Cardiopulmonary exercise function among patients undergoing transcatheter pulmonary valve implantation in the US Melody valve investigational trial

Open access
Batra, Anjan S., McElhinney, Doff B., Wang, Wayne, Zakheim, Richard, Garofano, Robert P., Daniels, Curt, Yung, Delphine, Cooper, Dan M., Rhodes, Jonathan · 2012 · American Heart Journal
Cited by 62

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVES We assessed the hypothesis that there is an improvement in clinical and physiologic parameters of cardiopulmonary exercise testing (CPET) after implantation of a transcatheter pulmonary valve (TPV). BACKGROUND Transcatheter pulmonary valve provides a new tool for treating conduit stenosis and regurgitation in patients with right ventricle (RV) to pulmonary artery conduit dysfunction. METHODS Patients who underwent a TPV placement between January 2007 and January 2010 (N = 150) were investigated with a standardized CPET protocol before and at 6 months after TPV placement. Cardiopulmonary exercise testing was performed on a mechanically braked cycle ergometer with respiratory gas exchange analysis. RESULTS Six months post TPV, small but statistically significant improvements were observed in the maximum workload (65.0% ± 18.8% to 68.3% ± 20.3% predicted, P < .001) and the ratio of minute ventilation to CO(2) production at the anaerobic threshold (30.8 ± 4.7 to 29.1 ± 4.1, P < .001). There was no significant change in peak oxygen consumption (VO(2)). Patients with pre-TPV hemodynamics consistent with RV dysfunction and patients with a lower pre-TPV peak VO(2) tended to have the greatest improvement in peak VO(2). The correlation between TPV-related improvements in peak VO(2) and baseline clinical variables were weak, however, and these variables could not be used to reliably identify patients likely to have improved peak VO(2) after TPV. CONCLUSION In patients with RV to pulmonary artery conduit dysfunction, TPV is associated with modest improvement in exercise capacity and gas exchange efficiency during exercise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ahj.2011.10.017

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 62

Metadata

Authors
Batra, A. S., McElhinney, D. B., Wang, W., Zakheim, R., Garofano, R. P., Daniels, C., Yung, D., Cooper, D. M., & Rhodes, J.
Venue
American Heart Journal
Publisher
Elsevier BV
Published
2012-02
Volume
163
Issue
2
Pages
280-287
ISSN
0002-8703 (ISSN-L)
OpenAlex
W1968426061
Cited by
62
References
4
FWCI
4.95
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiopulmonary exercise function among patients undergoing transcatheter pulmonary valve implantation in the US Melody valve investigational trial. https://app.cochat.ai/papers/10.1016/j.ahj.2011.10.017
The paper
Batra, A. S., McElhinney, D. B., Wang, W., Zakheim, R., Garofano, R. P., Daniels, C., Yung, D., Cooper, D. M., & Rhodes, J. (2012). Cardiopulmonary exercise function among patients undergoing transcatheter pulmonary valve implantation in the US Melody valve investigational trial. American Heart Journal. https://doi.org/10.1016/j.ahj.2011.10.017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.