Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 269

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Use of P wave configuration during atrial tachycardia to predict site of origin

Open access
Tang, Chris W., Scheinman, Melvin M., Van Hare, George F., Epstein, Laurence M., Fitzpatrick, Adam P., Lee, Randall J., Lesh, Michael D.·1995·Journal of the American College of Cardiology

Abstract

OBJECTIVES This study sought to construct an algorithm to differentiate left atrial from right atrial tachycardia foci on the basis of surface electrocardiograms (ECGs). BACKGROUND Atrial tachycardia is an uncommon form of supraventricular tachycardia, often resistant to drug therapy. METHODS A total of 31 consecutive patients with atrial tachycardia due to either abnormal automaticity or triggered rhythm underwent detailed atrial endocardial mapping and successful radiofrequency catheter ablation of a single atrial focus. P wave configuration was analyzed from 12-lead ECGs during tachycardia during either spontaneous or pharmacologically induced atrioventricular block. P waves inscribed above the isoelectric line (TP interval) were classified as positive, below as negative, above and below (or conversely, below and above) as biphasic and flat P waves as isoelectric (0). In 17 patients the tachycardia was located in the right atrium: crista terminalis (n = 4); right atrial appendage (n = 4); lateral wall (n = 4); posteroinferior right atrium (n = 3); tricuspid annulus (n = 1); and near the coronary sinus (n = 1). In 14 patients, atrial tachycardia was located in the left atrium: at the entrance of the right (n = 6) or left (n = 4) superior pulmonary veins; left inferior pulmonary vein (n = 1); inferior left atrium (n = 1); base of left atrial appendage (n = 1); and high lateral left atrium (n = 1). RESULTS There were no differences in P wave vectors between sites at the right atrial lateral wall versus the right atrial appendage or between sites at the entrance of right versus left superior pulmonary veins. However, analysis of P wave configuration showed that leads aVL and V1 were most helpful in distinguishing right atrial from left atrial foci. The sensitivity and specificity of using a positive or biphasic P wave in lead aVL to predict a right atrial focus was 88% and 79%, respectively. The sensitivity and specificity of a positive P wave in lead V1 in predicting a left atrial focus was 93% and 88%, respectively. CONCLUSIONS 1) Analyses of surface P wave configuration proved to be reasonably good in differentiating right atrial from left atrial tachycardia foci. 2) Leads II, III and aVF were helpful in providing clues for differentiating superior from inferior foci.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0735-1097(95)00307-x

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 269

Metadata

Authors
Tang, C. W., Scheinman, M. M., Van Hare, G. F., Epstein, L. M., Fitzpatrick, A. P., Lee, R. J., & Lesh, M. D.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1995-11
Volume
26
Issue
5
Pages
1315-1324
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1970859841
Cited by
269
References
15
FWCI
4.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of P wave configuration during atrial tachycardia to predict site of origin. https://app.cochat.ai/papers/10.1016/0735-1097(95)00307-x
The paper
Tang, C. W., Scheinman, M. M., Van Hare, G. F., Epstein, L. M., Fitzpatrick, A. P., Lee, R. J., & Lesh, M. D. (1995). Use of P wave configuration during atrial tachycardia to predict site of origin. Journal of the American College of Cardiology. https://doi.org/10.1016/0735-1097(95)00307-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.