CoChat

Failure to Rescue, Hospital Volume, and In-Hospital Mortality After Transcatheter Aortic Valve Implantation

Ando, Tomo, Adegbala, Oluwole, Villablanca, Pedro A., Shokr, Mohamed, Akintoye, Emmanuel, Briasoulis, Alexandros, Takagi, Hisato, Schreiber, Theodore, Grines, Cindy L., Afonso, Luis · 2018 · The American Journal of Cardiology
Cited by 18

The DOI matches its Crossref record.

Abstract

Failure to rescue (FTR), death after major complications, has been well described in the surgical literature as a source of different outcomes in different hospitals. However, FTR has not been investigated in transcatheter aortic valve implantation (TAVI). Our aim was to assess the difference of in-patient mortality and FTR in different TAVI volume hospitals. We queried the Nationwide Inpatient Sample database from 2011 to 2015 to identify patients who had transarterial TAVI. FTR was calculated as those who had in-patient mortality with at least one with major perioperative complications. Hospitals were divided into three groups according to annual TAVI volume, the lowest quintile (≤30/year), second to fourth quintile (31 to 130/year), and highest quintile (≥130/year). Multivariate analysis was used to calculate risk adjusted in-patient mortality rate and FTR and was compared between these different volume hospitals. A total of 48,886 TAVI procedures were identified (10,407, 28,811, and 9,668 in low, intermediate, and high volume centers, respectively). Mean age, percentage of woman, and Elixhauser co-morbidity index was similar across different TAVI volume hospital. The incidence of major perioperative complications did not differ in different volume hospitals. Adjusted rate of in-patient mortality (2.3%, 1.87%, and 1.57% for low, intermediate, and high volume center, respectively, p <0.001) were significantly less with greater hospital volume but FTR (8.24%, 8.20%, and 6.12% for low, intermediate, and high volume center, respectively, p = 0.29) were the same in the three groups. Our results suggest that FTR does not explain the variation of in-hospital mortality in different hospital volumes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.amjcard.2018.05.020

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 18

Metadata

Authors
Ando, T., Adegbala, O., Villablanca, P. A., Shokr, M., Akintoye, E., Briasoulis, A., Takagi, H., Schreiber, T., Grines, C. L., & Afonso, L.
Venue
The American Journal of Cardiology
Publisher
Elsevier BV
Published
2018-09
Volume
122
Issue
5
Pages
828-832
ISSN
0002-9149 (ISSN-L)
OpenAlex
W2808230971
Cited by
18
References
0
FWCI
2.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Failure to Rescue, Hospital Volume, and In-Hospital Mortality After Transcatheter Aortic Valve Implantation. https://app.cochat.ai/papers/10.1016/j.amjcard.2018.05.020
The paper
Ando, T., Adegbala, O., Villablanca, P. A., Shokr, M., Akintoye, E., Briasoulis, A., Takagi, H., Schreiber, T., Grines, C. L., & Afonso, L. (2018). Failure to Rescue, Hospital Volume, and In-Hospital Mortality After Transcatheter Aortic Valve Implantation. The American Journal of Cardiology. https://doi.org/10.1016/j.amjcard.2018.05.020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.