The impact of signal pre-processing on the final interpretation of analytical outcomes – A tutorial
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The present tutorial paper is aimed to analyse and critically discuss the consequences of row pre-processing (conversion of measurement units, derivatives, and standard normal variate transform) on the evaluation of final outcomes of chemometric data analysis. An in-depth focus on pre-processing effects both on the signal shape and on misinterpretation of results - a crucial and disregarded issue in the analytical field - is presented. It is shown how this preliminary step of data processing may lead, in many cases, to draw incongruous conclusions, not actually based on real information embodied within data, but on artefacts arising from the mathematical transforms. This tutorial is not limited to a description of the problem, it also introduces strategies and tools for overcoming such unwanted effects, allowing a direct interpretation of the importance of original variables to be performed, explaining the chemical information that actually characterises samples. The dangerous implications of row pre-processing on instrumental signals is demonstrated on real datasets coming from different analytical techniques: transmission and attenuated total reflection infrared spectroscopy, cyclic voltammetry, X-ray fluorescence spectroscopy, Raman spectroscopy, and ultraviolet-visible spectroscopy. Hence, the impact of this widespread problem in most of the branches of analytical chemistry is illustrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Standard Normal Variate Transformation and De-Trending of Near-Infrared Diffuse Reflectance Spectra
Barnes, R. J., Dhanoa, M. S., & Lister, S. J. (1989) · Applied Spectroscopy · doi:10.1366/0003702894202201 · Cited by 3,867
The Statistical Analysis of Compositional Data
Aitchison, J. (1982) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1982.tb01195.x · Cited by 3,405
Dieterle, F., Ross, A., Schlotterbeck, G., & Senn, H. (2006) · Analytical Chemistry · doi:10.1021/ac051632c · Cited by 1,768
Nielsen, N.-P. V., Carstensen, J. M., & Smedsgaard, J. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00021-1 · Cited by 760
Raman and infrared spectra of carbonates of calcite structure
Gunasekaran, S., Anbalagan, G., & Pandi, S. (2006) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1518 · Cited by 729
Breaking with trends in pre-processing?
Engel, J., Gerretzen, J., Szymańska, E., Jansen, J. J., Downey, G., Blanchet, L., & Buydens, L. M. C. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.04.015 · Cited by 529
Compositional data and their analysis: an introduction
Pawlowsky-Glahn, V., & Egozcue, J. J. (2006) · Geological Society, London, Special Publications · doi:10.1144/gsl.sp.2006.264.01.01 · Cited by 418
icoshift: An effective tool for the alignment of chromatographic data
Tomasi, G., Savorani, F., & Engelsen, S. B. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.08.086 · Cited by 248
State-of-the art data normalization methods improve NMR-based metabolomic analysis
Kohl, S. M., Klein, M. S., Hochrein, J., Oefner, P. J., Spang, R., & Gronwald, W. (2012) · Metabolomics · doi:10.1007/s11306-011-0350-z · Cited by 227
Cited by
Li, Y., Shen, Y., Yao, C.-L., & Guo, D.-A. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113215 · Cited by 198
Metadata
- Authors
- Oliveri, P., Malegori, C., Simonetti, R., & Casale, M.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 1058
- Pages
- 9-17
- ISSN
- 0003-2670 (ISSN-L)
- OpenAlex
- W2898534989
- Cited by
- 198
- References
- 19
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.