Effects of evaporator frosting and defrosting on the performance of air-to-water heat pumps

Tassou, S.A., Marquand, C.J.·1987·Applied Energy

Integrity signals

Registry

Crossref · 10.1016/0306-2619(87)90038-9

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • As frosting commences, heat extracted from the air by the evaporator is reduced, resulting in a decrease in refrigerant temperature, a decrease in refrigerant density at the compressor inlet, and reduction in both refrigerant flow rate and compressor power.

    “As frosting commences, the heat extracted from the air by evaporator is reduced, resulting in a decrease in refrigerant temperature, yielding a decrease in refrigerant density at the compressor inlet and leading to reduction in both refrigerant flow rate and compressor power.”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Tassou and Marquand (1987)

  • The mass of frost accumulated on the evaporator increases with air relative humidity.

    “The mass of frost accumulated on the evaporator increases with air relative humidity.”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Tassou and Marquand (1987)

  • The heating capacity and COP of the heat pump increased initially but later showed a gradual drop due to the insulating effect and drop in air flow.

    “The heating capacity and COP of the heat pump increased initially but later showed a gradual drop due to the insulating effect and drop in air flow.”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Tassou and Marquand (1987)

Cited by

Sorted by citations

Authors
Tassou, S. A., & Marquand, C. J.
Affiliations
University of West London (GB)
Venue
Applied Energy
Publisher
Elsevier BV
Published
1987
Volume
28
Issue
1
Pages
19-33
ISSN
0306-2619 (ISSN-L)
OpenAlex
W1978576078
Cited by
19
References
0
Citations by year
2024: 3 · 2022: 1 · 2021: 1 · 2019: 1 · 2017: 1 · 2013: 1 · 2012: 2
FWCI
1.36
Type
journal article
Language
en
Open access
closed
Locations
  • Applied Energy (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
air-to-water heat pump, thawing, frost formation, ambient temperature, humidity effects, pressure difference, evaporator coil

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review