Sealing cultured invertebrate neurons to embedded dish electrodes facilitates long-term stimulation and recording
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ashcroft, F. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90114-3 · Cited by 982
A miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., LOEB, G., BERWALDNETTER, Y., & OKUN, L. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580 · cited 1×
“…that has been placed in contact w~th a neuron to form a seal Planar arrays of electrodes embedded in the bottom of a culture dish have been used to record from a variety of cell culture preparations (Thomas et al., 1972; Pine, 1980; Gross et al., 1982; Israel et al., 1984; Novak and Wheeler, 1986).”
Tight-Seal Whole-Cell Recording
Marty, A., & Neher, E. (1983) · Single-Channel Recording · doi:10.1007/978-1-4615-7858-1_7 · Cited by 580
Recording action potentials from cultured neurons with extracellular microcircuit electrodes
Pine, J. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90042-4 · Cited by 543 · cited 4×
“Planar arrays of electrodes embedded in the bottom of a culture dish have been used to record from a variety of cell culture preparations (Thomas et al., 1972; Pine, 1980; Gross et al., 1982; Israel et al., 1984; Novak and Wheeler, 1986).”
BackgroundInfluentialSelf-citationGesteland, R. C., Howland, B., Lettvin, J. Y., & Pitts, W. H. (1959) · Proceedings of the IRE · doi:10.1109/jrproc.1959.287156 · Cited by 301
Schacher, S., & Proshansky, E. (1983) · The Journal of Neuroscience · doi:10.1523/jneurosci.03-12-02403.1983 · Cited by 279 · cited 3×
“Culturing techniques for Aplysta neurons were also similar to those reported elsewhere (Schacher and Proshansky, 1983; Lin and Levitan, 1987), with some minor differences: gangha were pinned to a Sylgard dish containing Aplysta-L15 media with 1 g/100 ml methyl cellulose, and neurons were removed by…”
BackgroundResultInfluentialSuppression of Neurite Elongation and Growth Cone Motility by Electrical Activity
Cohan, C. S., & Kater, S. B. (1986) · Science · doi:10.1126/science.3715470 · Cited by 276
Self-citationNeurite outgrowth in molluscan organ and cell cultures: the role of conditioning factor(s)
Wong, R., Hadley, R., Kater, S., & Hauser, G. (1981) · The Journal of Neuroscience · doi:10.1523/jneurosci.01-09-01008.1981 · Cited by 196 · cited 2×
“Following pioneering work on leech neurons (Ready and Nicholls, 1979), many types of identified invertebrate neurons have been grown in culture (Kaczmarek et al., 1979; Dagan and Levitan, 1981; Wong et al., 1981; Schacher and Proshansky , 1983).”
BackgroundMethodInfluentialOptical methods in cell physiology
Ronot, X., & Adolphe, M. (1987) · Biochimie · doi:10.1016/0300-9084(87)90035-6 · Cited by 154
Optical monitoring of membrane potential: methods of multisite optical measurement.
Cohen, L., & Lesher, S. (1986) · PubMed · Cited by 153
Gross, G. W., Williams, A. N., & Lucas, J. H. (1982) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(82)90046-2 · Cited by 148 · cited 6×
“…that has been placed in contact w~th a neuron to form a seal Planar arrays of electrodes embedded in the bottom of a culture dish have been used to record from a variety of cell culture preparations (Thomas et al., 1972; Pine, 1980; Gross et al., 1982; Israel et al., 1984; Novak and Wheeler, 1986).”
BackgroundMethodInfluentialThe morphology and coupling of Aplysia bag cells within the abdominal ganglion and in cell culture
Kaczmarek, L. K., Finbow, M. E., Revel, J. P., & Strumwasser, F. (1979) · Journal of Neurobiology · doi:10.1002/neu.480100604 · Cited by 143 · cited 1×
“Following pioneering work on leech neurons (Ready and Nicholls, 1979), many types of identified invertebrate neurons have been grown in culture (Kaczmarek et al., 1979; Dagan and Levitan, 1981; Wong et al., 1981; Schacher and Proshansky , 1983).”
BackgroundInfluentialEXTRACELLULAR POTENTIALS FROM SINGLE SPINAL MOTONEURONS
Freygang, W. H., & Frank, K. (1959) · The Journal of General Physiology · doi:10.1085/jgp.42.4.749 · Cited by 123
Stühmer, W., Roberts, W. M., & Almers, W. (1983) · Springer eBooks · doi:10.1007/978-1-4615-7858-1_8 · Cited by 103 · cited 1×
“We found this method to be electrophyslologically similar to that employed in loose-patchmg (Stuhmer et al., 1983), and to recording techniques used m vivo (Tauc, 1962; Neher and Lux, 1969).”
