Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background Organizations are stockpiling respirators to prepare for an influenza pandemic. To understand better the effects of prolonged storage, this investigation evaluated the filtration efficiency of 21 different models of National Institute for Occupational Safety and Health (NIOSH)-certified disposable N95 filtering face piece respirators. These respirators had been stored in their original packaging for a period of at least 6 years in research laboratories and dry warehouse facilities, ranging in temperature between 15°C and 32°C and relative humidity between 20% and 80%. Methods Filter penetration was measured using an abbreviated version of the NIOSH respirator certification test incorporating a polydisperse sodium chloride aerosol at 85 L/min. Results Of the 21 respirator models tested, 19 models had both average penetration results of less than 5%. Mean initial penetration values ranged from 0.39% to 5.83%, whereas mean maximum penetration values ranged from 0.95% to 5.83%. There did not appear to be any correlation between the length of storage and failure to pass the filtration test. Conclusion Results indicate that most N95 filtering face piece respirators stored for up to 10 years at warehouse conditions will likely have expected levels of filtration performance and that the degree of filtration efficiency degradation is likely model specific.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrostatic Respirator Filter Media: Filter Efficiency and Most Penetrating Particle Size Effects
Martin, S. B., & Moyer, E. S. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220050075617 · Cited by 156
Cited by
Physical interventions to interrupt or reduce the spread of respiratory viruses
Jefferson, T., Del Mar, C. B., Dooley, L., Ferroni, E., Al-Ansary, L. A., Bawazeer, G. A., van Driel, M. L., Nair, N. S., Jones, M. A., Thorning, S., et al. (2011) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006207.pub4 · Cited by 805
Rowan, N. J., & Laffey, J. G. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.138532 · Cited by 432
Evaluation of Five Decontamination Methods for Filtering Facepiece Respirators
(2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mep070 · Cited by 339
Physical interventions to interrupt or reduce the spread of respiratory viruses
Jefferson, T., Del Mar, C. B., Dooley, L., Ferroni, E., Al-Ansary, L. A., Bawazeer, G. A., van Driel, M. L., Jones, M. A., Thorning, S., Beller, E. M., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006207.pub5 · Cited by 318
Physical interventions to interrupt or reduce the spread of respiratory viruses
Jefferson, T., Dooley, L., Ferroni, E., Al-Ansary, L. A., van Driel, M. L., Bawazeer, G. A., Jones, M. A., Hoffmann, T. C., Clark, J., Beller, E. M., et al. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006207.pub6 · Cited by 291
Metadata
- Authors
- Viscusi, D. J., Bergman, M., Sinkule, E., & Shaffer, R. E.
- Venue
- American Journal of Infection Control
- Publisher
- Elsevier BV
- Published
- 2009-06
- Volume
- 37
- Issue
- 5
- Pages
- 381-386
- ISSN
- 0196-6553 (ISSN-L)
- OpenAlex
- W2076773905
- Cited by
- 65
- References
- 1
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage. https://app.cochat.ai/papers/10.1016/j.ajic.2008.09.021
- The paper
- Viscusi, D. J., Bergman, M., Sinkule, E., & Shaffer, R. E. (2009). Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage. American Journal of Infection Control. https://doi.org/10.1016/j.ajic.2008.09.021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.