A novel approach for adapting the standard addition method to single particle-ICP-MS for the accurate determination of NP size and number concentration in complex matrices
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents a novel approach, based on the standard addition method, for overcoming the matrix effects that often hamper the accurate characterization of nanoparticles (NPs) in complex samples via single particle inductively coupled plasma mass spectrometry (SP-ICP-MS). In this approach, calibration of the particle size is performed by two different methods: (i) by spiking a suspension of NPs standards of known size containing the analyte, or (ii) by spiking the sample with ionic standards; either way, the measured sensitivity is used in combination with the transport efficiency (TE) for sizing the NPs. Moreover, such transport efficiency can be readily obtained from the data obtained via both calibration methods mentioned above, so that the particle number concentration can also be determined. The addition of both ionic and NP standards can be performed on-line, by using a T-piece with two inlet lines of different dimensions. The smaller of the two is used for the standards, thus ensuring a constant and minimal sample dilution. As a result of the spiking of the samples, mixed histograms including the signal of the sample and that of the standards are obtained. However, the use of signal deconvolution approaches permits to extract the information, even in cases of signal populations overlapping. For proofing the concept, characterization of a 50 nm AuNPs suspension prepared in three different media (i.e., deionized water, 5% ethanol, and 2.5% tetramethyl ammonium hydroxide-TMAH) was carried out. Accurate results were obtained in all cases, in spite of the matrix effects detected in some media. Overall, the approach proposed offers flexibility, so it can be adapted to different situations, but it might be specially indicated for samples for which the matrix is not fully known and/or dilution is not possible/recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Other strategies to handle the matrix effects are based on using a higher dilution factor when the number of particles is high, internal standardization, and standard addition [49][50][51].”
From Tracing isotopically labeled selenium nanoparticles in plants via single-particle ICP-mass spectrometry (2024) · cites this paper as [51]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
De la Calle, I., Menta, M., & Séby, F. (2016) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2016.09.007 · Cited by 99
Research works printed but not linked: 26
- Laborda, 2014, Single particle inductively coupled plasma mass spectrometry: a powerful tool for nanoanalysis, Anal. Chem., 86, 2270, 10.1021/ac402980q · DOI · Paper page
- Krystek, 2011, Application of plasma spectrometry for the analysis of engineered nanoparticles in suspensions and products, J. Anal. Atom. Spectrom., 26, 1701, 10.1039/c1ja10071h · DOI
- Mitrano, 2014, Tracking dissolution of silver nanoparticles at environmentally relevant concentrations in laboratory, natural, and processed waters using single particle ICP-MS (spICP-MS), Environ. Sci. Nano., 1, 248, 10.1039/C3EN00108C · DOI
- Laborda, 2016, Single particle inductively coupled plasma mass spectrometry for the analysis of inorganic engineered nanoparticles in environmental samples, Trends Environ. Anal. Chem., 9, 15, 10.1016/j.teac.2016.02.001 · DOI
- Mozhayeva, 2020, A critical review of single particle inductively coupled plasma mass spectrometry – a step towards an ideal method for nanomaterial characterization, J. Anal. Atom. Spectrom., 35, 10.1039/C9JA00206E · DOI · Paper page
- Montaño, 2016, Single Particle ICP-MS: advances toward routine analysis of nanomaterials, Anal. Bioanal. Chem., 408, 5053, 10.1007/s00216-016-9676-8 · DOI
- Liu, 2017, Overcoming challenges in single particle inductively coupled plasma mass spectrometry measurement of silver nanoparticles, Anal. Bioanal. Chem., 409, 6027, 10.1007/s00216-017-0530-4 · DOI
- Hendriks, 2019, Single-particle ICP-MS with online microdroplet calibration: toward matrix independent nanoparticle sizing, J. Anal. Atom. Spectrom., 34, 716, 10.1039/C8JA00397A · doi:10.1039/c8ja00397a
- Bolea-Fernández, 2017, Characterization of SiO2 nanoparticles by single particle-inductively coupled plasma-tandem mass spectrometry (SP-ICP-MS/MS), J. Anal. Atom. Spectrom., 32, 2140, 10.1039/C7JA00138J · DOI
- Bolea-Fernandez, 2019, On the effect of using collision/reaction cell (CRC) technology in single-particle ICP-mass spectrometry (SP-ICP-MS), Anal. Chim. Acta, 1077, 95, 10.1016/j.aca.2019.05.077 · DOI · Paper page
