CoChat

Comparison of thallium-201 single-photon emission computed tomography and electrocardiographic response during exercise in patients with normal rest electrocardiographic results

Open access
Nallamothu, Nasaraiah, Ghods, Massroor, Heo, Jaekyeong, Iskandrian, Abdulmassih S. · 1995 · Journal of the American College of Cardiology
Cited by 46

The DOI matches its Crossref record.

Abstract

OBJECTIVES: This study compared the diagnostic accuracy of exercise thallium-201 single-photon emission computed tomography (SPECT) with the exercise electrocardiographic (ECG) response in patients with normal baseline ECG results. BACKGROUND: Previous studies comparing exercise thallium imaging with exercise electrocardiography have included patients with abnormal rest ECG results that may have biased the results in favor of thallium imaging. METHODS: Of 321 patients with a pretest likelihood of coronary artery disease of 70 +/- 29% (mean +/- SD) who underwent exercise stress testing and coronary angiography, 68 had no coronary artery disease; 94 had one-vessel disease; 79 had two-vessel disease; and 80 had three-vessel or left main coronary artery disease. RESULTS: The diagnostic accuracy of SPECT was higher than that of the ECG response (79% vs. 49%, p < 0.0001). Patients with extensive (left main or three-vessel) coronary artery disease were older and had a lower work load, lower heart rate, greater ST segment depression and more extensive perfusion abnormalities than patients with no disease or one- or two-vessel disease. Multivariate discriminant analysis of exercise and thallium variables identified multivessel thallium abnormalities (F = 35), exercise heart rate (F = 18) and extent of ST segment depression (F = 6) as independent predictors of extensive disease. Of the 80 patients with left main or three-vessel disease, 37 (46%) had > or = 2-mm ST segment depression, 44 (55%) had multivessel SPECT abnormalities, and 61 (76%) had either > or = 2-mm ST depression or multivessel SPECT abnormalities (p = 0.0005 vs. the ECG response; p = 0.01 vs. SPECT). CONCLUSIONS: In patients with an intermediate to high pretest probability of coronary artery disease and normal baseline ECG results, SPECT is superior to the ECG response in detecting coronary disease. Further, SPECT provides incremental power in identifying patients with extensive (left main or three-vessel) coronary disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0735-1097(94)00471-2

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 46

Metadata

Authors
Nallamothu, N., Ghods, M., Heo, J., & Iskandrian, A. S.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1995-03
Volume
25
Issue
4
Pages
830-836
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2035917071
Cited by
46
References
0
FWCI
1.64
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of thallium-201 single-photon emission computed tomography and electrocardiographic response during exercise in patients with normal rest electrocardiographic results. https://app.cochat.ai/papers/10.1016/0735-1097(94)00471-2
The paper
Nallamothu, N., Ghods, M., Heo, J., & Iskandrian, A. S. (1995). Comparison of thallium-201 single-photon emission computed tomography and electrocardiographic response during exercise in patients with normal rest electrocardiographic results. Journal of the American College of Cardiology. https://doi.org/10.1016/0735-1097(94)00471-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.