989) · BMJ · doi:10.1136/bmj.298.6689.1673 · Cited by 457
Pasanen, A. ‐., Kalliokoski, P., Pasanen, P. O., Jantunen, M. J., & Nevalainen, A. I. (1991) · Environment International · doi:10.1016/0160-4120(91)90006-c · Cited by 132
Self-citationBioaerosol and particle mass levels and ventilation in finnish homes
Reponen, T. A., Nevalainen, A. I., & Raunemaa, T. M. (1989) · Environment International · doi:10.1016/0160-4120(89)90028-7 · Cited by 51
Self-citationImproved techniques for sampling airborne fungal particles in highly contaminated environments.
Blomquist, G., Palmgren, U., & Strom, G. (1984) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.2334 · Cited by 36
Research works printed but not linked: 1
- Jantunen, 1987, The effect of humidification on indoor air fungal spores counts in apartment buildings, Vol. 1, 643
Cited by
Bacterial volatiles: the smell of small organisms
Schulz, S., & Dickschat, J. S. (2007) · Natural Product Reports · doi:10.1039/b507392h · Cited by 892
The health effects of nonindustrial indoor air pollution
Bernstein, J. A., Alexis, N., Bacchus, H., Bernstein, I. L., Fritz, P., Horner, E., Li, N., Mason, S., Nel, A., Oullette, J., et al. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.10.045 · Cited by 574
“In addition to mold, yeasts, wood-rotting fungi, and bacteria can grow in moist building materials.(54) Furthermore, dampness can damage building materials and furnishings, leading to offgassing of chemicals (eg, formaldehyde) and release of nonbiological particles.”
BackgroundSelf-citationGarrett, Rayment, Hooper, Abramson, & Hooper (1998) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2222.1998.00255.x · Cited by 410
Fungal Fragments as Indoor Air Biocontaminants
Górny, R. L., Reponen, T., Willeke, K., Schmechel, D., Robine, E., Boissier, M., & Grinshpun, S. A. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.7.3522-3531.2002 · Cited by 402
“While the health problems in moldy buildings are associated with exposure to high concentrations of airborne fungal spores in a few studies (42, 58), several field studies show that the fungal spore concentration in problem buildings is not necessarily higher than that in nonproblem ones (14, 25, 36, 53).”
BackgroundSelf-citation(2005) · Choice Reviews Online · doi:10.5860/choice.42-4060 · Cited by 372
“gators found no differences between airborne spore concentrations (Dill and Niggeman, 1996; Garrett et al., 1998; Nevalainen et al., 1991; Pasanen et al., 1992; Strachen et al., 1990).”
BackgroundBacterial and fungal aerosol in indoor environment in Upper Silesia, Poland
Pastuszka, J. S., Kyaw Tha Paw, U., Lis, D. O., Wlazło, A., & Ulfig, K. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00527-0 · Cited by 318
Diversity and seasonal dynamics of bacterial community in indoor environment
Rintala, H., Pitkaranta, M., Toivola, M., Paulin, L., & Nevalainen, A. (2008) · BMC Microbiology · doi:10.1186/1471-2180-8-56 · Cited by 291
“To date, the sole bacterial group that has been associated with moisture damage is the group of spore-forming actinomycetes [46,47].”
BackgroundSelf-citationFrankel, M., Bekö, G., Timm, M., Gustavsen, S., Hansen, E. W., & Madsen, A. M. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.02069-12 · Cited by 287
“This is in accordance with various studies showing no clear relationship between visible fungal growth and the level of airborne microbial exposure (34, 44, 49).”
ResultIdentification of volatile metabolites from five fungal species cultivated on two media
Sunesson, A., Vaes, W., Nilsson, C., Blomquist, G., Andersson, B., & Carlson, R. (1995) · Applied and Environmental Microbiology · doi:10.1128/aem.61.8.2911-2918.1995 · Cited by 224
“(24), airborne spore counts may be low even in rooms where fungal growth is clearly visible, because fungi do not sporulate continuously (15, 28).”
