CoChat

Automated Diagnosis of Diabetic Retinopathy Using Clinical Biomarkers, Optical Coherence Tomography, and Optical Coherence Tomography Angiography

Sandhu, Harpal Singh, Elmogy, Mohammed, Taher Sharafeldeen, Ahmed, Elsharkawy, Mohamed, El-Adawy, Nabila, Eltanboly, Ahmed, Shalaby, Ahmed, Keynton, Robert, El-Baz, Ayman · 2020 · American Journal of Ophthalmology
Cited by 92

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

PURPOSE To determine if combining clinical, demographic, and imaging data improves automated diagnosis of nonproliferative diabetic retinopathy (NPDR). DESIGN Cross-sectional imaging and machine learning study. METHODS This was a retrospective study performed at a single academic medical center in the United States. Inclusion criteria were age > 18 and a diagnosis of diabetes mellitus (DM). Exclusion criteria were non-DR retinal disease and inability to image the macula. Optical coherence tomography (OCT) and OCT angiography (OCTA) were performed, and data on age, gender, hypertension, hyperlipidemia, and hemoglobin A1c were collected. Machine learning techniques were then applied. Multiple pathophysiologically important features were automatically extracted from each layer on OCT and each OCTA plexus and combined with clinical data in a random forest classifier to develop the system, whose results were compared to the clinical grading of NPDR, the gold standard. RESULTS 111 patients with DM II were included in the study, 36 with DM without DR, 53 with mild NPDR, and 22 with moderate NPDR. When OCT images alone were analyzed by the system, accuracy of diagnosis was 76%, sensitivity 85%, specificity 87%, and area under the curve (AUC) was 0.78. When OCT and OCTA data together were analyzed, accuracy was 92%, sensitivity 95%, specificity 98%, and AUC 0.92. When all data modalities were combined, the system achieved an accuracy of 96%, sensitivity 100%, specificity 94%, and AUC 0.96. CONCLUSIONS Combining common clinical data points with OCT and OCTA data enhances the power of computer-aided diagnosis of NPDR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ajo.2020.01.016

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 92

Metadata

Authors
Sandhu, H. S., Elmogy, M., Taher Sharafeldeen, A., Elsharkawy, M., El-Adawy, N., Eltanboly, A., Shalaby, A., Keynton, R., & El-Baz, A.
Venue
American Journal of Ophthalmology
Publisher
Elsevier BV
Published
2020-08
Volume
216
Pages
201-206
ISSN
0002-9394 (ISSN-L)
OpenAlex
W3002388361
Cited by
92
References
5
FWCI
6.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated Diagnosis of Diabetic Retinopathy Using Clinical Biomarkers, Optical Coherence Tomography, and Optical Coherence Tomography Angiography. https://app.cochat.ai/papers/10.1016/j.ajo.2020.01.016
The paper
Sandhu, H. S., Elmogy, M., Taher Sharafeldeen, A., Elsharkawy, M., El-Adawy, N., Eltanboly, A., Shalaby, A., Keynton, R., & El-Baz, A. (2020). Automated Diagnosis of Diabetic Retinopathy Using Clinical Biomarkers, Optical Coherence Tomography, and Optical Coherence Tomography Angiography. American Journal of Ophthalmology. https://doi.org/10.1016/j.ajo.2020.01.016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.