CoChat

One-incubation time-resolved fluoroimmunoassay based on monoclonal antibodies in detection of influenza A and B viruses directly in clinical

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

A new modified enzyme immunoassay screening method was developed for testing hybridoma cultures, so as to select antibodies useful for solid phase assays. Samples of hybridoma cultures were incubated for 1 h with purified nucleoprotein preparation in microtiter wells precoated with rabbit anti-influenza A or B immunoglobulin, followed by washing and addition of anti-mouse HRPO-conjugate. The monoclonal antibodies were then used in one-incubation time-resolved fluoroimmunoassay (TR-FIA) for detecting influenza viral proteins in nasopharyngeal aspirate specimens. The sample and europium (Eu)-labelled monoclonal detector antibody (100 microliter of each) were added simultaneously to microtiter wells precoated with anti-virus monoclonal antibody, and incubated for 1 h. After washing and addition of the enhancement solution the strips were shaken for 10 min before measurement of the fluorescence using a photon counting fluorometer. All of the monoclonal antibodies screened by our modified method and Eu-labelled worked as detector antibodies. Many of these monoclones also functioned as capture antibodies on solid phase. A total number of 309 (influenza A) and 104 (influenza B) nasopharyngeal aspirate specimens taken mainly from hospitalized children with acute respiratory disease were tested with the TR-FIA, using monoclonal antibodies produced by our modified screening method in comparison with monoclonal antibodies previously reported elsewhere (Walls et al., 1986). Results were similar, and superior to those obtained with routinely used indirect enzyme immunoassay based on polyclonal antibodies. The results of this study indicate that the one-incubation TR-FIA using monoclonal antibodies selected by the modified screening method is a highly sensitive and rapid method for detecting influenza A and influenza B virus in clinical specimens.

Overview

Integrity signals

Registry

Crossref · 10.1016/0166-0934(89)90086-4

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 14 references

Cited by

See all 35

Metadata

Authors
Nikkari, S., Halonen, P., Kharitonenkov, I., Kivivirta, M., Khristova, M., Waris, M., & Kendal, A.
Affiliations
  • University of Turku (FI)
  • D.I. Ivanovsky Institute of Virology Russian Academy of Medical Sciences (RU)
  • Centers for Disease Control and Prevention (US)
Corresponding author
Nikkari, S.
Venue
Journal of Virological Methods
Publisher
Elsevier BV
Published
1989-01
Volume
23
Issue
1
Pages
29-40
ISSN
0166-0934 (ISSN-L)
OpenAlex
W1975588181
Cited by
35
References
14
Citations by year
2026: 1 · 2016: 1 · 2015: 1 · 2012: 1
FWCI
4.07
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Journal of Virological Methods (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Academy of Finland
  • Medical Research Council
Topics
  • Health Sciences › Medicine › Epidemiology › Influenza Virus Research Studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Keywords
time-resolved fluoroimmunoassay, influenza A virus, influenza B, monoclonal antibodies, hybridoma screening, nasopharyngeal aspirates, virus detection, capture antibody, nucleocapsid protein
MeSH terms
Antibodies, Monoclonal, Antigens, Viral, Evaluation Studies as Topic, Fluorescent Antibody Technique, Humans, Immunoenzyme Techniques, Influenza, Human, Influenza A virus, Influenza B virus, Virology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: One-incubation time-resolved fluoroimmunoassay based on monoclonal antibodies in detection of influenza A and B viruses directly in clinical. https://app.cochat.ai/papers/10.1016/0166-0934(89)90086-4
The paper
Nikkari, S., Halonen, P., Kharitonenkov, I., Kivivirta, M., Khristova, M., Waris, M., & Kendal, A. (1989). One-incubation time-resolved fluoroimmunoassay based on monoclonal antibodies in detection of influenza A and B viruses directly in clinical. Journal of Virological Methods. https://doi.org/10.1016/0166-0934(89)90086-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.