BackgroundSignificance of air humidity and air velocity for fungal spore release into the air
Pasanen, A.-L., Pasanen, P., Jantunen, M. J., & Kalliokoski, P. (1991) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(91)90316-y · Cited by 191
Self-citationMeklin, T., Husman, T., Vepsäläinen, A., Vahteristo, M., Koivisto, J., Halla-Aho, J., Hyvärinen, A., Moschandreas, D., & Nevalainen, A. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.00169.x · Cited by 155
Self-citationKorpi, A., Pasanen, A. ‐., & Pasanen, P. O. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.8.2914-2919.1998 · Cited by 148
“The absence of visible signs of dampness and low airborne fungal levels are usually considered indications that there is little, if any, biocontamination in a building (21, 23).”
BackgroundSelf-citationLu, C., Deng, Q., Li, Y., Sundell, J., & Norbäck, D. (2016) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2016.04.033 · Cited by 156
Lee, T., Grinshpun, S. A., Martuzevičius, D., Adhikari, A., Crawford, C. M., Luo, J., & Reponen, T. A. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00396.x · Cited by 163
“These spores may be found in office or residential buildings that have excessive microbial growth because of moisture accumulation within the structure or inside the heating, ventilation and air conditioning (HVAC) system (Cole et al., 1994; Nevalainen et al., 1991).”
BackgroundSelf-citationLong-term sampling of airborne bacteria and fungi into a non-evaporating liquid
Lin, X., Reponen, T. A., Willeke, K., Grinshpun, S. A., Foarde, K. K., & Ensor, D. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00169-7 · Cited by 134
Self-citationCharacteristics of indoor and outdoor airborne fungi at suburban and urban homes in two seasons
Pei-Chih, W., Huey-Jen, S., & Chia-Yin, L. (2000) · The Science of The Total Environment · doi:10.1016/s0048-9697(00)00423-x · Cited by 134
Pasanen, A. ‐., Kalliokoski, P., Pasanen, P. O., Jantunen, M. J., & Nevalainen, A. I. (1991) · Environment International · doi:10.1016/0160-4120(91)90006-c · Cited by 132
Self-citationMould growth criteria and design avoidance approaches in wood-based materials – A systematic review
Gradeci, K., Labonnote, N., Time, B., & Köhler, J. (2017) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2017.05.204 · Cited by 128
Flood management: Prediction of microbial contamination in large-scale floods in urban environments
Taylor, J., Lai, K. M., Davies, M., Clifton, D. A., Ridley, I. A., & Biddulph, P. (2011) · Environment International · doi:10.1016/j.envint.2011.03.015 · Cited by 125
“Abnormally high levels of total bacteria have been found in mouldy indoor environments, whilst the presence of mesophilic actinomycetes is thought to be indicative of moisture problems (Nevalainen et al., 1991).”
BackgroundOccurrence and moisture requirements of microbial growth in building materials
Pasanen, A. ‐., Juutinen, T., Jantunen, M. J., & Kalliokoski, P. (1992) · International Biodeterioration & Biodegradation · doi:10.1016/0964-8305(92)90033-k · Cited by 125
Self-citationHuttunen, K., Hyvärinen, A., Nevalainen, A. I., Komulainen, H., & Hirvonen, M. (2002) · Environmental Health Perspectives · doi:10.1289/ehp.5478 · Cited by 124
“The gram-positive sporulating bacteria Streptomyces spp. have been frequently isolated from water-damaged buildings, but they are not part of the normal microbial flora of indoor air (Nevalainen et al. 1991).”
BackgroundInfluentialSelf-citationFilamentous microorganisms and their fragments in indoor air--a review.
Górny, R. L. (2004) · PubMed · Cited by 172
Aerodynamic characteristics and respiratory deposition of fungal fragments
Cho, S., Seo, S., Schmechel, D., Grinshpun, S. A., & Reponen, T. A. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.05.042 · Cited by 125
“In a Finnish study, the mean fungal spore level in the samples collected in moldy homes was even lower than that in the reference homes (Nevalainen et al., 1991).”
BackgroundSelf-citationAmbient bioaerosol indices for indoor air quality assessments of flood reclamation
Fabian, M. P., Miller, S. L., Reponen, T. A., & Hernandez, M. (2005) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.11.018 · Cited by 131
Self-citationNormal Range Criteria for Indoor Air Bacteria and Fungal Spores in a Subarctic Climate
Reponen, T. A., Nevalainen, A. I., Jantunen, M. J., Pellikka, M., & Kalliokoski, P. (1992) · Indoor Air · doi:10.1111/j.1600-0668.1992.03-21.x · Cited by 114
Self-citationTemporal and Spatial Variation of Fungal Concentrations in Indoor Air
Hyvärinen, A., Vahteristo, M., Meklin, T., Jantunen, M. J., Nevalainen, A. I., & Moschandreas, D. J. (2001) · Aerosol Science and Technology · doi:10.1080/02786820117763 · Cited by 141
“However, other studies assert that concentrations are not always higher in buildings with moisture problems compared to those in reference buildings (Strachan et al. 1990; Flannigan et al. 1991; Nevalainen et al. 1991).”
