Abstract
Computational modelling to calculate the mechanical loading within atherosclerotic plaques has been shown to be complementary to defining anatomical plaque features in determining plaque vulnerability. However, its application has been partially impeded by the lack of comprehensive knowledge about the mechanical properties of various tissues within the plaque. Twenty-one human carotid plaques were collected from endarterectomy. The plaque was cut into rings, and different type of atherosclerotic tissues, including media, fibrous cap (FC), lipid and intraplaque haemorrhage/thrombus (IPH/T) was dissected for uniaxial extension testing. In total, 65 media strips from 17 samples, 59 FC strips from 14 samples, 38 lipid strips from 11 samples, and 21 IPH/T strips from 11 samples were tested successfully. A modified Mooney-Rivlin strain energy density function was used to characterize the stretch-stress relationship. The stiffnesses of media and FC are comparable, as are lipid and IPH/T. However, both media and FC are stiffer than either lipid or IPH/T. The median values of incremental Young's modulus of media, FC, lipid and IPH/T at λ=1 are 290.1, 244.5, 104.4, 52.9, respectively; they increase to 1019.5, 817.4, 220.7 and 176.9 at λ=1.1; and 4302.7, 3335.0, 533.4 and 268.8 at λ=1.15 (unit, kPa; λ, stretch ratio). The material constants of each tissue type are suggested to be: media, c1=0.138kPa, D1=3.833kPa and D2=18.803; FC, c1=0.186kPa, D1=5.769kPa and D2=18.219; lipid, c1=0.046kPa, D1=4.885kPa and D2=5.426; and IPH/T, c1=0.212kPa, D1=4.260kPa and D2=5.312. It is concluded that all soft atherosclerotic tissues are non-linear, and both media and FC are stiffer than either lipid or IPH/T.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Material stiffness influences the polarization state, function and migration mode of macrophages
Sridharan, R., Cavanagh, B., Cameron, A. R., Kelly, D. J., & O'Brien, F. J. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.02.048 · Cited by 450
Role of biomechanical forces in the natural history of coronary atherosclerosis
Brown, A. J., Teng, Z., Evans, P. C., Gillard, J. H., Samady, H., & Bennett, M. R. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2015.203 · Cited by 271
Self-citationPrevitera, M. L., & Sengupta, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0145813 · Cited by 176
“Tissues that are within this range of stiffness include human spinal cord (89 kPa), human collagenous bone (<34 kPa), atherosclerotic tissue (54– 290 kPa), human thyroid cancer tissue (45 kPa), rodent myocardial infarct tissue (55 kPa), and rodent skeletal muscle (100 kPa) [3,10,35,36,37].”
BackgroundMatrix stiffness regulates macrophage polarisation via the Piezo1‐YAP signalling axis
Mei, F., Guo, Y., Wang, Y., Zhou, Y., Heng, B. C., Xie, M., Huang, X., Zhang, S., Ding, S., Liu, F., et al. (2024) · Cell Proliferation · doi:10.1111/cpr.13640 · Cited by 118
Suri, J. S., Bhagawati, M., Paul, S., Protogerou, A. D., Sfikakis, P. P., Kitas, G. D., Khanna, N. N., Ruzsa, Z., Sharma, A. M., Saxena, S., et al. (2022) · Diagnostics · doi:10.3390/diagnostics12030722 · Cited by 55
Metadata
- Authors
- Teng, Z., Zhang, Y., Huang, Y., Feng, J., Yuan, J., Lu, Q., Sutcliffe, M. P. F., Brown, A. J., Jing, Z., & Gillard, J. H.
- Venue
- Acta Biomaterialia
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 10
- Issue
- 12
- Pages
- 5055-5063
- ISSN
- 1742-7061 (ISSN-L)
- OpenAlex
- W1966164421
- Cited by
- 112
- References
- 0
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Material properties of components in human carotid atherosclerotic plaques: A uniaxial extension study. https://app.cochat.ai/papers/10.1016/j.actbio.2014.09.001
- The paper
- Teng, Z., Zhang, Y., Huang, Y., Feng, J., Yuan, J., Lu, Q., Sutcliffe, M. P. F., Brown, A. J., Jing, Z., & Gillard, J. H. (2014). Material properties of components in human carotid atherosclerotic plaques: A uniaxial extension study. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2014.09.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.