MethodSchacher, S. (1985) · Journal of Neuroscience · doi:10.1523/jneurosci.05-08-02028.1985 · Cited by 88
Recording from the Aplysia Abdominal Ganglion with a Planar Microelectrode Array
Novak, J. L., & Wheeler, B. C. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325891 · Cited by 79 · cited 2×
“…that has been placed in contact w~th a neuron to form a seal Planar arrays of electrodes embedded in the bottom of a culture dish have been used to record from a variety of cell culture preparations (Thomas et al., 1972; Pine, 1980; Gross et al., 1982; Israel et al., 1984; Novak and Wheeler, 1986).”
BackgroundIdentification of Active Membrane Areas in the Giant Neuron of Aplysia
Tauc, L. (1962) · The Journal of General Physiology · doi:10.1085/jgp.45.6.1099 · Cited by 78 · cited 1×
“We found this method to be electrophyslologically similar to that employed in loose-patchmg (Stuhmer et al., 1983), and to recording techniques used m vivo (Tauc, 1962; Neher and Lux, 1969).”
MethodA long-term in vitro silicon-based microelectrode-neuron connection
Regehr, W. G., Pine, J., & Rutledge, D. B. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8687 · Cited by 78 · cited 3×
“For stimulus pulses which are short compared to the nme constant of the cell (which is typically 5-20 ms). the internal voltage change is approximated by (Regehr et al., 1988a Since channel type and density in the patch are not known, the necessary stimulus current must be empirically determined.”
BackgroundMethodSelf-citationGiant Aplysia neuron R2 reliably forms strong chemical connections in vitro
Schacher, S., Rayport, S., & Ambron, R. (1985) · Journal of Neuroscience · doi:10.1523/jneurosci.05-11-02851.1985 · Cited by 50 · cited 1×
“Identified neurons used were those from the left upper quadrant of the abdominal ganglia (LUQs), the grant cell R2 (Schacher et al., 1985), abdominal neurons L10-L12, and the metacerebral cell (MCC).”
MethodCohan, C. S., Haydon, P. G., & Kater, S. B. (1985) · Journal of Neuroscience Research · doi:10.1002/jnr.490130119 · Cited by 50 · cited 1×
“For example, differences in recordings obtained from Hehsoma B5 and B19 neurons can be explained m terms of differences in the electrophyslology of these two types of neurons (Cohan et al., 1985).”
BackgroundSelf-citationParsons, T. D., Kleinfeld, D., Raccuia-Behling, F., & Salzberg, B. M. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82666-9 · Cited by 39 · cited 1×
“…voltage-sensitive dyes to opUcally measure the change in membrane potentml from large numbers of neurons simultaneously is promismg (Rayburn et al., 1984; Chien et al., 1987, Parsons et al., 1989), it ~s limited by the unavadability of a complementary means for stimulating and by dye phototox~city.”
BackgroundReal-time optical imaging of neuronal activity
Grinvald, A. (1984) · Trends in Neurosciences · doi:10.1016/s0166-2236(84)80125-3 · Cited by 27 · cited 1×
“…from the disadvantage that it is difficult to use array electrodes to detect the resulting action potentials; therefore, an independent means of stimulus verification such as voltage-sensitive dyes (Salzberg, 1982; Grinvald , 1984; Cohen and Lesher, 1986) or mtracellular recording is required.”
Background
Cited by
Welsh, D. K., Logothetis, D. E., Meister, M., & Reppert, S. M. (1995) · Neuron · doi:10.1016/0896-6273(95)90214-7 · Cited by 1,455
Synchronous bursts of action potentials in ganglion cells of the developing mammalian retina
Meister, M., Wong, R. O. L., Baylor, D. A., & Shatz, C. J. (1991) · Science · doi:10.1126/science.2035024 · Cited by 1,110
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Revealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“Regehr et al., 1989; Nisch et al., 1994; Oka et al., 1999; Litke et al., 2004; Segev et al., 2004; Greschner et al., 2014), but also MEAs with on-chip circuitry limited to the surrounding of the array (Greve et al., 2007) and arrays that include FETs (Offenhäusser et al., 1997) and source follower…”
Transient period of correlated bursting activity during development of the mammalian retina
Wong, R. O. L., Meister, M., & Shatz, C. J. (1993) · Neuron · doi:10.1016/0896-6273(93)90122-8 · Cited by 554
Metadata
- Authors
- Regehr, W. G., Pine, J., Cohan, C. S., Mischke, M. D., & Tank, D. W.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1989-11
- Volume
- 30
- Issue
- 2
- Pages
- 91-106
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2050753656
- Cited by
- 179
- References
- 22
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.