BackgroundSelf-citation(1999) · PubMed · Cited by 106
Fungal fragments in moldy houses: A field study in homes in New Orleans and Southern Ohio
Reponen, T. A., Seo, S., Grimsley, F., Lee, T., Crawford, C., & Grinshpun, S. A. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.06.027 · Cited by 109
“Furthermore, several field studies have shown that the concentrations of airborne fungal spores in mold problem buildings are not necessarily higher than in non-problem ones (Strachan et al., 1990; Nevalainen et al., 1991; Garrett et al., 1998; Chew et al., 2003).”
BackgroundSelf-citationPCR primers targeting the 16S rRNA gene for the specific detection of streptomycetes
Rintala, H., Nevalainen, A. I., Rönkä, E., & Suutari, M. H. (2001) · Molecular and Cellular Probes · doi:10.1006/mcpr.2001.0379 · Cited by 97
Self-citationCharacterizing Mold Problem Buildings - Concentrations And Flora Of Viable Fungi
Hyvarinen, A., Reponen, T., Husman, T., Ruuskanen, J., & Nevalainen, A. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00017.x · Cited by 95
Self-citationVOLATILE METABOLITES PRODUCED BY TWO FUNGAL SPECIES CULTIVATED ON BUILDING MATERIALS
Sunesson, A.-L., Nilsson, C. A., Andersson, B., & Blomquist, G. (1996) · The Annals of Occupational Hygiene · doi:10.1016/0003-4878(96)00002-6 · Cited by 94
Characteristics of Airborne Actinomycete Spores
Reponen, T. A., Gazenko, S. V., Grinshpun, S. A., Willeke, K., & Cole, E. C. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.10.3807-3812.1998 · Cited by 86
“Actinomycetes have been sampled from the air with impactors and have been analyzed by culturing (4, 7, 25).”
BackgroundMethodInfluentialSelf-citationAssessment of indoor air in Austrian apartments with and without visible mold growth
Haas, D., Habib, J., Galler, H., Buzina, W., Schlacher, R., Marth, E., & Reinthaler, F. F. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.07.062 · Cited by 89
Meklin, T., Reponen, T. A., Toivola, M., Koponen, V., Husman, T. M., Hyvärinen, A., & Nevalainen, A. I. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00769-0 · Cited by 86
Self-citationTäubel, M., Sulyok, M., Vishwanath, V., Bloom, E., Turunen, M., Järvi, K., Kauhanen, E., Krska, R., Hyvärinen, A., Larsson, L., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00721.x · Cited by 86
Self-citationIndoor microbiota in severely moisture damaged homes and the impact of interventions
Jayaprakash, B., Adams, R. I., Kirjavainen, P. V., Karvonen, A. M., Vepsäläinen, A., Valkonen, M., Järvi, K., Sulyok, M., Pekkanen, J., Hyvärinen, A., et al. (2017) · Microbiome · doi:10.1186/s40168-017-0356-5 · Cited by 76
“Based on cultivation studies, the presence of actinobacteria in samples of indoor air and building materials has been proposed to be indicative of moisture problems in Finnish buildings [19]; the reference here is”
Mould growth on building materials. Secondary metabolites, mycotoxins and biomarkers
Nielsen, K. F. (2001) · doi:10.13140/rg.2.1.4725.2007 · Cited by 78
pH effects on 10 Streptomyces spp. growth and sporulation depend on nutrients
Kontro, M. H., Lignell, U., Hirvonen, M.-R., & Nevalainen, A. I. (2005) · Letters in Applied Microbiology · doi:10.1111/j.1472-765x.2005.01727.x · Cited by 74
Self-citationHuttunen, K., Pelkonen, J., Nielsen, K. F., Nuutinen, U., Jussila, J., & Hirvonen, M. (2004) · Environmental Health Perspectives · doi:10.1289/ehp.6701 · Cited by 72
“Their occurrence is considered to be indicative of moisture damage; several studies have consistently found actinomycetes in moldy house samples (Hyvärinen et al. 2002; Nevalainen et al. 1991), and very active metabolites have been isolated from actinomycetes-rich samples (Andersson et al. 1998).”
