CoChat

Effect of CAD on Radiologists' Detection of Lung Nodules on Thoracic CT Scans: Analysis of an Observer Performance Study by Nodule Size

Open access
Sahiner, Berkman, Chan, Heang-Ping, Hadjiiski, Lubomir M., Cascade, Philip N., Kazerooni, Ella A., Chughtai, Aamer R., Poopat, Chad, Song, Thomas, Frank, Luba, Stojanovska, Jadranka, Attili, Anil · 2009 · Academic Radiology
Cited by 130

The DOI matches its Crossref record.

Abstract

Rationale and Objectives To retrospectively investigate the effect of a computer aided detection (CAD) system on radiologists’ performance for detecting small pulmonary nodules in CT examinations, with a panel of expert radiologists serving as the reference standard. Materials and Methods Institutional review board approval was obtained. Our data set contained 52 CT examinations collected by the Lung Image Database Consortium, and 33 from our institution. All CTs were read by multiple expert thoracic radiologists to identify the reference standard for detection. Six other thoracic radiologists read the CT examinations first without, and then with CAD. Performance was evaluated using free-response receiver operating characteristics (FROC) and the jackknife FROC analysis methods (JAFROC) for nodules above different diameter thresholds. Results 241 nodules, ranging in size from 3.0 to 18.6 mm (mean 5.3 mm) were identified as the reference standard. At diameter thresholds of 3, 4, 5, and 6 mm, the CAD system had a sensitivity of 54%, 64%, 68%, and 76%, respectively, with an average of 5.6 false-positives (FPs) per scan. Without CAD, the average figures-of-merit (FOMs) for the six radiologists, obtained from JAFROC analysis, were 0.661, 0.729, 0.793 and 0.838 for the same nodule diameter thresholds, respectively. With CAD, the corresponding average FOMs improved to 0.705, 0.763, 0.810 and 0.862, respectively. The improvement achieved statistical significance for nodules at the 3 and 4 mm thresholds (p=0.002 and 0.020, respectively), and did not achieve significance at 5 and 6 mm (p=0.18 and 0.13, respectively). At a nodule diameter threshold of 3 mm, the radiologists’ average sensitivity and FP rate were 0.56 and 0.67, respectively, without CAD, and 0.67 and 0.78 with CAD. Conclusion CAD improves thoracic radiologists’ performance for detecting pulmonary nodules under 5 mm on CT examinations, which are often overlooked by visual inspection alone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.acra.2009.08.006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Sahiner, B., Chan, H.-P., Hadjiiski, L. M., Cascade, P. N., Kazerooni, E. A., Chughtai, A. R., Poopat, C., Song, T., Frank, L., Stojanovska, J., & Attili, A.
Venue
Academic Radiology
Publisher
Elsevier BV
Published
2009-12
Volume
16
Issue
12
Pages
1518-1530
ISSN
1076-6332 (ISSN-L)
OpenAlex
W1986050565
Cited by
130
References
0
FWCI
4.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.