CoChat

Electrophysiologic findings after Fontan repair of functional single ventricle

Open access
Kürer, Cheryl C., Tanner, Carol S., Vetter, Victoria L. · 1991 · Journal of the American College of Cardiology
Cited by 83

The DOI matches its Crossref record.

Abstract

Cardiac arrhythmias are well recognized sequelae of the Fontan operation for complex congenital anomalies. In this study the electrophysiologic effects of the Fontan procedure were evaluated in 30 patients who underwent cardiac catheterization with electrophysiologic study 1.9 +/- 1.3 years (mean +/- SD) after modified Fontan repair for functional single ventricle. Abnormalities of sinus node or ectopic pacemaker automaticity were detected in 50% (15 patients) by determination of a prolonged corrected sinus node or pacemaker recovery time. Total sinoatrial conduction time was prolonged in 50% of the patients with normal sinus rhythm. Sinus node or ectopic atrial pacemaker function was entirely normal in only 43% of patients. The predominant atrial rhythm was normal sinus in 70% and ectopic atrial or junctional in 30%. Abnormalities of atrial effective and functional refractory periods were noted in 43% of patients and were most pronounced at faster paced cycle lengths. Atrial endocardial catheter mapping revealed intraatrial conduction delays between adjacent sites in 76% of the patients tested and in eight of nine patients with inducible intraatrial reentry. Programmed atrial stimulation induced nonsustained supraventricular arrhythmias in 10% of the 30 patients and sustained arrhythmias in 27%. Intraatrial reentry was the most common inducible arrhythmia and was present in seven of the eight patients with sustained and two of the three patients with nonsustained atrial arrhythmias. Atrioventricular conduction abnormalities were noted in 10% (three patients). No patient had inducible ventricular arrhythmias with programmed ventricular stimulation. The electrophysiologic findings after Fontan repair include abnormal sinus node function, prolonged atrial refractoriness, delayed intraatrial conduction and inducible atrial arrhythmias.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0735-1097(91)90723-m

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 83

Metadata

Authors
Kürer, C. C., Tanner, C. S., & Vetter, V. L.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1991-01
Volume
17
Issue
1
Pages
174-181
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1989742767
Cited by
83
References
0
FWCI
2.09
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrophysiologic findings after Fontan repair of functional single ventricle. https://app.cochat.ai/papers/10.1016/0735-1097(91)90723-m
The paper
Kürer, C. C., Tanner, C. S., & Vetter, V. L. (1991). Electrophysiologic findings after Fontan repair of functional single ventricle. Journal of the American College of Cardiology. https://doi.org/10.1016/0735-1097(91)90723-m

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.