ResultFungi and bacteria in mould-damaged and non-damaged office environments in a subarctic climate
Salonen, H., Lappalainen, S. K., Lindroos, O., Harju, R., & Reijula, K. E. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.04.043 · Cited by 70
Wang, J., Li, B., Yang, Q., Yu, W., Wang, H., Norbäck, D., & Sundell, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0072385 · Cited by 75
“Mold, yeasts, wood-rooting fungi, and bacteria can grow in damp buildings [55].”
BackgroundHussin, N. H. M., Sann, L. M., Shamsudin, M. N., & Hashim, Z. B. (2011) · Indoor and Built Environment · doi:10.1177/1420326x11414318 · Cited by 69
Jussila, J., Komulainen, H., Huttunen, K., Roponen, M., Hälinen, A., Hyvärinen, A., Kosma, V., Pelkonen, J., & Hirvonen, M.-R. (2001) · Toxicology and Applied Pharmacology · doi:10.1006/taap.2000.9116 · Cited by 76
Reponen, T. A., Hyvärinen, A., Ruuskanen, J., Raunemaa, T. M., & Nevalainen, A. I. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90227-5 · Cited by 72
Self-citationJussila, J., Komulainen, H., Kosma, V., Nevalainen, A. I., Pelkonen, J., & Hirvonen, M. (2002) · Inhalation Toxicology · doi:10.1080/08958370290084908 · Cited by 72
“Moisture-damaged buildings contain a different microbial flora from reference buildings (Samson et al., 1994), and increased spore concentrations have been frequently detected in the indoor air of moisture-damaged buildings (Nevalainen et al., 1991; Hyvärinen et al., 1993).”
BackgroundSelf-citationMurtoniemi, A. N. T. (2001) · Inhalation Toxicology · doi:10.1080/08958370150502467 · Cited by 73
Quantitative measurement of streptomycetes using real-time PCR
Rintala, H., & Nevalainen, A. I. (2006) · Journal of Environmental Monitoring · doi:10.1039/b602485h · Cited by 58
Self-citationSeasonal fungus prevalence inside and outside of domestic environments in the subtropical climate
Kuo, Y.-M., & Li, C.-S. (1994) · Atmospheric Environment · doi:10.1016/1352-2310(94)e0069-v · Cited by 57
Airborne mesophilic fungal spores in various residential environments
Pasanen, A.-L. (1992) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(92)90278-s · Cited by 55
Self-citationHirvonen, M., Nevalainen, A. I., Makkonen, N., Mönkkönen, J., & Savolainen, K. (1997) · Environmental Toxicology and Pharmacology · doi:10.1016/s1382-6689(96)00140-8 · Cited by 63
Self-citationHirvonen, M., Ruotsalainen, M., Savolainen, K., & Nevalainen, A. I. (1997) · Toxicology · doi:10.1016/s0300-483x(97)00141-8 · Cited by 63
Self-citationFrankel, M., Hansen, E. W., & Madsen, A. M. (2013) · Indoor Air · doi:10.1111/ina.12055 · Cited by 57
Claeson, A., Sandström, M., & Sunesson, A.-L. (2007) · Journal of Environmental Monitoring · doi:10.1039/b614766f · Cited by 48
Fungal spore transport through a building structure
Airaksinen, M., Kurnitski, J., Pasanen, P. O., & Seppänen, O. (2004) · Indoor Air · doi:10.1046/j.1600-0668.2003.00215.x · Cited by 47
“The health effects associated with moisture damage and microbial growth seem to be consistent in different climates and geographical regions (Ellringer et al. 2000, Hunter et al.1988, Li and Kuo 1994, Nevalainen et al. 1991).”
BackgroundAirborne Cladosporium and other fungi in damp versus reference residences
Pasanen, A. ‐., Niininen, M., Kalliokoski, P., Nevalainen, A. I., & Jantunen, M. J. (1992) · Atmospheric Environment Part B Urban Atmosphere · doi:10.1016/0957-1272(92)90044-s · Cited by 47
Self-citationKnudsen, S. M., Gunnarsen, L., & Madsen, A. M. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.06.017 · Cited by 46
Lair-Fulleringer, S., Seguin, D., Warin, S., Bezille, A., Desterque, C., Arné, P., Chermette, R., Bretagne, S., & Guillot, J. (2006) · Poultry Science · doi:10.1093/ps/85.11.1875 · Cited by 56
“, 1991); 100 to 2,300 cfu/m3 in “moldy” dwellings (Nevalainen et al., 1991); and 500 to 1,000 cfu/m3, the current standard (Miller et al.”
