Thin-film hydration preparation method and stability test of DOX-loaded disulfide-linked polyethylene glycol 5000-lysine-di-tocopherol succinate nanomicelles
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A novel redox-responsive PEG-sheddable copolymer of disulfide-linked polyethylene glycol 5000-lysine-di-tocopherol succinate (P 5k SSLV) was designed and synthesized. Thin-film hydration method was used to prepare DOX-loaded P 5k SSLV nanomicelle . To optimize the preparation technology, we investigate the effects of dosage, type of organic solvent, hydration temperature and time, and cryoprotectant on drug-loading content, encapsulation efficiency, particle size, and zeta potential . The mean particle size and zeta potential were determined by Zetasizer. The morphology of the P 5k SSLV-DOX nanomicelles was visualized by transmission electron microscopy . The drug-loading content and encapsulation efficiency of P 5k SSLV-DOX nanomicelle were investigated by UV. The drug-loading content, encapsulation efficiency, particle size, and zeta potential of the final optimized nanomicelles were 4.58%, 97.20%, 30.21 nm and −0.84 mV, respectively. In addition, the stability of nanomicelles was investigated, which included dilution stability and storage stability. The results showed that P 5k SSLV-DOX nanomicelle had good dilution stability and storage stability at 4 °C. The preparation method of P 5k SSLV-DOX nanomicelle with thin-film hydration method was practical and simple, which was valuable to be further studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mikhail, A. S., & Allen, C. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.04.010 · Cited by 328
Cited by
Yang, K., Liu, Y., Liu, Y., Zhang, Q., Kong, C., Yi, C., Zhou, Z., Wang, Z., Zhang, G., Zhang, Y., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b00884 · Cited by 166
Liposomal drug product development and quality: current US experience and perspective
Kapoor, M., Lee, S. L., & Tyner, K. M. (2017) · The AAPS Journal · doi:10.1208/s12248-017-0049-9 · Cited by 116
Ansari, M., Gupta, C., Kulkarni, Y. A., & Singh, K. (2025) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2025.125235 · Cited by 10
Sathe, P., Nagarjuna, V., Sharma, H., Velpandian, T., Garg, P., & Nirmal, J. (2025) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.5c00423 · Cited by 3
Metadata
- Authors
- Ai, X., Zhong, L., Niu, H., & He, Z.
- Venue
- Asian Journal of Pharmaceutical Sciences
- Publisher
- Elsevier BV
- Published
- 2014-10
- Volume
- 9
- Issue
- 5
- Pages
- 244-250
- ISSN
- 1818-0876 (ISSN-L)
- OpenAlex
- W1973183062
- Cited by
- 78
- References
- 1
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.