Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 298

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Improved thrombolysis with a modified dose regimen of recombinant tissue-type plasminogen activator

Open access
Neuhaus, Karl-Ludwig, Feuerer, Werner, Jeep-Tebbe, Susanne, Niederer, Walter, Vogt, Albrecht, Tebbe, Ulrich·1989·Journal of the American College of Cardiology

Abstract

To improve further the patency rate of infarct-related coronary arteries, the following accelerated dosage regimen of recombinant tissue-type plasminogen activator (rt-PA) was administered to 80 patients with acute myocardial infarction of less than or equal to 6 h duration: 15 mg intravenous bolus, 50 mg infusion over 30 min and 35 mg infusion over the following 60 min. After coronary angiography at 90 min coronary angioplasty was performed in 16 patients and additional thrombolysis in 3 patients. Six patients were not included in the final angiographic analysis, mostly because of borderline ST segment elevations, in order to avoid overestimation of the efficacy of this dose regimen. Four of these had a patent infarct artery; no early angiogram was performed on two. Sixty minutes after the start of infusion, 54 (74%) of 73 patients had a patent infarct-related artery (Thrombolysis in Myocardial Infarction [TIMI] grade 2 or 3) as did 67 (91%) of 74 patients at 90 min. At 24 h, 61 (92.4%) of 66 patients showed a patent infarct artery. Recurrent myocardial ischemia was noted in 12 patients, 7 (9.4%) of whom experienced reinfarction during the hospital stay. Minor local bleeding complications were observed in 14 patients (17.5%). There were four in-hospital cardiac deaths; one patient who underwent additional thrombolysis for recurrent ischemia died from bleeding complications. These results show that a rapid infusion of 100 mg of rt-PA over 90 min yields a high early patency rate of the infarct-related artery without an increase in reocclusion rate and adverse reactions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0735-1097(89)90399-9

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Metadata

Authors
Neuhaus, K.-L., Feuerer, W., Jeep-Tebbe, S., Niederer, W., Vogt, A., & Tebbe, U.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1989-11
Volume
14
Issue
6
Pages
1566-1569
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1994313737
Cited by
298
References
1
FWCI
22.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved thrombolysis with a modified dose regimen of recombinant tissue-type plasminogen activator. https://app.cochat.ai/papers/10.1016/0735-1097(89)90399-9
The paper
Neuhaus, K.-L., Feuerer, W., Jeep-Tebbe, S., Niederer, W., Vogt, A., & Tebbe, U. (1989). Improved thrombolysis with a modified dose regimen of recombinant tissue-type plasminogen activator. Journal of the American College of Cardiology. https://doi.org/10.1016/0735-1097(89)90399-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.