Recorded scan times can limit the accuracy of sedimentation coefficients in analytical ultracentrifugation
Open accessThe DOI matches its Crossref record.
Abstract
We report systematic and large inaccuracies in the recorded elapsed time in data files from the analytical ultracentrifuge, leading to overestimates of the sedimentation coefficients of up to 10%. This far exceeds previously considered factors contributing to the uncertainty in this parameter, and has significant ramifications for derived parameters, such as hydrodynamic shape and molar mass estimates. The source of this error is at present unknown, but we found it to be quantitatively consistent across different instruments, increasing with rotor speed. Furthermore, its occurrence appears to correlate with the use of the latest data acquisition software from the manufacturer, in use in some of our laboratories for nearly two years. Many of the recently published sedimentation coefficients may need to be re-examined. The problem can be easily recognized by comparing the file time-stamps provided by the operating system with the elapsed scan times recorded within the data files. We therefore implemented a routine in SEDFIT that can automatically examine the data files, alert the user to significant discrepancies, and correct the scan times accordingly. This eliminates errors in the recorded scan times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Structural basis of recognition of farnesylated and methylated KRAS4b by PDEδ
Dharmaiah, S., Bindu, L., Tran, T. H., Gillette, W. K., Frank, P. H., Ghirlando, R., Nissley, D. V., Esposito, D., McCormick, F., Stephen, A. G., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1615316113 · Cited by 173
Self-citationTran, N. T., Lecomte, E., Saleun, S., Namkung, S., Robin, C., Weber, K., Devine, E., Blouin, V., Adjali, O., Ayuso, E., et al. (2022) · Human Gene Therapy · doi:10.1089/hum.2022.050 · Cited by 74
HIV-1 matrix-tRNA complex structure reveals basis for host control of Gag localization
Bou-Nader, C., Muecksch, F., Brown, J. B., Gordon, J. M., York, A., Peng, C., Ghirlando, R., Summers, M. F., Bieniasz, P. D., & Zhang, J. (2021) · Cell Host & Microbe · doi:10.1016/j.chom.2021.07.006 · Cited by 48
Self-citationLi, M., Yang, R., Chen, X., Wang, H., Ghirlando, R., Dimitriadis, E. K., & Craigie, R. (2024) · Journal of Molecular Biology · doi:10.1016/j.jmb.2024.168557 · Cited by 18
“Time-stamp corrected data were analyzed in SEDFIT 18,19 with excellent fits.”
MethodSelf-citation
Metadata
- Authors
- Zhao, H., Ghirlando, R., Piszczek, G., Curth, U., Brautigam, C. A., & Schuck, P.
- Venue
- Analytical Biochemistry
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 437
- Issue
- 1
- Pages
- 104-108
- ISSN
- 0003-2697 (ISSN-L)
- OpenAlex
- W2033789454
- Cited by
- 102
- References
- 0
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.