Recent advances in electrochemical non-enzymatic glucose sensors – A review
Abstract
This review encompasses the mechanisms of electrochemical glucose detection and recent advances in non-enzymatic glucose sensors based on a variety of materials ranging from platinum, gold, metal alloys/adatom, non-precious transition metal/metal oxides to glucose-specific organic materials. It shows that the discovery of new materials based on unique nanostructures have not only provided the detailed insight into non-enzymatic glucose oxidation, but also demonstrated the possibility of direct detection in whole blood or interstitial fluids. We critically evaluate various aspects of non-enzymatic electrochemical glucose sensors in terms of significance as well as performance. Beyond laboratory tests, the prospect of commercialization of non-enzymatic glucose sensors is discussed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Non-enzymatic sensors and methods for glucose monitoring in alternative biofluids have been developed to address limitations of enzyme-based sensors.
“To account for these limitations, non-enzymatic sensors, and methodology for glucose monitoring in alternative biofluids, rather than blood, have been developed 9.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [9]
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210 · see citing works
“Despite the chief motive of this review is to provide a multidisciplinary approach for a wide audience in the technical/clinical field, being a highly attractive area, a vast literature is witnessed by systematic readings that can be reached to deepen technological advancements on enzymatic, nonenzymatic, and optical…”
BackgroundMethod
- Authors
- Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D.
- Affiliations
- Seoul National University (KR)
- Seoul National University Hospital Biomedical Research Institute (KR)
- Corresponding author
- Chung, Taek Dong
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 1033
- Pages
- 1-34
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2803548015
- Cited by
- 788
- References
- 1
- Citations by year
- 2026: 49 · 2025: 81 · 2024: 89 · 2023: 106 · 2022: 125 · 2021: 115 · 2020: 133 · 2019: 82 · 2018: 6
- FWCI
- 4.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytica Chimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Research Foundation of Korea(NRF)
- Ministry of Science, ICT and Future Planning (2011-0030268)
- Defense Acquisition Program Administration (UD140069ID)
- National Research Foundation of Korea (NRF) (2017R1E1A1A01074236)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Electrocatalysts for Energy Conversion
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- non-enzymatic glucose sensor, electrochemical glucose detection, glucose oxidation, nanostructured materials, platinum electrode, gold electrode, alloys, metal oxides, whole blood glucose, interstitial fluid, commercialization
- MeSH terms
- Glucose, Biosensing Techniques, Extracellular Fluid, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review