Pioneering new indoor temperature standards: the Pakistan project
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Outdoor temperatures and comfort indoors
Humphreys, M. (1978) · Batiment International, Building Research and Practice · doi:10.1080/09613217808550656 · Cited by 377
FIELD STUDIES OF THERMAL COMFORD COMPARED AND APPLIED.
Humphreys, M. (1976) · Cited by 303
Field studies of thermal comfort compared and applied
(1976) · Applied Ergonomics · doi:10.1016/0003-6870(76)90104-6 · Cited by 212
Airconditioning in Australia I—Human Thermal Factors
Auliciems, A., & de Dear, R. (1986) · Architectural Science Review · doi:10.1080/00038628.1988.9697267 · Cited by 99
Airconditioning in Australia III—Thermobile Controls
Auliciems, A. (1990) · Architectural Science Review · doi:10.1080/00038628.1990.9696669 · Cited by 18
Cited by
Thermal adaptation in the built environment: a literature review
Brager, G. S., & de Dear, R. J. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00053-4 · Cited by 1,483
Thermal comfort and building energy consumption implications—A review
Yang, L., Yan, H., & Lam, J. C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.10.062 · Cited by 1,448
A theoretical adaptive model of thermal comfort – Adaptive Predicted Mean Vote (aPMV)
Yao, R., Li, B., & Liu, J. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.02.014 · Cited by 709
Interactions with window openings by office occupants
Haldi, F., & Robinson, D. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.03.025 · Cited by 459
Thermal comfort for naturally ventilated houses in Indonesia
Feriadi, H., & Wong, N. H. (2004) · Energy and Buildings · doi:10.1016/j.enbuild.2004.01.011 · Cited by 367
Field studies on human thermal comfort — An overview
Mishra, A. K., & Ramgopal, M. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.02.015 · Cited by 336
Indraganti, M., & Rao, K. D. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2009.09.003 · Cited by 334
Damiati, S. A., Zaki, S. A., Rijal, H. B., & Wonorahardjo, S. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.09.024 · Cited by 265
Adaptive model of thermal comfort for offices in hot and humid climates of India
Indraganti, M., Ooka, R., Rijal, H. B., & Brager, G. S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.01.002 · Cited by 257
Climatic variations in comfortable temperatures: the Pakistan projects
Nicol, J. F., Raja, I. A., Allaudin, A., & Jamy, G. N. (1999) · Energy and Buildings · doi:10.1016/s0378-7788(99)00011-0 · Cited by 242
Yao, R., Zhang, S., Du, C., Schweiker, M., Hodder, S., Olesen, B. W., Toftum, J., Romana d'Ambrosio, F., Gebhardt, H., Zhou, S., et al. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109020 · Cited by 194
“Nicol and Roaf [55] 1996 Office NV Tcomf = 0.38 Tout +17.0 Occupants in Pakistan show large variations in desired indoor temperature.”
BackgroundMethodInfluentialClausen, P. A., Liu, Z., Kofoed-Sørensen, V., Little, J., & Wolkoff, P. (2012) · Environmental Science & Technology · doi:10.1021/es2035625 · Cited by 191
Kwong, Q. J., Adam, N. M., & Sahari, B. B. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2013.09.034 · Cited by 177
“[15] Pakistan Residential NV and OT = 30 ◦C”
BackgroundIndraganti, M., Ooka, R., & Rijal, H. B. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.12.008 · Cited by 162
Some evidence of a time-varying thermal perception
Vellei, M., O’Brien, W., Martinez, S., & Le Dréau, J. (2022) · Indoor and Built Environment · doi:10.1177/1420326x211034563 · Cited by 11
Metadata
- Authors
- Nicol, F., & Roaf, S.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 1996-03
- Volume
- 23
- Issue
- 3
- Pages
- 169-174
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2042174617
- Cited by
- 165
- References
- 5
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.