CoChat

The efficacy of hypnosis- and relaxation-induced analgesia on two dimensions of pain for cold pressor and electrical tooth pulp stimulation

Houle, Manon, McGrath, Patricia Anne, Moran, Greg, Garrett, Owen J. · 1988 · Pain
Cited by 43

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

This study evaluated the efficacy of hypnosis- and relaxation-induced suggestions for analgesia for reducing the strength and unpleasantness dimensions of pain evoked by noxious tooth pulp stimulation and by cold pressor stimulation. The Tellegen Absorption Questionnaire was used to assess hypnotic susceptibility for 28 subjects in order to match treatment groups according to sex and susceptibility scores. Tooth pulp stimulation consisted of a 1 sec train of 1 msec pulses at a frequency of 100 Hz, applied at 20 sec intervals to the central incisor. Six stimuli, selected between subject's pain and tolerance thresholds, were presented 3 times each in random order. Cold pressor stimulation consisted of forearm immersion in a circulating water bath maintained at 0-1 degrees C. Subjects made threshold determinations of pain and tolerance and used Visual Analogue Scales to rate the strength and the unpleasantness of both noxious stimuli before and after receiving either hypnosis- or relaxation-induced analgesia. There were no significant differences in pain reductions between hypnosis- and relaxation-induced interventions. However, the percent reduction in both strength and unpleasantness varied significantly as a function of the type of pain. Both hypnosis and relaxation significantly reduced the strength and the unpleasantness of tooth pulp stimulation, but only the unpleasantness dimension of cold pressor pain. The pain reductions were not correlated with subjects' hypnotic susceptibility levels. The results indicate that the extent and the quality of the analgesia produced by these cognitive-based therapies vary not only according to subjects' characteristics and the efficacy of the intervention, but also according to the nature of the noxious stimuli. Tooth pulp and cold pressor stimulation represent qualitatively different stimuli with respect to both the type of nerves activated and the mode of stimulus application. Discrete, randomly presented levels of noxious electrical stimulation to the teeth activate predominantly small fibers and produce brief pain sensations that vary unpredictably in intensity. In contrast, continuous cold stimulation to the forearm activates a variety of nociceptive and non-nociceptive fibers and produces progressive cold and pain sensations with a predictable increase in intensity from cold sensations to paresthesia and severe pain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0304-3959(88)90096-6

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 43

Metadata

Authors
Houle, M., McGrath, P. A., Moran, G., & Garrett, O. J.
Venue
Pain
Published
1988-05
Volume
33
Issue
2
Pages
241-251
ISSN
0304-3959 (ISSN-L)
OpenAlex
W1996384766
Cited by
43
References
6
FWCI
1.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The efficacy of hypnosis- and relaxation-induced analgesia on two dimensions of pain for cold pressor and electrical tooth pulp stimulation. https://app.cochat.ai/papers/10.1016/0304-3959(88)90096-6
The paper
Houle, M., McGrath, P. A., Moran, G., & Garrett, O. J. (1988). The efficacy of hypnosis- and relaxation-induced analgesia on two dimensions of pain for cold pressor and electrical tooth pulp stimulation. Pain. https://doi.org/10.1016/0304-3959(88)90096-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.