Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 171

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Long-term in vivo study of biodegradable Zn-Cu stent: A 2-year implantation evaluation in porcine coronary artery

Zhou, Chao, Li, Hua-Fang, Yin, Yu-Xia, Shi, Zhang-Zhi, Li, Ting, Feng, Xiang-Yi, Zhang, Jun-Wei, Song, Cai-Xia, Cui, Xiao-Shan, Xu, Kai-Li, Zhao, Yan-Wei, Hou, Wen-Bo, Lu, Shou-Tao, Liu, Guang, Li, Mao-Quan, Ma, Jian-ying, Toft, Egon, Volinsky, Alex A., Wan, Min, Yao, Xiu-jun, Wang, Chang-bin, Yao, Kang, Xu, Shi-kun, Lu, Hao, Chang, Shu-Fu, Ge, Jun-Bo, Wang, Lu-Ning, Zhang, Hai-Jun · 2019 · Acta Biomaterialia

Abstract

In the present study, a novel biodegradable Zn-0.8Cu coronary artery stent was fabricated and implanted into porcine coronary arteries for up to 24 months. Micro-CT analysis showed that the implanted stent was able to maintain structural integrity after 6 months, while its disintegration occurred after 9 months of implantation. After 24 months of implantation, approximately 28±13 vol.% of the stent remained. Optical coherence tomography and histological analysis showed that the endothelialization process could be completed within the first month after implantation, and no inflammation responses or thrombosis formation was observed within 24 months. Cross-section analysis indicated that the subsequent degradation products had been removed in the abluminal direction, guaranteeing that the strut could be replaced by normal tissue without the risk of contaminating the circulatory system, causing neither thrombosis nor inflammation response. The present work demonstrates that the Zn-0.8Cu stent has provided sufficient structural supporting and exhibited an appropriate degradation rate during 24 months of implantation without degradation product accumulation, thrombosis, or inflammation response. The results indicate that the Zn-0.8Cu coronary artery stent is promising for further clinical applications. Statement of significance Although Zn and its alloys have been considered to be potential candidates of biodegradable metals for vascular stent use, by far there is no Zn-based stent with proper medical device performance has been reported because of the low mechanical properties of zinc. The present work describes promising results about a Zn-Cu biodegradable vascular stent in porcine coronary arteries. The Zn-Cu stent fabricated in this work obtained a quite well medical device performance both in vitro and in vivo, and degraded with a proper rate without safety problems induced. Furthermore, large animal models have more cardiovascular similarities to humans. Results of this study may provide further information for the translational medicine research of the Zn-based stents.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.actbio.2019.08.012

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Metadata

Authors
Zhou, C., Li, H.-F., Yin, Y.-X., Shi, Z.-Z., Li, T., Feng, X.-Y., Zhang, J.-W., Song, C.-X., Cui, X.-S., Xu, K.-L., Zhao, Y.-W., Hou, W.-B., Lu, S.-T., Liu, G., Li, M.-Q., Ma, J.-Y., Toft, E., Volinsky, A. A., Wan, M., Yao, X.-J., Wang, C.-B., Yao, K., Xu, S.-K., Lu, H., Chang, S.-F., Ge, J.-B., Wang, L.-N., & Zhang, H.-J.
Venue
Acta Biomaterialia
Publisher
Elsevier BV
Published
2019-10
Volume
97
Pages
657-670
ISSN
1742-7061 (ISSN-L)
OpenAlex
W2967287193
Cited by
171
References
3
FWCI
12.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.