CoChat

TFOS DEWS III: Diagnostic Methodology

Open access
Wolffsohn, James S., Benítez-Del-Castillo, José M., Loya-Garcia, Denise, Inomata, Takenori, Iyer, Geetha, Liang, Lingyi, Pult, Heiko, Sabater, Alfonso L., Starr, Christopher E., Vehof, Jelle, Wang, Michael T.M., Chen, Wei, Craig, Jennifer P., Dogru, Murat, Perez, Victor L., Stapleton, Fiona, Sullivan, David A., Jones, Lyndon · 2025 · American Journal of Ophthalmology
Cited by 221

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

A standard approach to the diagnosis of dry eye disease across eye care practitioners is critical to reassuring the patient, providing consistency between practitioners and informing governments as to the true prevalence and resulting healthcare needs. The Tear Film & Ocular Surface Society (TFOS) Dry Eye Workshop (DEWS) III has reviewed the evidence-base since their previous reports published in 2017 and revised the definition to "Dry eye is a multifactorial, symptomatic disease characterized by a loss of homeostasis of the tear film and/or ocular surface, in which tear film instability and hyperosmolarity, ocular surface inflammation and damage, and neurosensory abnormalities are etiological factors." Key features from the definition include that dry eye disease is multifactorial, is a disease and not a syndrome and is always symptomatic. Differential diagnosis and ocular examination guidance is given along with the risk factors that should be discussed with the patient. The recommended screening questionnaire is the OSDI-6 with a cut-off score ≥4. A positive result together with a non-invasive breakup time <10s or alternatively tear film hyperosmolarity (≥308mOsm/L in either eye or an interocular difference >8mOsm/L) or alternatively >5 corneal fluorescein and/or >9 conjunctival lissamine green punctate spots and/or lid margin lissamine green staining of ≥2mm length & ≥25 % width, gives a diagnosis of dry eye. Subclassification was separated into tear film deficiencies (lipid, aqueous and mucin/glycocalyx), eyelid anomalies (blink/lid closure and lid margin) and ocular surface abnormalities (anatomical misalignment, neural dysfunction, ocular surface cell damage/disruption and primary inflammation/oxidative stress) components, with appropriate clinical tests and cut-offs provided to identify these etiological drivers in an individual, to inform appropriate management and therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ajo.2025.05.033

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Metadata

Authors
Wolffsohn, J. S., Benítez-Del-Castillo, J. M., Loya-Garcia, D., Inomata, T., Iyer, G., Liang, L., Pult, H., Sabater, A. L., Starr, C. E., Vehof, J., Wang, M. T. M., Chen, W., Craig, J. P., Dogru, M., Perez, V. L., Stapleton, F., Sullivan, D. A., & Jones, L.
Venue
American Journal of Ophthalmology
Publisher
Elsevier BV
Published
2025-11
Volume
279
Pages
387-450
ISSN
0002-9394 (ISSN-L)
OpenAlex
W4410883349
Cited by
221
References
6
FWCI
184.28
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: TFOS DEWS III: Diagnostic Methodology. https://app.cochat.ai/papers/10.1016/j.ajo.2025.05.033
The paper
Wolffsohn, J. S., Benítez-Del-Castillo, J. M., Loya-Garcia, D., Inomata, T., Iyer, G., Liang, L., Pult, H., Sabater, A. L., Starr, C. E., Vehof, J., Wang, M. T. M., Chen, W., Craig, J. P., Dogru, M., Perez, V. L., Stapleton, F., Sullivan, D. A., & Jones, L. (2025). TFOS DEWS III: Diagnostic Methodology. American Journal of Ophthalmology. https://doi.org/10.1016/j.ajo.2025.05.033

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.