Misclassification of Blood Pressure by Usual Measurement in Ambulatory Physician Practices
The DOI matches its Crossref record.
Abstract
BACKGROUND: Standardized measurement of blood pressure (BP) is widely recommended but rarely followed in usual clinical practice. METHODS: We compared the classification of hypertension status of 107 patients referred by family physicians for ambulatory BP monitoring (ABPM) and with elevated clinic BP when assessed by usual clinical office measurement, a trained hypertension research nurse using a standardized measurement protocol, or an ambulatory BP monitor. RESULTS: Usual clinic readings resulted in higher BP readings than those obtained by the research nurse: mean (95% confidence interval [CI]), 10.8 (8.0 to 13.6)/4.9 (2.9 to 6.9) mm Hg, the daytime ambulatory BP 7.7 (5.1 to 10.3)/5.1 (3.0 to 7.1), and the 24-h ambulatory BP 12.1 (9.6 to 14.6)/8.9 (6.9 to 10.9). The interpretation of whether the patient had a hypertensive versus normotensive reading in the usual clinic setting differed in 42% of patients relative to standardized nurse readings. CONCLUSIONS: Following standardized technique is important for correct classification of the BP status of patients. Use of usual or casual technique results in higher readings than standardized or ambulatory BP readings. This study indicates that significant improvement in the assessment of BP is required for diagnosis and optimal management of hypertension. Consideration strongly needs to be given to the development of alternative methods of assessing BP in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Self-citationNerenberg, K. A., Zarnke, K. B., Leung, A. A., Dasgupta, K., Butalia, S., McBrien, K., Harris, K. C., Nakhla, M., Cloutier, L., Gelfer, M., et al. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.02.022 · Cited by 573
Self-citationPadwal, R., Campbell, N. R. C., Schutte, A. E., Olsen, M. H., Delles, C., Etyang, A., Cruickshank, J. K., Stergiou, G., Rakotz, M. K., Wozniak, G., et al. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002112 · Cited by 108
“Time constraints and suboptimal technique leading topoorly performed auscultation are responsible formuchof this error [10,15].”
BackgroundSelf-citationRandom measurement error: Why worry? An example of cardiovascular risk factors
Brakenhoff, T. B., van Smeden, M., Visseren, F. L. J., & Groenwold, R. H. H. (2018) · PLOS ONE · doi:10.1371/journal.pone.0192298 · Cited by 52
Tang, O., Foti, K., Miller, E. R., Appel, L. J., & Juraschek, S. P. (2020) · American Journal of Hypertension · doi:10.1093/ajh/hpaa093 · Cited by 30
Metadata
- Authors
- CAMPBELL, N., CULLETON, B., & MCKAY, D.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-12
- Volume
- 18
- Issue
- 12
- Pages
- 1522-1527
- ISSN
- 0895-7061 (ISSN-L)
- OpenAlex
- W2091181518
- Cited by
- 69
- References
- 0
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.