CoChat

Unique sensing errors in third-generation implantable cardioverter-defibrillators

Open access
Callans, David J., Hook, Bruce G., Kleiman, Robert B., Mitra, Raman L., Flores, Belinda T., Marchlinski, Francis E. · 1993 · Journal of the American College of Cardiology
Cited by 67

The DOI matches its Crossref record.

Abstract

OBJECTIVES: Third-generation cardioverter-defibrillators appear to be susceptible to unique sensing errors. This study was performed to determine the incidence and types of sensing errors in combination therapy implantable devices. BACKGROUND: One of the advantages offered by third-generation implantable cardioverter-defibrillators is the combination of bradycardia and antitachycardia pacing and cardioversion-defibrillation capabilities in a single device. The potential for unique sensing errors, those caused by the conflicts presented by combining bradycardia and tachycardia sensing and therapy algorithms in the same device, has not been previously addressed. METHODS: To determine the incidence of important sensing errors, 61 patients with a combination therapy device (Cadence [Ventritex] and PCD [Medtronic]) were studied for a 25-month period. In addition to surface electrocardiographic recordings during implantation and routine device testing, real-time and stored electrograms recorded from the rate-sensing leads (Cadence) and real-time marker channel recordings (PCD) were reviewed to diagnose sensing errors that resulted in symptoms, device inefficacy or delivery of inappropriate therapy. After recognition, specific reprogramming steps were performed in an attempt to avoid recurrent sensing errors. RESULTS: A total of 13 sensing errors were diagnosed in 12 patients (19.7%); the incidence was similar in both devices. Five distinct categories of sensing errors were identified. After device reprogramming, only one recurrent error occurred in 98 patient-months of follow-up. CONCLUSIONS: Important sensing errors occur in approximately 20% of patients with third-generation combination therapy cardioverter-defibrillators. Prompt diagnosis of sensing errors can lead to specific reprogramming steps to avoid recurrent errors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0735-1097(93)90428-4

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 67

Metadata

Authors
Callans, D. J., Hook, B. G., Kleiman, R. B., Mitra, R. L., Flores, B. T., & Marchlinski, F. E.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1993-10
Volume
22
Issue
4
Pages
1135-1140
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2034194778
Cited by
67
References
0
FWCI
7.16
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Unique sensing errors in third-generation implantable cardioverter-defibrillators. https://app.cochat.ai/papers/10.1016/0735-1097(93)90428-4
The paper
Callans, D. J., Hook, B. G., Kleiman, R. B., Mitra, R. L., Flores, B. T., & Marchlinski, F. E. (1993). Unique sensing errors in third-generation implantable cardioverter-defibrillators. Journal of the American College of Cardiology. https://doi.org/10.1016/0735-1097(93)90428-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.