BackgroundInfluentialDetection of streptomycetes in house dust - comparison of culture and PCR methods
Rintala, H., Hyvärinen, A., Paulin, L. G., & Nevalainen, A. I. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2003.00219.x · Cited by 42
Self-citationRelease of Streptomyces albus propagules from contaminated surfaces
Górny, R. L., Mainelis, G., Grinshpun, S. A., Willeke, K., Dutkiewicz, J. K., & Reponen, T. A. (2003) · Environmental Research · doi:10.1016/s0013-9351(02)00006-3 · Cited by 50
Self-citationSick building syndrome symptoms among young parents in Chinese homes
Huo, X., Sun, Y., Hou, J., Wang, P., Kong, X., Zhang, Q., & Sundell, J. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106283 · Cited by 41
Characteristics of airborne microfungi in subtropical homes
Li, C.-S., & Kuo, Y.-M. (1994) · The Science of The Total Environment · doi:10.1016/0048-9697(94)90505-3 · Cited by 40
Sunesson, A.-L., NILSSON, C., CARLSON, R., Blomquist, G., & ANDERSSON, B. (1997) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(96)00046-4 · Cited by 40
“(Strachan et al, 1990; Flannigan et al., 1991; Nevalainen et al., 1991; Blomquist and Andersson, 1994).”
Claeson, A., Nordin, S., & Sunesson, A.-L. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00566.x · Cited by 42
Media for cultivation of indoor streptomycetes
Suutari, M. H., Lignell, U., Hyvärinen, A., & Nevalainen, A. I. (2002) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(02)00100-8 · Cited by 37
Self-citationEvaluation of priorities for repairing in moisture-damaged school buildings in Finland
Lappalainen, S. K., Kähkönen, E., Loikkanen, P., Palomäki, E., Lindroos, O., & Reijula, K. E. (2001) · Building and Environment · doi:10.1016/s0360-1323(00)00082-2 · Cited by 35
Diversity of streptomycetes in water-damaged building materials based on 16S rDNA sequences
Rintala, H., Nevalainen, A. I., & Suutari, M. H. (2002) · Letters in Applied Microbiology · doi:10.1046/j.1472-765x.2002.01120.x · Cited by 35
“In addition to various fungal species, mesophilic actinobacteria, including streptomycetes, are commonly isolated from air and building material samples of waterdamaged buildings (Nevalainen et al. 1991; Hyvärinen et al. 2002; Peltola et al. 2001).”
BackgroundSelf-citationMicrobiological indoor air quality in subtropical areas
Li, C.-S., & Kuo, Y.-M. (1993) · Environment International · doi:10.1016/0160-4120(93)90084-u · Cited by 34
Jussila, J., Pelkonen, J., Kosma, V., Mäki-Paakkanen, J., Komulainen, H., & Hirvonen, M.-R. (2003) · Clinical and Vaccine Immunology · doi:10.1128/cdli.10.1.30-37.2003 · Cited by 41
“Streptomyces californicus is a sporulating gram-positive bacterium that is used as a moisture indicator and that is frequently isolated from the indoor air of moisture-damaged buildings (27, 34).”
BackgroundWang, J., Li, B., Yang, Q., Wang, H., Norbäck, D., & Sundell, J. (2013) · Chinese Science Bulletin · doi:10.1007/s11434-013-5814-2 · Cited by 36
Masri, S., Miller, C. S., Palmer, R. F., & Ashford, N. A. (2021) · Environmental Sciences Europe · doi:10.1186/s12302-021-00504-z · Cited by 32
“, spores and VOCs) can build up to higher and more toxic concentrations than outdoors [50, 53].”
