Cited by 71Analytical chemistry methods developmentAnalytical Chemistry and ChromatographyToxic Organic Pollutants Impact

Dispersive liquid–liquid microextraction combined with gas chromatography–electron capture detection for the determination of polychlorinated biphenyls in soils

Hu, Jia, Fu, Lingyan, Zhao, Xinna, Liu, Xiujuan, Wang, Huili, Wang, Xuedong, Dai, Liyan·2009·Analytica Chimica Acta

Abstract

In this article, dispersive liquid-liquid microextraction (DLLME) and gas chromatography-electron capture detection (GC-ECD) were presented for the extraction and determination of five polychlorinated biphenyls (PCBs) in soil samples. Acetone was used as extraction solvent for the extraction of PCBs from soil samples. In DLLME, the target analytes in the extraction solvent were rapidly transferred from the acetone extract to chlorobenzene when the extraction process began. The main advantages of this method are quick speed, high enrichment factor, high recovery and good repeatability. Under the optimum conditions, the method yields a linear calibration curve in the concentration range from 2 to 2000 microg kg(-1)for PCB 52, and 0.4 to 400 microg kg(-1) for other target analytes. Coefficients of correlation (r(2)) ranged from 0.9993 to 0.9999. The repeatability was tested by spiking soil samples at a concentration level of 10 microg kg(-1) for PCBs. The relative standard deviations (RSDs, n=11) varied between 2.2% and 6.4%. The limits of detection (LODs), based on signal-to-noise (S/N) of 3, were between 0.20 and 0.50 microg kg(-1). The relative recoveries of the five PCBs from soil S1, S2 and S3 at spiking levels of 10, 20 and 50 microg kg(-1) were in the range of 88.70-103.8%, 82.50-106.3% and 82.30-113.6%, respectively. Therefore, DLLME combined with GC-ECD can be successfully applied for the determination of trace PCB residues in real soil samples.

Integrity signals

Registry

Crossref · 10.1016/j.aca.2009.02.055

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Only on a few occasions were complex samples analyzed for PCBs/PBDEs, such as soils or aquatic organisms.

    “From Table 3, it is clear that only on a few occasions were there analyses of complex samples {e.g., soils [60] or aquatic organisms in which bioaccumulation of these analytes may occur [59,61]}.”
  • Chlorobenzene and tetrachloroethane were preferred as extractant solvents for PCBs/PBDEs, while acetonitrile and acetone were used as disperser solvents, except one case using tetrahydrofurane.

    “Chlorobenzene [59-61,77] and tetrachloroethane [56,76,78] were preferred in all cases as extractant solvents (volumes less than 35 l L), while acetonitrile [56,76] and acetone [5961,77] were used as disperser solvent, except in one case in which tetrahydrofurane was used [78].”
  • So far, DLLME has been used for determination of PCBs by HPLC-UV and PBDEs by GC-ECD and GC-MS.

    “So far, the technique has been used for the determination of PCBs by HPLC-UV [76-78] and PBDEs by GC-ECD [56,59,60,72] and GCMS [61].”

The citation lists haven’t been fetched yet

References 31 · Cited by 71

Authors
Hu, J., Fu, L., Zhao, X., Liu, X., Wang, H., Wang, X., & Dai, L.
Affiliations
  • Central China Normal University (CN)
  • Wenzhou Medical University (CN)
  • Zhejiang University (CN)
Corresponding author
Dai, Liyan
Venue
Analytica Chimica Acta
Publisher
Elsevier BV
Published
2009-04
Volume
640
Issue
1-2
Pages
100-105
ISSN
0003-2670 (ISSN-L)
OpenAlex
W2131313913
Cited by
71
References
31
Citations by year
2025: 1 · 2024: 3 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 3 · 2016: 4 · 2015: 4 · 2014: 5 · 2013: 9 · 2012: 13
FWCI
11.52
Type
journal article
Language
en
Open access
closed
Locations
  • Analytica Chimica Acta (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Toxic Organic Pollutants Impact
Keywords
polychlorinated biphenyls, dispersive liquid-liquid microextraction, gas chromatography with electron capture detection, soil contamination, acetone extraction, chlorobenzene, preconcentration
MeSH terms
Chromatography, Gas, Electrons, Environmental Pollutants, Chemical Fractionation, Osmolar Concentration, Polychlorinated Biphenyls, Sensitivity and Specificity, Soil, Solvents, Time Factors, Analytic Sample Preparation Methods

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review