Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

The effects of loading changes on intraoperative doppler assessment of mitral regurgitation

Konstadt, Steven N., Louie, Eric K., Shore-Lesserson, Linda, Black, Susan, Scanlon, Patrick · 1994 · Journal of Cardiothoracic and Vascular Anesthesia

Abstract

Anesthetic agents may significantly alter the patient's blood pressure, and thus affect the intraoperative assessment of mitral regurgitation. This study examined the impact of an increase in afterload on a variety of parameters thought to reflect the severity of mitral regurgitation, and related them to changes in hemodynamic parameters. Twenty-four patients with mitral regurgitation undergoing cardiac surgery were studied. Following the induction of anesthesia, color-flow mapping of the entire left atrium was performed, and pulmonary vein flow was then measured. Phenylephrine was administered to increase the patients' blood pressures to their preoperative values, and the assessment was repeated. Regurgitant jet area increased 56% (482 +/- 405 v 750 +/- 440 mm2 P < 0.001), and there were significant reductions in systolic pulmonary venous velocity (0.33 +/- 0.17 v 0.18 +/- .31 m/s P < .01) with increases in diastolic flow (0.43 +/- 12 v 0.58 +/- 0.18 m/s P < .001). These changes in pulmonary venous flow were not related to the changes in the driving force across the incompetent mitral valve. Also, an additional six patients developed systolic flow reversal after phenylephrine administration. Intraoperative hemodynamic variations can significantly alter the apparent severity of mitral regurgitation, and this factor must be considered during decision making.

Overview

Integrity signals

Registry

Crossref · 10.1016/1053-0770(94)90006-x

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Metadata

Authors
Konstadt, S. N., Louie, E. K., Shore-Lesserson, L., Black, S., & Scanlon, P.
Affiliations
Loyola University Medical Center (US)
Corresponding author
Konstadt, Steven N.
Venue
Journal of Cardiothoracic and Vascular Anesthesia
Publisher
Elsevier BV
Published
1994-02
Volume
8
Issue
1
Pages
19-23
ISSN
1053-0770 (ISSN-L)
OpenAlex
W2087201631
Cited by
54
References
15
Citations by year
2026: 2 · 2024: 1 · 2023: 1 · 2020: 2 · 2018: 1 · 2017: 2 · 2015: 3 · 2014: 2 · 2012: 3
FWCI
3.47
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Journal of Cardiothoracic and Vascular Anesthesia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
Keywords
mitral regurgitation, afterload, phenylephrine, pulmonary venous flow, regurgitant jet area, mitral valve surgery, color flow mapping
MeSH terms
Adult, Aged, Blood Flow Velocity, Blood Pressure, Cardiac Output, Diastole, Female, Heart Atria, Humans, Male, Middle Aged, Mitral Valve Insufficiency, Phenylephrine, Pulmonary Artery, Pulmonary Veins, Pulmonary Wedge Pressure, Regional Blood Flow, Systole, Echocardiography, Doppler, Monitoring, Intraoperative, Ventricular Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effects of loading changes on intraoperative doppler assessment of mitral regurgitation. https://app.cochat.ai/papers/10.1016/1053-0770(94)90006-x
The paper
Konstadt, S. N., Louie, E. K., Shore-Lesserson, L., Black, S., & Scanlon, P. (1994). The effects of loading changes on intraoperative doppler assessment of mitral regurgitation. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1016/1053-0770(94)90006-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.