CoChat

Rate-modulated cardiac pacing based on transthoracic impedance measurements of minute ventilation: Correlation with exercise gas exchange

Open access
Kay, G.Neal, Bubien, Rosemary S., Epstein, Andrew E., Plumb, Vance J. · 1989 · Journal of the American College of Cardiology
Cited by 71

The DOI matches its Crossref record.

Abstract

The relation of pacing rate to physiologic variables of metabolic demand was examined in 10 consecutive patients with a minute ventilation-sensing, rate-modulating ventricular pacemaker implanted for complete heart block. All patients had paroxysmal (seven patients) or chronic (three patients) atrial fibrillation and were referred for catheter ablation of the atrioventricular junction. Treadmill exercise testing with measurement of expired gas exchange and respiratory flow was performed before ablation and 4 weeks after pacemaker implantation, with the pacemaker programmed to both the fixed-rate VVI and rate-modulating minute ventilation VVIR pacing modes in random sequence. The relation of pacing rate to oxygen consumption (VO2), expired carbon dioxide concentration (VCO2), respiratory quotient, tidal volume, respiratory rate and minute ventilation was determined during exercise in the rate-modulating minute ventilation pacing mode. Pacing rate was highly correlated with minute ventilation (r = 0.89), respiratory quotient (r = 0.89), VCO2 (r = 0.87), tidal volume (r = 0.87), VO2 (r = 0.84) and respiratory rate (r = 0.84). The mean exercise duration increased from 8.3 +/- 2.8 min in the fixed rate pacing mode to 10.2 +/- 3.4 min in the rate-modulating, minute ventilation mode (p = 0.0001). The maximal VO2 increased from 13.4 +/- 3.4 to 16.3 +/- 4.1 cc/kg per min (p = 0.0004). The maximal heart rate achieved in the minute ventilation pacing mode was 136 +/- 9.7 beats/min, similar to that observed in the patient's intrinsic cardiac rhythm before ablation (134.9 +/- 30.1 beats/min, p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0735-1097(89)90429-4

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 71

Metadata

Authors
Kay, G. N., Bubien, R. S., Epstein, A. E., & Plumb, V. J.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1989-11
Volume
14
Issue
5
Pages
1283-1289
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2037471792
Cited by
71
References
0
FWCI
3.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rate-modulated cardiac pacing based on transthoracic impedance measurements of minute ventilation: Correlation with exercise gas exchange. https://app.cochat.ai/papers/10.1016/0735-1097(89)90429-4
The paper
Kay, G. N., Bubien, R. S., Epstein, A. E., & Plumb, V. J. (1989). Rate-modulated cardiac pacing based on transthoracic impedance measurements of minute ventilation: Correlation with exercise gas exchange. Journal of the American College of Cardiology. https://doi.org/10.1016/0735-1097(89)90429-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.