Simultaneous time resolved SAXS and WAXS experiments using synchrotron radiation
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A small-angle X-ray scattering study of the annealing and gelatinization of starch
Cameron, R. E., & Donald, A. M. (1992) · Polymer · doi:10.1016/0032-3861(92)91147-t · Cited by 249
Design and performance of an imaging plate system for X-ray diffraction study
Amemiya, Y., Matsushita, T., Nakagawa, A., Satow, Y., Miyahara, J., & Chikawa, J.-I. (1988) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(88)90458-5 · Cited by 171
Synchrotron x-ray diffraction studies of the cornea, with implications for stromal hydration
Meek, K. M., Fullwood, N. J., Cooke, P. H., ELLIOTT, G. F., Maurice, D. M., Quantock, A. J., Wall, R. S., & Worthington, C. R. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82073-2 · Cited by 134
Multiwire X-ray detector systems at the daresbury srs
Lewis, R. A., Sumner, I., Berry, A., Bordas, J., Gabriel, A., Mant, G. R., Parker, B., Roberts, K. J., & Worgan, J. S. (1988) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(88)90094-0 · Cited by 37
Self-citation
Cited by
A SAXS/WAXS/GISAXS Beamline with Multilayer Monochromator
Hexemer, A., Bras, W., Glossinger, J., Schaible, E., Gann, E., Kirian, R., MacDowell, A., Church, M., Rude, B., & Padmore, H. (2010) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/247/1/012007 · Cited by 540
Self-citationSmall-Angle X-ray Scattering of Polymers
Chu, B., & Hsiao, B. S. (2001) · Chemical Reviews · doi:10.1021/cr9900376 · Cited by 455
Gelatinisation of starch: a combined SAXS/WAXS/DSC and SANS study
Jenkins, P. J., & Donald, A. M. (1998) · Carbohydrate Research · doi:10.1016/s0008-6215(98)00079-2 · Cited by 397
de Moor, P.-P. E. A., Beelen, T. P. M., & van Santen, R. A. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp982553q · Cited by 233
Transformations to and from the Gyroid Phase in a Diblock Copolymer
Vigild, M. E., Almdal, K., Mortensen, K., Hamley, I. W., Fairclough, J. P. A., & Ryan, A. J. (1998) · Macromolecules · doi:10.1021/ma9716746 · Cited by 232
Self-citation
Metadata
- Authors
- Bras, W., Derbyshire, G. E., Ryan, A. J., Mant, G. R., Felton, A., Lewis, R. A., Hall, C. J., & Greaves, G. N.
- Venue
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Publisher
- Elsevier BV
- Published
- 1993-03
- Volume
- 326
- Issue
- 3
- Pages
- 587-591
- ISSN
- 0168-9002 (ISSN-L)
- OpenAlex
- W2022604615
- Cited by
- 160
- References
- 4
- FWCI
- 8.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.