Excitation modes for fourier transform-ion cyclotron resonance mass spectrometry
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Various geometric configurations for the excitation of coherent ion motion in Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR/MS) are analyzed (in some cases for the first time) with unified notation. The instantaneous power absorption, F v, in which v is ion velocity and F the force produced by the applied excitation electric field (harmonic, single frequency, on-resonance, in-phase), is time averaged and then set equal to the time rate of change of ion total (cyclotron + magnetron + trapping) energy, to yield a differential equation that is readily solved for the (time-dependent) amplitude of each of the various ion motions. The standard FT-ICR excitation (namely, radial dipolar) is reviewed. The effects of quadrature and radial quadrupolar excitation on ion radial (cyclotron and magnetron) motions are also reviewed. Frictional damping is shown to decrease the ion cyclotron orbital radius and trapping amplitude but increase the magnetron radius. Feedback excitation (i.e., excitation at the simultaneously detected ion cyclotron orbital frequency of the same ion packet) is introduced and analyzed as a means for exciting ions whose cyclotron frequency changes during excitation (as for relativistically shifted low-mass ions). In contrast to conventional radial dipolar excitation, axial dipolar excitation of the trapping motion leads to a mass-dependent ion motional amplitude. Parametric (i.e., axial quadrupolar) excitation is shown to produce an exponential increase in the ion motional amplitudes (hyperbolic sine and hyperbolic cosine amplitude for cyclotron and magnetron radii, respectively). More detailed consideration of parametric excitation leads to an optimal ion initial radial position in parametric-mode FT-ICRjMS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
Currents to Conductors Induced by a Moving Point Charge
Shockley, W. (1938) · Journal of Applied Physics · doi:10.1063/1.1710367 · Cited by 1,300
Mode coupling in a Penning trap:π pulses and a classical avoided crossing
Cornell, E. A., Weisskoff, R. M., Boyce, K. R., & Pritchard, D. E. (1990) · Physical Review A · doi:10.1103/physreva.41.312 · Cited by 181
Wineland, D., & Dehmelt, H. (1975) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(75)87031-8 · Cited by 90
Single particle motion in a Penning trap: description in the classical canonical formalism
Kretzschmar, M. (1992) · Physica Scripta · doi:10.1088/0031-8949/46/6/011 · Cited by 65
Particle motion in a Penning trap
Kretzschmar, M. (1991) · European Journal of Physics · doi:10.1088/0143-0807/12/5/010 · Cited by 61
Cited by
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Self-citationMilestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
Self-citationFourier transform ion cyclotron resonance detection: principles and experimental configurations
Marshall, A. G., & Hendrickson, C. L. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00588-7 · Cited by 196
Self-citationThe Ramsey method in high-precision mass spectrometry with Penning traps: Experimental results
George, S., Blaum, K., Herfurth, F., Herlert, A., Kretzschmar, M., Nagy, S., Schwarz, S., Schweikhard, L., & Yazidjian, C. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.04.003 · Cited by 174
Self-citationThe Ramsey method in high-precision mass spectrometry with Penning traps: Theoretical foundations
Kretzschmar, M. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.04.002 · Cited by 165
Metadata
- Authors
- Schweikhard, L., & Marshall, A. G.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1993-06-01
- Volume
- 4
- Issue
- 6
- Pages
- 433-452
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2058641986
- Cited by
- 100
- References
- 6
- FWCI
- 9.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Excitation modes for fourier transform-ion cyclotron resonance mass spectrometry. https://app.cochat.ai/papers/10.1016/1044-0305(93)80001-f
- The paper
- Schweikhard, L., & Marshall, A. G. (1993). Excitation modes for fourier transform-ion cyclotron resonance mass spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/1044-0305(93)80001-f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.