Serial-section electron microscopy using automated tape-collecting ultramicrotome (ATUM)
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The Automated Tape-Collecting Ultramicrotome (ATUM) is tape-reeling device that is placed in a water-filled diamond knife boat to collect serial sections as they are cut by a conventional ultramicrotome. The ATUM can collect thousands of sections of many different shapes and sizes, which are subsequently imaged by a scanning electron microscope. This method has been used for large-scale connectomics projects of mouse brain, and is well suited for other smaller-scale studies of tissues, cells, and organisms. Here, we describe basic procedures for preparing a block for ATUM sectioning, handling of the ATUM, tape preparation, post-treatment of sections, and considerations for mapping, imaging, and aligning the serial sections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saturated Reconstruction of a Volume of Neocortex
Kasthuri, N., Hayworth, K. J., Berger, D. R., Schalek, R. L., Conchello, J. A., Knowles-Barley, S., Lee, D., Vázquez-Reina, A., Kaynig, V., Jones, T. R., et al. (2015) · Cell · doi:10.1016/j.cell.2015.06.054 · Cited by 1,044
Self-citationHigh-precision automated reconstruction of neurons with flood-filling networks
Januszewski, M., Kornfeld, J., Li, P. H., Pope, A., Blakely, T., Lindsey, L., Maitin-Shepard, J., Tyka, M., Denk, W., & Jain, V. (2018) · Nature Methods · doi:10.1038/s41592-018-0049-4 · Cited by 380
High-contrast en bloc staining of neuronal tissue for field emission scanning electron microscopy
Tapia, J. C., Kasthuri, N., Hayworth, K. J., Schalek, R., Lichtman, J. W., Smith, S. J., & Buchanan, J. (2012) · Nature Protocols · doi:10.1038/nprot.2011.439 · Cited by 296
Self-citationHayworth, K. J., Morgan, J. L., Schalek, R., Berger, D. R., Hildebrand, D. G. C., & Lichtman, J. W. (2014) · Frontiers in Neural Circuits · doi:10.3389/fncir.2014.00068 · Cited by 282
Self-citation
Cited by
Connectomes across development reveal principles of brain maturation
Witvliet, D., Mulcahy, B., Mitchell, J. K., Meirovitch, Y., Berger, D. R., Wu, Y., Liu, Y., Koh, W. X., Parvathala, R., Holmyard, D., et al. (2021) · Nature · doi:10.1038/s41586-021-03778-8 · Cited by 393
Self-citationHuang, S. Y., Witzel, T., Keil, B., Scholz, A., Davids, M., Dietz, P., Rummert, E., Ramb, R., Kirsch, J. E., Yendiki, A., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118530 · Cited by 181
“The cured block containing full-thickness cerebral cortex and subcortical white matter was trimmed to a 2 × 3 mm2 rectangle and a depth of 200 μm and imaged 8 × 8 × 30 nm3 using serial-section scanning EM (Sigma, Carl Zeiss) with a custom-built automated tape-collecting ultramicrotome (Baena et al., 2019).”
Self-citationEvolution of the ribbon-like organization of the Golgi apparatus in animal cells
(2024) · doi:10.1016/j.celrep.2024.113791 · Cited by 18
Evolution of the ribbon-like organization of the Golgi apparatus in animal cells
Benvenuto, G., Leone, S., Astoricchio, E., Bormke, S., Jasek, S., D’Aniello, E., Kittelmann, M., McDonald, K., Hartenstein, V., Baena, V., et al. (2023) · doi:10.1101/2023.02.16.528797 · Cited by 1
Self-citation
Metadata
- Authors
- Baena, V., Schalek, R. L., Lichtman, J. W., & Terasaki, M.
- Venue
- Methods in Cell Biology
- Publisher
- Elsevier
- Published
- 2019
- Volume
- 152
- Pages
- 41-67
- ISSN
- 0091-679X (ISSN-L)
- OpenAlex
- W2959132662
- Cited by
- 82
- References
- 4
- FWCI
- 10.59
- Type
- book chapter
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.