Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 307

The DOI matches its Crossref record.

High resolution light and electron microscopic localization of tubulin with the IGS (immuno gold staining) method

DEMEY, J, MOEREMANS, M, GEUENS, G, NUYDENS, R, DEBRABANDER, M·1981·Cell Biology International Reports

Abstract

Abstract A new, simple procedure is described for the production of 5 nm colloidal gold/secondary antibody reagents. Utilizing them with antitubulin shows 1) that they can be used for high resolution ultrastructural localization studies and 2) that this can be done with retention of satisfactory preservation of cell structure. The same, simple procedure can be used to prepare 20 nm colloidal gold/antibody reagents. These can be used for the high resolution light microscopic visualization of microtubules in interphase and mitotic cells. Colloidal gold labelled serum or monoclonal antibodies can be used in a new, general purpose immunocytochemical technique: the IGS (immuno gold staining) method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0309-1651(81)90204-6

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 307

Metadata

Authors
DEMEY, J., MOEREMANS, M., GEUENS, G., NUYDENS, R., & DEBRABANDER, M.
Venue
Cell Biology International Reports
Publisher
Wiley
Published
1981-09
Volume
5
Issue
9
Pages
889-899
ISSN
0309-1651 (ISSN-L)
OpenAlex
W2072543637
Cited by
307
References
0
FWCI
10.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High resolution light and electron microscopic localization of tubulin with the IGS (immuno gold staining) method. https://app.cochat.ai/papers/10.1016/0309-1651(81)90204-6
The paper
DEMEY, J., MOEREMANS, M., GEUENS, G., NUYDENS, R., & DEBRABANDER, M. (1981). High resolution light and electron microscopic localization of tubulin with the IGS (immuno gold staining) method. Cell Biology International Reports. https://doi.org/10.1016/0309-1651(81)90204-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.