The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Reduced graphene oxide/nile blue/gold nanoparticles complex-modified glassy carbon electrode used as a sensitive and label-free aptasensor for ratiometric electrochemical sensing of dopamine
Abstract
In this work, glassy carbon electrode (GCE) surface was modified by drop-coating graphene oxide (GO) and nile blue (NB) to form GO/NB/GCE. By using a one-step coreduction treatment under cyclic voltammetry (CV) scanning, gold nanoparticles (AuNPs) were electrodeposited onto GO/NB/GCE surface, simultaneously generating reduced GO (rGO). AuNPs from the prepared rGO/NB/AuNPs/GCE was combined with 5'-SH-terminated aptamer of dopamine (DA) via Au-S coupling to fabricate aptamer-rGO/NB/AuNPs/GCE system. DA specifically combined with its aptamer modified on rGO/NB/AuNPs/GCE surface. CV, electrochemical impedance spectroscopy, square wave voltammetry responses of this system as the working electrode were measured. With the addition of DA, the peak current intensities located at -0.45 V (INB) and 0.15 V (IDA) showed gradually decreased and increased changes, respectively. There was a good linear (R2 = 0.9922) relationship between lg(IDA/INB) and the logarithm of DA concentration (lgCDA) in the CDA range from 10 nM to 0.2 mM, showing a low detection limit of 1 nM. This system as a novel, sensitive and label-free aptasensor was used for ratiometric electrochemical sensing of DA. Experimental results verified that this aptasensor possessed high stability, selectivity and sensitivity towards DA detection, over potential interferents. This aptasensor efficiently determined DA in real biological samples, together with high detection recoveries of 97.0-104.0%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noncovalent sidewall functionalization of single-walled carbon nanotubes for protein immobilization
Chen, R. J., Zhang, Y., Wang, D., & Dai, H. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010172b · Cited by 2,534
Cited by
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Supramolecular Luminescent Sensors
Mako, T. L., Racicot, J. M., & Levine, M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00260 · Cited by 735
Biosensors and sensors for dopamine detection
Liu, X., & Liu, J. (2021) · VIEW · doi:10.1002/viw.20200102 · Cited by 329
Metadata
- Authors
- Jin, H., Zhao, C., Gui, R., Gao, X., & Wang, Z.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 1025
- Pages
- 154-162
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2795122808
- Cited by
- 165
- References
- 1
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.