Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 247

The DOI matches its Crossref record.

Definitive landmarks for reproducible tibial tunnel placement in anterior cruciate ligament reconstruction

Morgan, Craig D., Kalman, Victor R., Grawl, Daniel M.·1995·Arthroscopy: The Journal of Arthroscopic & Related Surgery

Abstract

The purpose of this prospective study was to define constant anatomic intraarticular and extraarticular landmarks that can be used as definitive reference points to reproducibly create a tibial tunnel for anterior cruciate ligament (ACL) reconstruction that (1) results in an impingement-free graft in full extension without an intercondylar roofplasty; (2) positions the tibial tunnel's intraarticular orafice sagittally central in the original ACL insertion without visually guessing; (3) positions the tibial tunnel such that the sagittal tunnel-plateau angle is parallel with the sagittal intercondylar roof-plateau angle in full extension to minimize shear seen by the graft at the tibial tunnel inlet, and by doing so; (4) maximizes tunnel length to avoid patellar tendon graft-tunnel length mismatch allowing for endosteal interference screw fixation on both sides of the joint. Anatomic dissections in 50 knees showed the ACL sagittal central insertion point on the intercondylar floor averages 7 mm (range 7 to 8 mm) sagittally anterior to the anterior margin of the posterior cruciate ligament (PCL) with the knee flexed 90 degrees such that the PCL may be used as a reliable reference landmark for locating the ACL sagittal central insertion. This constant relationship was found to be independent of knee size. Extraarticularly, beginning the tibial tunnel sagittally 1 cm above the superior (sartorial) border of the pes anserinus insertion and coronally 1.5 cm posteromedial from the medial margin of the tibial tubercle along the superior surface of the pes, directed toward the sagittal central ACL insertion, led to a sagittal tunnel-plateau angle that averaged 68 degrees (range 64 degrees to 72 degrees) with a corresponding tunnel length that averaged 58 mm (range 50 to 65 mm) in 23 knees. This data correlated well with data obtained clinically in a series of 50 consecutive ACL reconstructions using intraarticular PCL and extraarticular pes anserine-medial tibial tubercle referenced tibial tunnels in which postoperative full extension lateral radiographs confirmed a sagittal tunnel-plateau angle parallel or near parallel with the intercondylar roof-plateau angle in all cases averaging 68 degrees +/- 3.8 degrees. Tibial tunnel length averaged 60 mm (range 52 to 66 mm) and in no case was there a patellar tendon autograft-tunnel length mismatch.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0749-8063(95)90003-9

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 247

Metadata

Authors
Morgan, C. D., Kalman, V. R., & Grawl, D. M.
Venue
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher
Elsevier BV
Published
1995-06
Volume
11
Issue
3
Pages
275-288
ISSN
0749-8063 (ISSN-L)
OpenAlex
W1969504431
Cited by
247
References
0
FWCI
7.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Definitive landmarks for reproducible tibial tunnel placement in anterior cruciate ligament reconstruction. https://app.cochat.ai/papers/10.1016/0749-8063(95)90003-9
The paper
Morgan, C. D., Kalman, V. R., & Grawl, D. M. (1995). Definitive landmarks for reproducible tibial tunnel placement in anterior cruciate ligament reconstruction. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1016/0749-8063(95)90003-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.