Use of hemodynamic parameters in the diagnosis of mesenteric insufficiency
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
To evaluate the hemodynamic characteristics of the normal mesenteric circulation, five parameters of the velocity waveforms were measured in 15 normal subjects in the celiac and superior mesenteric arteries (SMA) in the pre- and postprandial periods. It was noted that changes in celiac artery flow after eating was minimal, indicating that this vessel's major supply function is not to the gut. SMA parameters showing the most significant and consistent changes after a meal were the diastolic reverse flow and diastolic forward flow (DFF). Four patients referred with symptoms of intestinal angina underwent scanning and subsequent angiography of their mesenteric circulation. All four exhibited loss of reverse flow in the SMA. The change in DFF in the SMA was statistically significant (p = 0.01). Change in peak systolic velocity in the celiac artery was marginally significant (p = 0.05). Angiography revealed that three patients had greater than 90% stenosis of both vessels. The fourth patient had a 90% celiac artery and 65% SMA stenosis. The technique described offers the first noninvasive means of identifying mesenteric insufficiency. It is an effective screening method for a disease entity difficult to verify without selective arteriography. The use of velocity waveform parameters giving good discrimination between normal subjects and those with stenoses of the visceral arteries should reduce both the incidence of missed diagnosis and unnecessary angiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BUCHARDT HANSEN, H. J., ENGELL, H. C., RING-LARSEN, H., & RANEK, L. (1977) · Annals of Surgery · doi:10.1097/00000658-197708000-00016 · Cited by 55
Cited by
Mesenteric duplex scanning: A blinded prospective study
Moneta, G. L., Lee, R. W., Yeager, R. A., Taylor, L. M., & Porter, J. M. (1993) · Journal of Vascular Surgery · doi:10.1016/0741-5214(93)90011-a · Cited by 283
Duplex ultrasound measurement of postprandial intestinal blood flow: Effect of meal composition
Moneta, G. L., Taylor, D. C., Helton, W. S., Mulholland, M. W., & Strandness, D. E. (1988) · Gastroenterology · doi:10.1016/0016-5085(88)90364-2 · Cited by 277
Self-citationDuplex ultrasound criteria for diagnosis of splanchnic artery stenosis or occlusion
Moneta, G. L., Yeager, R. A., Dalman, R., Antonovic, R., Hall, L. D., & Porter, J. M. (1991) · Journal of Vascular Surgery · doi:10.1016/0741-5214(91)90245-p · Cited by 235
Meaney, J. F. M., Prince, M. R., Nostrant, T. T., & Stanley, J. C. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070126 · Cited by 193
Revascularization of the superior mesenteric artery alone for treatment of intestinal ischemia
Foley, M. I., Moneta, G. L., Abou-Zamzam, A. M., Edwards, J. M., Taylor, L. M., Yeager, R. A., & Porter, J. M. (2000) · Journal of Vascular Surgery · doi:10.1067/mva.2000.107314 · Cited by 181
Metadata
- Authors
- Nicholls, S. C., Kohler, T. R., Martin, R. L., & Strandness, D. E.
- Venue
- Journal of Vascular Surgery
- Publisher
- Elsevier BV
- Published
- 1986-03
- Volume
- 3
- Issue
- 3
- Pages
- 507-510
- ISSN
- 0741-5214 (ISSN-L)
- OpenAlex
- W2075519169
- Cited by
- 93
- References
- 1
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.