Disinfection, Sterilization, and Control of Hospital Waste
Open accessThe DOI matches its Crossref record; 248 of the 248 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–248 of 248
Jackson, F., & Ball, M. D. (1997) · Archives of Family Medicine · doi:10.1001/archfami.6.6.578 · Cited by 34
Cronmiller, J. R., Nelson, D. K., Jackson, D. K., & Kim, C. H. (1999) · Helicobacter · doi:10.1046/j.1523-5378.1999.99275.x · Cited by 33
Farina, A., Fievet, M. ‐., Plassart, F., Menet, M., & Thuillier, A. (1999) · Journal of Hospital Infection · doi:10.1016/s0195-6701(99)90425-5 · Cited by 31 · cited 1×
“3 mg/L).(120) Similarly, keratopathy and corneal damage were caused by ophthalmic instruments that were inadequately rinsed after soaking in 2% glutaraldehyde.”
BackgroundSterility testing validation of sterilization processes and sporicide testing
Oxborrow, G. S., & Berube, R. (1991) · Cited by 31
Payan, C., Cottin, J., Lemarié, C., & Ramont, C. (2001) · Journal of Hospital Infection · doi:10.1053/jhin.2001.0945 · Cited by 30
Surface Analysis of Clinically Used Expanded PTFE Endoscopic Tubing Treated By the STERIS PROCESS
Tucker, R. C., Lestini, B. J., & Marchant, R. E. (1996) · ASAIO Journal · doi:10.1097/00002480-199642040-00014 · Cited by 30
Doan, H. M., Keith, L., & Shennan, A. T. (1979) · PEDIATRICS · doi:10.1542/peds.64.3.324 · Cited by 29
Esophageal Stenosis Produced by Ingestion of Bleach: Report of Two cases
FRENCH, R. J., Tabb, H. G., & Rutledge, L. J. (1970) · Southern Medical Journal · doi:10.1097/00007611-197010000-00010 · Cited by 28 · cited 1×
“15%) may produce ocular irritation or oropharyngeal, esophageal, and gastric burns.(69,80,81) Other disadvantages of hypochlorites include corrosiveness to metals in high concentrations (>500 ppm), inactivation by organic matter, discoloring or “bleaching” of fabrics, release of toxic chlorine gas when mixed with ammo…”
BackgroundSattar, S. A., Adegbunrin, O., & Ramírez, J. A. (2002) · American Journal of Infection Control · doi:10.1067/mic.2002.126428 · Cited by 28
Rutala, W. A., & Weber, D. J. (2023) · American Journal of Infection Control · doi:10.1016/j.ajic.2023.03.013 · Cited by 27
Self-citationJakobsson, S. W., Rajs, J., Jonsson, J. A., & Persson, H. (1991) · American Journal of Forensic Medicine & Pathology · doi:10.1097/00000433-199112000-00009 · Cited by 27 · cited 1×
“, bactericidal, virucidal, fungicidal, mycobactericidal, sporicidal), do not leave toxic residues, are unaffected by water hardness, are inexpensive and fast acting,(74,76) remove dried or fixed organisms and biofilms from surfaces,(77) and have a low incidence of serious toxicity.(78,79) Sodium hypochlorite at the co…”
BackgroundLiquid Chemical Sterilization Using Peracetic Acid: An Alternative Approach to Endoscope Processing
Wallace, C. G., Agee, P. M., & Demicco, D. D. (1995) · ASAIO Journal · doi:10.1097/00002480-199506000-00005 · Cited by 27
An outbreak of surgical wound infections due to Clostridium perfringens.
EICKHOFF, T. C. (1962) · PubMed · Cited by 27
Disinfectant Testing Using a Modified Use-Dilution Method: Collaborative Study
Cole, E. C., Rutala, W. A., & Samsa, G. P. (1988) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/71.6.1187 · Cited by 26
Self-citationMannion, P. T. (1995) · Journal of Hospital Infection · doi:10.1016/0195-6701(95)90281-3 · Cited by 26
A Note on the Fallacy of Using Alcohol for the Sterilization of Surgical Instruments
Nye, R. N., & MALLORY, T. B. (1923) · New England Journal of Medicine · doi:10.1056/nejm192310181891603 · Cited by 26 · cited 1×
“Fatal postoperative wound infections with Clostridium have occurred when alcohols were used to sterilize surgical instruments contaminated with bacterial spores.(73) Alcohols have been used effectively to disinfect oral and rectal thermometers, computers,(60) hospital pagers, scissors, cardiopulmonary resuscitation (C…”
BackgroundUse of a fluorescent chemical as a quality indicator for a hospital cleaning program.