- Rua-Ibarz, 2020, Characterization of iron oxide nanoparticles by means of single-particle ICP-mass spectrometry (SP-ICP-MS) – chemical versus physical resolution to overcome spectral overlap, J. Anal. Atom. Spectrom., 35, 2023, 10.1039/D0JA00183J · DOI
- Pace, 2011, Determining transport efficiency for the purpose of counting and sizing nanoparticles via single particle inductively coupled plasma mass spectrometry, Anal. Chem., 83, 9361, 10.1021/ac201952t · DOI · Paper page
- Olesik, 2012, Considerations for measurement of individual nanoparticles or microparticles by ICP-MS: determination of the number of particles and the analyte mass in each particle, J. Anal. Atom. Spectrom., 27, 1143, 10.1039/c2ja30073g · DOI
- Loula, 2019, Non-spectral interferences in single-particle ICP-MS analysis_ an underestimated phenomenon, Talanta, 202, 565, 10.1016/j.talanta.2019.04.073 · doi:10.1016/j.talanta.2019.04.073
- Miyashita, 2017, High transport efficiency of nanoparticles through a total-consumption sample introduction system and its beneficial application for particle size evaluation in single-particle ICP-MS, Anal. Bioanal. Chem., 409, 1, 10.1007/s00216-016-0089-5 · doi:10.1007/s00216-016-0089-5
- Ramkorun-Schmidt, 2015, Investigation of a combined microdroplet generator and pneumatic nebulization system for quantitative determination of metal-containing nanoparticles using ICPMS, Anal. Chem., 87, 8687, 10.1021/acs.analchem.5b01604 · DOI
- Rosenkranz, 2020, Improved validation for single particle ICP-MS analysis using a pneumatic nebulizer/microdroplet generator sample introduction system for multi-mode nanoparticle determination, Anal. Chim. Acta, 1099, 16, 10.1016/j.aca.2019.11.043 · doi:10.1016/j.aca.2019.11.043
- Meermann, 2018, ICP-MS for the analysis at the nanoscale – a tutorial review, J. Anal. Atom. Spectrom., 33, 1432, 10.1039/C8JA00037A · DOI · Paper page
- Agatemor, 2011, Matrix effects in inductively coupled plasma mass spectrometry: a review, Anal. Chim. Acta, 706, 66, 10.1016/j.aca.2011.08.027 · doi:10.1016/j.aca.2011.08.027
- Sötebier, 2016, Combination of single particle ICP-QMS and isotope dilution analysis for the determination of size, particle number and number size distribution of silver nanoparticles, J. Anal. Atom. Spectrom., 31, 2045, 10.1039/C6JA00137H · doi:10.1039/c6ja00137h
- Telgmann, 2014, Rapid size characterization of silver nanoparticles by single particle ICP-MS and isotope dilution, J. Anal. Atom. Spectrom., 29, 1265, 10.1039/C4JA00115J · doi:10.1039/c4ja00115j
- Vidmar, 2018, Comparison of the suitability of alkaline or enzymatic sample pre-treatment for characterization of silver nanoparticles in human tissue by single particle ICP-MS, J. Anal. Atom. Spectrom., 33, 752, 10.1039/C7JA00402H · DOI
- Abad-Alvaro, 2021, An insight into the determination of size and number concentration of silver nanoparticles in blood using single particle ICP-MS (spICP-MS): feasibility of application to samples relevant to in vivo toxicology studies, J. Anal. Atom. Spectrom., 36, 1180, 10.1039/D1JA00068C · DOI
- Bolea, 2014, Detection and characterization of silver nanoparticles and dissolved species of silver in culture medium and cells by AsFlFFF-UV-Vis-ICPMS: application to nanotoxicity tests, Analyst, 139, 914, 10.1039/C3AN01443F · DOI
- Lee, 2015, Calibration of single-particle inductively coupled plasma-mass spectrometry (SP-ICP-MS), J. Anal. Atom. Spectrom., 30, 1245, 10.1039/C4JA00408F · DOI
- Cuello-Nuñez, 2020, The accurate determination of number concentration of inorganic nanoparticles using spICP-MS with the dynamic mass flow approach, J. Anal. Atom. Spectrom., 35, 1832, 10.1039/C9JA00415G · doi:10.1039/c9ja00415g
Cited by
Freire, B. M., Rua-Ibarz, A., Nakadi, F. V., Bolea-Fernandez, E., Barriuso-Vargas, J. J., Lange, C. N., Aramendía, M., Batista, B. L., & Resano, M. (2024) · Talanta · doi:10.1016/j.talanta.2024.126417 · Cited by 17
Self-citation
Metadata
- Authors
- Aramendía, M., García-Mesa, J. C., Alonso, E. V., Garde, R., Bazo, A., Resano, J., & Resano, M.
- Venue
- Analytica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2022-05
- Volume
- 1205
- Pages
- 339738
- ISSN
- 0003-2670
- Cited by
- 30
- References
- 1
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor)
- Funders
- España Ministerio de Ciencia Innovación y Universidades (PGC2018-093753-B-I00)
- European Commission (PID2019-105660RB-C21/AEI/10.13039/501100011033)
- European Regional Development Fund
- Gobierno de Aragón
- Junta de Andalucía (UMA18FEDERJA060)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.