BASIC PULSE SEQUENCES
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments
Carr, H. Y., & Purcell, E. M. (1954) · Physical Review · doi:10.1103/physrev.94.630 · Cited by 6,466
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Application of Fourier Transform Spectroscopy to Magnetic Resonance
Ernst, R. R., & Anderson, W. A. (1966) · Review of Scientific Instruments · doi:10.1063/1.1719961 · Cited by 1,683
Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)
Mugler, J. P., & Brookeman, J. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150117 · Cited by 1,265
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Steady-State Free Precession in Nuclear Magnetic Resonance
Carr, H. Y. (1958) · Physical Review · doi:10.1103/physrev.112.1693 · Cited by 579
MR imaging: clinical use of the inversion recovery sequence.
Bydder, G. M., & YOUNG, I. R. (1985) · PubMed · Cited by 477
MR Imaging: Clinical Use of the Inversion Recovery Sequence
Bydder, G. M., & Young, I. R. (1985) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198507010-00002 · Cited by 426
Rapid NMR imaging of dynamic processes using the FLASII technique
Frahm, J., Haase, A., & Matthaei, D. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030217 · Cited by 381
Cited by
Glaser, S. J., Boscain, U., Calarco, T., Koch, C. P., Köckenberger, W., Kosloff, R., Kuprov, I., Luy, B., Schirmer, S., Schulte-Herbrüggen, T., et al. (2015) · The European Physical Journal D · doi:10.1140/epjd/e2015-60464-1 · Cited by 774
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014) · RadioGraphics · doi:10.1148/rg.341135130 · Cited by 370
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
Multiparametric imaging with heterogeneous radiofrequency fields
Cloos, M. A., Knoll, F., Zhao, T., Block, K. T., Bruno, M., Wiggins, G. C., & Sodickson, D. K. (2016) · Nature Communications · doi:10.1038/ncomms12445 · Cited by 184
In-vitro tomography and non-destructive imaging at depth of pharmaceutical solid dosage forms
ZEITLER, J., & GLADDEN, L. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.08.012 · Cited by 177
Rieger, B., Akçakaya, M., Pariente, J. C., Llufriu, S., Martinez-Heras, E., Weingärtner, S., & Schad, L. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-24920-z · Cited by 39
Effect of inaccurate b-values from imaging gradients on intravoxel incoherent motion
Rashid, I. A., Szczepankiewicz, F., Gunnlaugsson, A., Olsson, L. E., & Brynolfsson, P. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30579 · Cited by 8
“33 For example, the slice-selective rewinder can be merged with the crusher prewinder, as opposed to having two gradient blocks performing these tasks as close as possible to the imaging gradients in question.”
Influential
Metadata
- Authors
- BERNSTEIN, M. A., KING, K. F., & ZHOU, X. J.
- Venue
- Handbook of MRI Pulse Sequences
- Publisher
- Elsevier
- Published
- 2004
- Pages
- 579-647
- OpenAlex
- W2909768175
- Cited by
- 209
- References
- 29
- FWCI
- 1.43
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.