Blue, J., O’Neill, C., Speziale, P., Revill, J., Ramage, L., & Ballantyne, L. (2008) · PubMed · Cited by 25
Dialyser Reprocessing with Renalin®
Fleming, S. J., Foreman, K., Shanley, K., Mihrshahi, R., & Siskind, V. (2008) · American Journal of Nephrology · doi:10.1159/000168268 · Cited by 25 · cited 1×
“The combination of peracetic acid and hydrogen peroxide has been used for disinfecting hemodialyzers.(172) The percentage of dialysis centers using a peracetic acid with hydrogen peroxide–based disinfectant for reprocessing dialyzers increased from 5% in 1983 to 72% in 1997.”
BackgroundRoeßler, M., Wilke, A., GRISS, P., & Kienapfel, H. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(2000)53:2<131::aid-jbm1>3.0.co;2-i · Cited by 24
Patient Injury From Flash-Sterilized Instruments
Rutala, W. A., Weber, D. J., & Chappell, K. J. (1999) · Infection Control and Hospital Epidemiology · doi:10.1086/503136 · Cited by 24
Self-citationNot all super-oxidized waters are the same
Sampson, M., & Muir, A. V. G. (2002) · Journal of Hospital Infection · doi:10.1053/jhin.2002.1304 · Cited by 24 · cited 2×
“The free available chlorine concentrations of different superoxidized solutions reported in the literature range from 7 to 180 ppm.(84) Data have shown that freshly generated superoxidized water is rapidly effective (<2 minutes) in achieving a 5-log10 reduction of pathogenic microorganisms (i.”
BackgroundComparison of the Activities and Stabilities of Alkaline Glutaraldehyde Sterilizing Solutions
Pepper, R. E. (1980) · Infection Control · doi:10.1017/s0195941700052607 · Cited by 24 · cited 1×
“, now use life of 28 to 30 days) while generally maintaining excellent microbicidal activity.(74,75,102,103) However, it should be recognized that antimicrobial activity is dependent not only on age but also on use conditions such as dilution and organic stress.”
BackgroundEfficacy of a Washer-Pasteurizer for Disinfection of Respiratory-Care Equipment
Rutala, W. A., Weber, D. J., Gergen, M. F., & Gratta, A. R. (2000) · Infection Control and Hospital Epidemiology · doi:10.1086/501767 · Cited by 23
Self-citationGurevich, I., Tafuro, P., Ristuccia, P. A., Herrmann, J., Young, A., & Cunha, B. A. (1983) · Journal of Hospital Infection · doi:10.1016/0195-6701(83)90051-8 · Cited by 23
Bacterial Killing Ability of 10% Ethylene Oxide Plus 90% Hydrochlorofluorocarbon Sterilizing Gas
Alfa, M. J., DeGagné, P., & Olson, N. L. (1997) · Infection Control and Hospital Epidemiology · doi:10.2307/30141492 · Cited by 21
IMPORTANCE OF LUMEN FLOW IN LIQUID CHEMICAL STERILIZATION
Alfa, M. J. (1999) · American Journal of Infection Control · doi:10.1016/s0196-6553(99)70062-3 · Cited by 21
THE 1999 LINDBERG AWARD 3% Hydrogen Peroxide for the Gram–Positive Disinfection of Fabrics
Neely, A. N., & Maley, M. P. (1999) · Journal of Burn Care & Rehabilitation · doi:10.1097/00004630-199920060-00008 · Cited by 20 · cited 1×
“Hydrogen peroxide was effective in spotdisinfecting fabrics in patients’ rooms.(129) Corneal damage from a hydrogen peroxide–soaked tonometer tip that was not properly rinsed has been reported.”
BackgroundCurrent Instrument Reprocessing Practices: Results of a National Survey
Muscarella, L. F. (2001) · Gastroenterology Nursing · doi:10.1097/00001610-200109000-00007 · Cited by 20
Glutaraldehyde: A Potential Health Risk to Nurses
NEWMAN, M. A., & Kachuba, J. B. (1992) · Gastroenterology Nursing · doi:10.1097/00001610-199206000-00005 · Cited by 19 · cited 1×
“05 ppm, it would be prudent to take corrective action and repeat monitoring.(122)”
BackgroundWescodyne: lack of activity against poliovirus in the presence of organic matter.