BackgroundMyers, N. T., Calderon, L., Pavilonis, B., Wang, Z., Xiong, Y., Allacci, M. S., Plotnik, D., Senick, J., Gong, J., Krogmann, U., et al. (2020) · Indoor Air · doi:10.1111/ina.12743 · Cited by 28
Analysis of Actinobacteria from mould-colonized water damaged building material
Schäfer, J., Jäckel, U., & Kämpfer, P. (2010) · Systematic and Applied Microbiology · doi:10.1016/j.syapm.2010.04.006 · Cited by 26
“In previous studies, Actinobacteria were reported in 18-70% of the investigated materials, dusts or bioaerosols of water damaged buildings, respectively [17 ,31 ,37 ,52].”
BackgroundEffects of Microbial Cocultivation on Inflammatory and Cytotoxic Potential of Spores
Murtoniemi, T., Penttinen, P., Nevalainen, A. I., & Hirvonen, M. (2005) · Inhalation Toxicology · doi:10.1080/08958370500189669 · Cited by 26
“…on the detection of the causative agents in moisture-damaged buildings has mainly been focused on molds (Verhoeff & Burge, 1997), there are some indications that bacteria may also contribute to the exposure and hence possibly to the health effects (Andersson et al., 1997; Nevalainen et al., 1991).”
BackgroundSelf-citationClaeson, A., & Sunesson, A.-L. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00343.x · Cited by 26
Bu, Z., Wang, L., Weschler, L. B., Li, B., Sundell, J., & Zhang, Y. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.023 · Cited by 26
Characterizing moisture damaged buildings : Environmental and biological monitoring
Hyvärinen, A. (2002) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 36
Sun, Y., Hou, J., Kong, X., Zhang, Q., Wang, P., Weschler, L. B., & Sundell, J. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.05.013 · Cited by 25
Effects of amoebae on the growth of microbes isolated from moisture-damaged buildings
Yli‐Pirilä, T., Kusnetsov, J. M., Hirvonen, M., Seuri, M., & Nevalainen, A. I. (2006) · Canadian Journal of Microbiology · doi:10.1139/w05-131 · Cited by 23
“Bacteria of the Gram-positive genus Streptomyces have been often isolated from water-damaged buildings, but they are usually not present in the indoor air samples taken in healthy buildings (Nevalainen et al. 1991).”
BackgroundSelf-citationCharacterisation of Streptomyces spp. isolated from water-damaged buildings
Suutari, M. H., Rönkä, E., Lignell, U., Rintala, H., & Nevalainen, A. I. (2002) · FEMS Microbiology Ecology · doi:10.1111/j.1574-6941.2002.tb00908.x · Cited by 23
“in water-damaged buildings [5,6], it was of interest to characterise a randomly selected, morphologically heterogeneous group of 11 strains di¡ering in biological activity [11^ 13] by determining fatty acid pro¢les, pigmentation and 16S rRNA gene sequences, widely used for microbial identi¢cation and evolutionary stud…”
BackgroundMethodSelf-citationRespiratory health of cigar factory workers.
Uitti, J. A., Nordman, H., Huuskonen, M. S., Roto, P., Husman, K., & Reiman, M. (1998) · Occupational and Environmental Medicine · doi:10.1136/oem.55.12.834 · Cited by 23
Viability of fungal and actinomycetal spores after microwave radiation of building materials.
Górny, R. L., Mainelis, G., Wlazło, A., Niesler, A., Lis, D. O., Marzec, S., Siwińska, E., Łudzeń-Izbińska, B., Harkawy, A., & Kasznia-Kocot, J. (2007) · PubMed · Cited by 30
Actinobacteria in indoor environments exposures and respiratory health effects
Rintala, H. (2011) · Frontiers in Bioscience-Scholar · doi:10.2741/225 · Cited by 21
Nasal Hyperreactivity among Teachers in a School with a Long History of Moisture Problems
Rudblad, S., Andersson, K., Stridh, G., Bodin, L., & Juto, J. (2001) · American Journal of Rhinology · doi:10.2500/105065801781543727 · Cited by 21
Hirvonen, M., Suutari, M. H., Ruotsalainen, M., Lignell, U., & Nevalainen, A. I. (2001) · Inhalation Toxicology · doi:10.1080/089583701459065 · Cited by 22
Self-citationPark, J., Cox‐Ganser, J. M., White, S., Laney, A. S., Caulfield, S., Turner, W. A., Sumner, A. D., & Kreiss, K. (2015) · Indoor Air · doi:10.1111/ina.12278 · Cited by 18
Kong, X., Sun, Y., Weschler, L. B., & Sundell, J. (2018) · Indoor and Built Environment · doi:10.1177/1420326x18756169 · Cited by 19
Nasir, Z. A., & Colbeck, I. (2012) · Water Air & Soil Pollution · doi:10.1007/s11270-012-1301-7 · Cited by 18
“A number of studies have been carried out to investigate the level of bioaerosols in indoor residential settings in different geographical regions (Dekoster and Thorne 1995; Gorny and Dutkiewicz 2002; Green et al. 2003; Haas et al. 2007; Hunter et al. 1996; Hyvarinen et al. 2001; Kalogerakis et al. 2005; Lee et al. 20…”
BackgroundCharacterization of Microorganisms in Indoor Environments
Lignell, U. (2008) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 19
Sunesson, A.-L. (1995) · DiVA at Umeå University (Umeå University) · Cited by 23
Seo, S., Han, Y., Kim, J., Choung, J. T., Kim, B. J., & Ahn, K. (2014) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2014.08.013 · Cited by 15
Analysis of Airborne Actinomycete Spores with Fluorogenic Substrates
Gazenko, S. V., Reponen, T. A., Grinshpun, S. A., & Willeke, K. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.11.4410-4415.1998 · Cited by 13
“Therefore, airborne actinomycete spores have traditionally been analyzed by impaction onto special nutrient media and subsequent colony enumeration (3, 16).”
