CoChat

Rapid arterial hemostasis and decreased access site complications after cardiac catheterization and angioplasty: Results of a randomized trial of a novel hemostatic device

Kussmaul, William G., Buchbinder, Maurice, Whitlow, Patrick L., Aker, Umit T., Heuser, Richard R., King, Spencer B., Kent, Kenneth M., Leon, Martin B., Kolansky, Daniel M., Sandza, Joseph G. · 1995 · Journal of the American College of Cardiology
Cited by 202

The DOI matches its Crossref record.

Abstract

OBJECTIVES: This study was performed to test the safety and efficacy of a novel bioabsorbable hemostatic puncture closure device deployed through an arterial sheath. BACKGROUND: Cardiac catheterization procedures are associated with a risk of complications at the arterial access site. Increasing numbers of interventional procedures requiring large sheaths or intense anticoagulation underline the need for secure, rapid methods of obtaining hemostasis at the time of sheath removal. METHODS: We conducted a randomized, multicenter trial in 435 patients undergoing cardiac catheterization or angioplasty at eight participating centers. In 218 patients, hemostasis was achieved using the device (group I); 217 patients were assigned to the manual pressure control group (group II). RESULTS: There were no significant differences in baseline characteristics. Time to hemostasis was considerably shorter in group I (2.5 +/- 15.2 vs. 15.3 +/- 11.7 min [mean +/- SD], p < 0.0001). The deployment success rate for the device was 96%, and 76% of group I patients experienced immediate (within 1 min) hemostasis. Complication rates were lower in group I for bleeding, hematoma and occurrence of any complication. There was no difference in the small incidence of pseudoaneurysm formation. There was no change in either group in the ankle/brachial systolic blood pressure index. Ultrasound follow-up studies 60 days after device deployment revealed complete absorption of the device in all cases. Subgroup analysis revealed particular benefit in patients undergoing interventional procedures. The administration of heparin was associated with a significantly higher complication rate in the manual pressure control group, whereas heparin had no effect on hemostasis time or complication rates in the device group. CONCLUSIONS: This sheath-deployed, bioabsorbable device provides a safe and effective means of obtaining rapid arterial hemostasis after cardiac catheterization procedures. It appears to be particularly useful in those patients most at risk for access site complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0735-1097(95)00101-9

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kussmaul, W. G., Buchbinder, M., Whitlow, P. L., Aker, U. T., Heuser, R. R., King, S. B., Kent, K. M., Leon, M. B., Kolansky, D. M., & Sandza, J. G.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1995-06
Volume
25
Issue
7
Pages
1685-1692
ISSN
0735-1097
Cited by
202
References
0
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.