Am, W., Drulak, M., Poffenroth, L., Barnes, C., Kay, C., & Lebtag, I. (1978) · PubMed · Cited by 19
Risk of iatrogenic transmission of Helicobacter pylori by gastroscopes
Shimada, T., Terano, A., Ota, S., Takikawa, H., & Sumino, S. (1996) · The Lancet · doi:10.1016/s0140-6736(96)90997-6 · Cited by 18
When the Biological Indicator Is Positive: Investigating Autoclave Failures
Bryce, E. A., Roberts, F. J., Clements, B., & MacLean, S. (1997) · Infection Control and Hospital Epidemiology · doi:10.2307/30141494 · Cited by 18
Disinfection of an infrared coagulation device used to treat hemorrhoids
Rutala, W. A., Gergen, M. F., & Weber, D. J. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.04.330 · Cited by 16
Self-citationVirucidal activity of ortho-phthalaldehyde solutions against hepatitis B and C viruses
Roberts, C. G., Chan-Myers, H., & Favero, M. S. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.08.005 · Cited by 16
Duc, D. L., Ribiollet, A., Dode, X., Ducel, G., Marchetti, B., & Calop, J. (2001) · Journal of Hospital Infection · doi:10.1053/jhin.2001.0900 · Cited by 16
Gurevich, I., Oadri, S. M. H., & Cunha, B. A. (1993) · American Journal of Infection Control · doi:10.1016/0196-6553(93)90207-k · Cited by 15
Disinfection and flash sterilization in the operating room.
Rutala, W. A. (1991) · PubMed · Cited by 14
Self-citationHolton, J., & Shetty, N. (1997) · Journal of Hospital Infection · doi:10.1016/s0195-6701(97)90214-0 · Cited by 13 · cited 1×
“Although this product is rapidly effective against a broad range of microorganisms,(168,169) it tarnishes the metal of endoscopes and is unstable, resulting in only a 24-hour use life.(169)”
BackgroundGordon, M. D., Ezzell, R. J., Bruckner, N. I., & Ascenzi, J. M. (1994) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/bf01584102 · Cited by 13
Studies on the disinfection of VRE-contaminated surfaces.
Rutala, W. A., Weber, D. J., & Gergen, M. F. (2000) · PubMed · Cited by 13
Self-citationEvaluation of Two Hot Water Washer Disinfectors for Medical Instruments
Jetté, L. P., & Lambert, N. G. (1988) · Infection Control and Hospital Epidemiology · doi:10.2307/30146443 · Cited by 12
Evaluation of sterilization of dental handpieces by heating in synthetic compressor lubricant.
Se, S., & Hill, D. E. (1999) · PubMed · Cited by 12
An outbreak of rotavirus gastroenteritis on a pediatric unit
Chapin, M., Yatabe, J. A. H., & Cherry, J. D. (1983) · American Journal of Infection Control · doi:10.1016/0196-6553(83)90119-0 · Cited by 10
Glutaraldehyde test kits: evaluation for accuracy and range.
Overton, D., Burgess, J. O., Beck, B., & Matis, B. A. (1989) · PubMed · Cited by 10
The Effect of Steam Sterilization on Plaster Casting Material
GILBERT, J. A., & Phillips, H. O. (1984) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198411000-00041 · Cited by 10 · cited 1×
“Failure of ETO also has been observed when dental handpieces were contaminated and combustion of lubricants associated with dental handpieces,(203) reduction in ability to transmit light associated with laryngoscopes,(204) and increased hardening time (fivefold to sixfold) with plaster cast.(205) The basic principle o…”
Background'Road Signs' approach to hand hygience
Ndawula, E., & Cutter, M. (2001) · Journal of Hospital Infection · doi:10.1053/jhin.2001.1005 · Cited by 6
Rutala, W. A., & Mayhall, C. G. (1992) · Infection Control and Hospital Epidemiology · doi:10.2307/30146966
Self-citation
Cited by
Challenges and strategies for effective plastic waste management during and post COVID-19 pandemic
Vanapalli, K. R., Sharma, H. B., Ranjan, V. P., Samal, B., Bhattacharya, J., Dubey, B. K., & Goel, S. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.141514 · Cited by 731
Disinfection and Sterilization in Health Care Facilities
Rutala, W. A., & Weber, D. J. (2016) · Infectious Disease Clinics of North America · doi:10.1016/j.idc.2016.04.002 · Cited by 222
Self-citationLineback, C. B., Nkemngong, C. A., Wu, S. T., Li, X., Teska, P. J., & Oliver, H. F. (2018) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-018-0447-5 · Cited by 188
Disinfection, sterilization, and antisepsis: An overview
Rutala, W. A., & Weber, D. J. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2015.10.038 · Cited by 174
Self-citationDisinfection, sterilization, and antisepsis: An overview
Rutala, W. A., & Weber, D. J. (2019) · American Journal of Infection Control · doi:10.1016/j.ajic.2019.01.018 · Cited by 136
Self-citation
Metadata
- Authors
- Rutala, W. A., & Weber, D. J.
- Venue
- Mandell, Douglas, and Bennett's Principles and Practice of Infectious Diseases
- Publisher
- Elsevier
- Published
- 2015
- Pages
- 3294-3309.e4
- OpenAlex
- W2482687639
- Cited by
- 182
- References
- 248
- FWCI
- 13.51
- Type
- book chapter
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.