BackgroundMethodSelf-citationChudzik, A., Jalkanen, K., Täubel, M., Szponar, B., & Paściak, M. (2024) · Microbiology Spectrum · doi:10.1128/spectrum.03596-23 · Cited by 12
“It is well known that Actinobacteria taxa of certain genera can grow together with fungi on wet building materials and, thus, indicate moisture problems (6, 7).”
BackgroundFungal aerosol composition in moldy basements
Afanou, A. K., Straumfors, A., & Eduard, W. (2019) · Indoor Air · doi:10.1111/ina.12567 · Cited by 14
The environmental microbiota and asthma
Kirjavainen, P. V., Hyytiäinen, H., & Täubel, M. (2019) · European Respiratory Society eBooks · doi:10.1183/2312508x.10016618 · Cited by 15
Tsao, Y.-C., & Hwang, Y. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.02.002 · Cited by 10
Lazaridis, M., & Colbeck, I. (2013) · Wiley eBooks · doi:10.1002/9781118682555.ch1 · Cited by 9
Teachers' health in moisture-damaged schools - a follow-up study
Patovirta, R.-L. (2005) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 12
Nasal symptoms among residents in moldy housing
Ruoppi, P. I., Husman, T. M., Reiman, M., Nuutinen, J., Hyvärinen, A., & Nevalainen, A. I. (2003) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.754 · Cited by 9
“In our northern climate, the most common causes of moisture damage are defects in the construction or maintenance of the dwellings (10, 11).”
BackgroundSelf-citationShao, Z., Wu, C., Shao, Q., Yang, J., & Xie, M. (2024) · Buildings · doi:10.3390/buildings14113388 · Cited by 9
Mold‐specific immunoglobulin G antibodies in a child population
Korppi, M. O., Laitinen, S., Taskinen, T., Reiman, M., Nevalainen, A. I., & Husman, T. M. (2003) · Pediatric Allergy and Immunology · doi:10.1034/j.1399-3038.2003.00059.x · Cited by 8
Self-citation
Metadata
- Authors
- Nevalainen, A., Pasanen, A.-L., Niininen, M., Reponen, T., Kalliokoski, P., & Jantunen, M. J.
- Affiliations
- University of Eastern Finland (FI)
- Venue
- Environment International
- Publisher
- Elsevier BV
- Published
- 1991-01
- Volume
- 17
- Issue
- 4
- Pages
- 299-302
- ISSN
- 0160-4120 (ISSN-L)
- OpenAlex
- W1993069782
- Semantic Scholar
- d4dbf46e2db0512da95d185f5a7efe4321cf50eb
- Cited by
- 126
- References
- 4
- Citations by year
- 2024: 2 · 2023: 3 · 2021: 2 · 2020: 1 · 2019: 4 · 2018: 3 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 2 · 2013: 7 · 2012: 3
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Environment International (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Life Sciences › Agricultural and Biological Sciences › Plant Science › Mycotoxins in Agriculture and Food
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor air quality, fungal spores, bioaerosols, thermophilic actinomycetes, indoor bacteria, poor ventilation, house dust mites
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.