Improvement of the piecewise direct standardisation procedure for the transfer of NIR spectra for multivariate calibration
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computer Aided Design of Experiments
Kennard, R. W., & Stone, L. A. (1969) · Technometrics · doi:10.1080/00401706.1969.10490666 · Cited by 3,648
Multivariate instrument standardization
Wang, Y., Veltkamp, D. J., & Kowalski, B. R. (1991) · Analytical Chemistry · doi:10.1021/ac00023a016 · Cited by 610
New Standardization and Calibration Procedures for Nirs Analytical Systems
Shenk, J. S., & Westerhaus, M. O. (1991) · Crop Science · doi:10.2135/cropsci1991.0011183x003100060064x · Cited by 179
Calibration Transfer and Measurement Stability of Near-Infrared Spectrometers
Wang, Y., & Kowalski, B. R. (1992) · Applied Spectroscopy · doi:10.1366/0003702924124808 · Cited by 135
Bouveresse, E., Massart, D. L., & Dardenne, P. (1994) · Analytica Chimica Acta · doi:10.1016/0003-2670(94)00237-1 · Cited by 101
Self-citationCalibration Transfer Between near Infrared Reflectance Spectrophotometers1
Shenk, J. S., Westerhaus, M. O., & Templeton, W. C. (1985) · Crop Science · doi:10.2135/cropsci1985.0011183x002500010038x · Cited by 98
Modified Algorithm for Standardization of Near-Infrared Spectrometric Instruments
Bouveresse, E., Massart, D. L., & Dardenne, P. (1995) · Analytical Chemistry · doi:10.1021/ac00104a013 · Cited by 77
Self-citation
Cited by
Transfer of multivariate calibration models: a review
Feudale, R. N., Woody, N. A., Tan, H., Myles, A. J., Brown, S. D., & Ferré, J. (2002) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(02)00085-0 · Cited by 555
A Review of Calibration Transfer Practices and Instrument Differences in Spectroscopy
Workman, J. J. (2018) · Applied Spectroscopy · doi:10.1177/0003702817736064 · Cited by 223
“30 More detailed chemometric improvements to the basic technique of PDS for NIR spectrometric instruments is further described for multivariate calibration transfer in a 1996 paper.(31) One of the more common practical methods applied for field calibration transfers is PDS.”
MethodJi, W., Viscarra Rossel, R. A., & Shi, Z. (2015) · European Journal of Soil Science · doi:10.1111/ejss.12239 · Cited by 189
“The Kennard-Stone algorithm is the most widely used method for sample selection in spectral transfer research (Bouveresse & Massart, 1996b; Di Anibal et al., 2012).”
BackgroundMethodInfluentialChemometrics for Raman Spectroscopy Harmonization
Barton, B., Thomson, J., Lozano Diz, E., & Portela, R. (2022) · Applied Spectroscopy · doi:10.1177/00037028221094070 · Cited by 79
Metadata
- Authors
- Bouveresse, E., & Massart, D. L.
- Venue
- Chemometrics and Intelligent Laboratory Systems
- Publisher
- Elsevier BV
- Published
- 1996-03
- Volume
- 32
- Issue
- 2
- Pages
- 201-213
- ISSN
- 0169-7439 (ISSN-L)
- OpenAlex
- W2001735456
- Cited by
- 164
- References
- 7
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.