The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
A glucose biosensor based on chitosan–glucose oxidase–gold nanoparticles biocomposite formed by one-step electrodeposition
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hayakawa, K., Yoshimura, T., & Esumi, K. (2003) · Langmuir · doi:10.1021/la034339l · Cited by 438
Polymer-Stabilized Gold Nanoparticles and Their Incorporation into Polymer Matrices
Corbierre, M. K., Cameron, N. S., Sutton, M., Mochrie, S. G. J., Lurio, L. B., Rühm, A., & Lennox, R. B. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0166287 · Cited by 390
Use of Gold Nanoparticles To Enhance Capillary Electrophoresis
Neiman, B., Grushka, E., & Lev, O. E. (2001) · Analytical Chemistry · doi:10.1021/ac0104375 · Cited by 155
Spatially Selective Deposition of a Reactive Polysaccharide Layer onto a Patterned Template
Wu, L., Yi, H., Li, S., Rubloff, G. W., Bentley, W. E., Reza Ghodssi, A., & Payne, G. F. (2003) · Langmuir · doi:10.1021/la026518t · Cited by 120
Bharathi, S., & Nogami, M. (2001) · The Analyst · doi:10.1039/b105318n · Cited by 111
Glucose microbiosensor based on alumina sol–gel matrix/electropolymerized composite membrane
Chen, X., Hu, Y., & Wilson, G. S. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00093-3 · Cited by 96
Yang, X., Hua, L., Gong, H., & Tan, S. N. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)01507-6 · Cited by 84
Studies on the formation of bioconjugates of Endoglucanase with colloidal gold
Gole, A. M., Vyas, S., Phadtare, S., Lachke, A. H., & Sastry, M. (2002) · Colloids and Surfaces B Biointerfaces · doi:10.1016/s0927-7765(01)00301-0 · Cited by 61
Free-Standing Nanogold Membranes as Scaffolds for Enzyme Immobilization
Phadtare, S., Vathipadiekal, V., Wadgaonkar, P. P., Rao, M., & Sastry, M. (2004) · Langmuir · doi:10.1021/la035870j · Cited by 37
Bioelectrocatalytical glucose oxidation with phenoxazine modified glucose oxidase
Krikštopaitis, K., Kulys, J. J., & Tetianec, L. (2004) · Electrochemistry Communications · doi:10.1016/j.elecom.2004.01.011 · Cited by 35
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Gold nanoparticle-based electrochemical biosensors
Pingarrón, J. M., Yáñez-Sedeño, P., & González-Cortés, A. (2008) · Electrochimica Acta · doi:10.1016/j.electacta.2008.03.005 · Cited by 965
Functionalized Gold Nanoparticles and Their Biomedical Applications
Tiwari, P. M., Vig, K., Dennis, V. A., & Singh, S. R. (2011) · Nanomaterials · doi:10.3390/nano1010031 · Cited by 840
Yi, H., Wu, L.-Q., Bentley, W. E., Ghodssi, R., Rubloff, G. W., Culver, J. N., & Payne, G. F. (2005) · Biomacromolecules · doi:10.1021/bm050410l · Cited by 759
Synthesis and electrochemical applications of gold nanoparticles
Guo, S., & Wang, E. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.054 · Cited by 693
Metadata
- Authors
- Luo, X.-L., Xu, J.-J., Du, Y., & Chen, H.-Y.
- Venue
- Analytical Biochemistry
- Publisher
- Elsevier BV
- Published
- 2004-11
- Volume
- 334
- Issue
- 2
- Pages
- 284-289
- ISSN
- 0003-2697 (ISSN-L)
- OpenAlex
- W2014261370
- Cited by
- 397
- References
- 10
- FWCI
- 13.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.