Heart rate variability spectra based on non-equidistant sampling: the spectrum of counts and the instantaneous heart rate spectrum
The DOI matches its Crossref record.
Abstract
This paper compares two methods to estimate heart rate variability spectra, i.e., the spectrum of counts and the instantaneous heart rate spectrum. Contrary to Fourier techniques based on equidistant sampling of the interbeat intervals, the spectrum of counts and the instantaneous heart rate spectrum are based on non-equidistant sampling: the values are determined at R-wave moments. A consequence of the non-equidistant occurrence of the R-peaks in a heart rate signal is the appearance of the sidebands of the harmonic components of the mean heart rate in the spectra. These sidebands contaminate the signal components in the spectrum. The sideband distortion in the instantaneous heart rate spectrum was found to be smaller than in the spectrum of counts. Simulations using the IPFM-model were made to quantify this difference. On the basis of these simulations, sideband distortion appeared to be dependent on the mean heart rate, the modulation depth and the modulation frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962
Dieleman, G. C., Huizink, A. C., Tulen, J. H. M., Utens, E. M. W. J., Creemers, H. E., van der Ende, J., & Verhulst, F. C. (2015) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2014.09.002 · Cited by 141
“…discrete Fourier transform, ased on non-equidistant sampling of the R-wave incidences CARSPAN program, Groningen, The Netherlands (Mulder t al., 1988); van Steenis et al., 1994), to yield power specra of the rhythmic oscillations over a frequency range of .02—0.50 Hz, with a resolution of 0.01 Hz.”
BackgroundInfluentialSelf-citationMaternal Psychopathology Influences Infant Heart Rate Variability: Generation R Study
Dierckx, B., Tulen, J. H. M., van den Berg, M. P., Tharner, A., Jaddoe, V. W., Moll, H. A., Hofman, A., Verhulst, F. C., & Tiemeier, H. (2009) · Psychosomatic Medicine · doi:10.1097/psy.0b013e318198a82c · Cited by 48
“formation, based on nonequidistant sampling of the R-wave indices (36).”
BackgroundSelf-citation
Metadata
- Authors
- van Steenis, H. G., Tulen, J. H. M., & Mulder, L. J. M.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 1994-09-01
- Volume
- 16
- Issue
- 5
- Pages
- 355-362
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2110784703
- Cited by
- 44
- References
- 0
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heart rate variability spectra based on non-equidistant sampling: the spectrum of counts and the instantaneous heart rate spectrum. https://app.cochat.ai/papers/10.1016/1350-4533(90)90001-o
- The paper
- van Steenis, H. G., Tulen, J. H. M., & Mulder, L. J. M. (1994). Heart rate variability spectra based on non-equidistant sampling: the spectrum of counts and the instantaneous heart rate spectrum. Medical Engineering & Physics. https://doi.org/10.1016/1350-4533(90)90001-o
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.